Stapling in thyroid surgery. A prospective study
(1992) In Annales Chirurgiae et Gynaecologiae 81(1). p.48-50- Abstract
In a prospective study, resection of the thyroid gland by means of a linear stapling device was compared with the conventional resection technique in 12 consecutive patients with thyreotoxicosis. The median time for resection of the stapled lobe was shorter than for the conventionally resected right lobe, although the difference was not statistically significant. The median preoperative bleeding during resection of the stapled left lobe was 42 ml (range 15-126 ml), compared with 78 ml (range 34-247 ml) during the conventional resection of the right lobe (P less than 0.05). Median postoperative bleeding was somewhat less from the stapled side compared with the conventionally resected side, but did not reach statistical significance. The... (More)
In a prospective study, resection of the thyroid gland by means of a linear stapling device was compared with the conventional resection technique in 12 consecutive patients with thyreotoxicosis. The median time for resection of the stapled lobe was shorter than for the conventionally resected right lobe, although the difference was not statistically significant. The median preoperative bleeding during resection of the stapled left lobe was 42 ml (range 15-126 ml), compared with 78 ml (range 34-247 ml) during the conventional resection of the right lobe (P less than 0.05). Median postoperative bleeding was somewhat less from the stapled side compared with the conventionally resected side, but did not reach statistical significance. The study thus demonstrates the feasibility of carrying out resection of the thyroid gland with a linear stapling device. The technique minimizes peroperative bleeding. It could therefore be used in thyroid surgery.
(Less)
- author
- Bergenfelz, A LU ; Ingvar, C LU and Månsson, Bertil
- organization
- publishing date
- 1992
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- Adult, Blood Loss, Surgical, Female, Goiter, Nodular, Humans, Male, Middle Aged, Postoperative Complications, Prospective Studies, Surgical Staplers, Thyroidectomy, Thyrotoxicosis, Comparative Study, Journal Article
- in
- Annales Chirurgiae et Gynaecologiae
- volume
- 81
- issue
- 1
- pages
- 3 pages
- publisher
- Finnish Surgical Society
- external identifiers
-
- pmid:1622052
- scopus:0026763136
- ISSN
- 0355-9521
- language
- English
- LU publication?
- yes
- id
- 981aac3f-4e8a-46d1-b134-da94f5631519
- date added to LUP
- 2017-05-10 13:44:13
- date last changed
- 2024-01-13 20:34:52
@article{981aac3f-4e8a-46d1-b134-da94f5631519, abstract = {{<p>In a prospective study, resection of the thyroid gland by means of a linear stapling device was compared with the conventional resection technique in 12 consecutive patients with thyreotoxicosis. The median time for resection of the stapled lobe was shorter than for the conventionally resected right lobe, although the difference was not statistically significant. The median preoperative bleeding during resection of the stapled left lobe was 42 ml (range 15-126 ml), compared with 78 ml (range 34-247 ml) during the conventional resection of the right lobe (P less than 0.05). Median postoperative bleeding was somewhat less from the stapled side compared with the conventionally resected side, but did not reach statistical significance. The study thus demonstrates the feasibility of carrying out resection of the thyroid gland with a linear stapling device. The technique minimizes peroperative bleeding. It could therefore be used in thyroid surgery.</p>}}, author = {{Bergenfelz, A and Ingvar, C and Månsson, Bertil}}, issn = {{0355-9521}}, keywords = {{Adult; Blood Loss, Surgical; Female; Goiter, Nodular; Humans; Male; Middle Aged; Postoperative Complications; Prospective Studies; Surgical Staplers; Thyroidectomy; Thyrotoxicosis; Comparative Study; Journal Article}}, language = {{eng}}, number = {{1}}, pages = {{48--50}}, publisher = {{Finnish Surgical Society}}, series = {{Annales Chirurgiae et Gynaecologiae}}, title = {{Stapling in thyroid surgery. A prospective study}}, volume = {{81}}, year = {{1992}}, }