Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

A simple modification of Greiner electronics selective analyser G300 permitting use of capillary blood samples

Grubb, A LU orcid ; Bolin, K and Jeppsson, B (1982) In Scandinavian Journal of Clinical and Laboratory Investigation 42(7). p.599-601
Abstract

A simple modification of Greiner electronics selective analyser G300 allowing direct transference of serum samples to the process tubes is described. The modified instrument permitted use of pediatric and capillary blood samples. Eight different capillary analyses were tested on the modified instrument and the results agreed with those obtained by the ordinary analytical macroprocedures of the instrument.

Please use this url to cite or link to this publication:
author
; and
organization
publishing date
type
Contribution to journal
publication status
published
keywords
Automation, Blood Chemical Analysis/instrumentation, Chemistry, Clinical/instrumentation, Electronics, Medical, Humans, Specimen Handling
in
Scandinavian Journal of Clinical and Laboratory Investigation
volume
42
issue
7
pages
599 - 601
publisher
Informa Healthcare
external identifiers
  • pmid:7156870
  • scopus:0019920432
ISSN
0036-5513
language
English
LU publication?
yes
id
957f6d8e-3a90-4526-95c5-c31fd1aa4f29
date added to LUP
2021-10-21 16:26:27
date last changed
2024-01-12 02:56:44
@article{957f6d8e-3a90-4526-95c5-c31fd1aa4f29,
  abstract     = {{<p>A simple modification of Greiner electronics selective analyser G300 allowing direct transference of serum samples to the process tubes is described. The modified instrument permitted use of pediatric and capillary blood samples. Eight different capillary analyses were tested on the modified instrument and the results agreed with those obtained by the ordinary analytical macroprocedures of the instrument.</p>}},
  author       = {{Grubb, A and Bolin, K and Jeppsson, B}},
  issn         = {{0036-5513}},
  keywords     = {{Automation; Blood Chemical Analysis/instrumentation; Chemistry, Clinical/instrumentation; Electronics, Medical; Humans; Specimen Handling}},
  language     = {{eng}},
  number       = {{7}},
  pages        = {{599--601}},
  publisher    = {{Informa Healthcare}},
  series       = {{Scandinavian Journal of Clinical and Laboratory Investigation}},
  title        = {{A simple modification of Greiner electronics selective analyser G300 permitting use of capillary blood samples}},
  volume       = {{42}},
  year         = {{1982}},
}