In vivo testing of the protection provided by non-latex gloves against a 2-hydroxyethyl methacrylate-containing acetone-based dentin-bonding product

Andersson, T ; Bruze, Magnus LU ; Gruvberger, Birgitta LU and Björkner, Bert LU (2000) In Acta Dermato-Venereologica 80(6). p.435-437
Abstract
In dentistry, allergic contact dermatitis to acrylates and allergic contact urticaria to latex are important occupational hazards. There is a need to identify non-latex gloves which are suitable for dental work but at the same time provide adequate protection against acrylate monomers. In a previous study, a new open-chamber system was used for testing the in vivo protection of 6 different gloves against an acrylate-containing ethanol-based dental adhesive. A nitrile glove gave the best protection among the gloves suitable for dental work. In the present study, the test model was used to investigate the in vivo protection of 7 non-latex gloves against a dental bonding product containing 2-hydroxyethyl methacrylate (2-HEMA) in an... (More)
In dentistry, allergic contact dermatitis to acrylates and allergic contact urticaria to latex are important occupational hazards. There is a need to identify non-latex gloves which are suitable for dental work but at the same time provide adequate protection against acrylate monomers. In a previous study, a new open-chamber system was used for testing the in vivo protection of 6 different gloves against an acrylate-containing ethanol-based dental adhesive. A nitrile glove gave the best protection among the gloves suitable for dental work. In the present study, the test model was used to investigate the in vivo protection of 7 non-latex gloves against a dental bonding product containing 2-hydroxyethyl methacrylate (2-HEMA) in an acetone/water vehicle. Eight 2-HEMA-allergic patients participated. Two neoprene gloves gave the best protection. The protection of the poorest glove was comparable to that of the positive control (no glove). The study produced in vivo data useful in the implementation of individual preventative measures against contact allergy to acrylates. (Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Acta Dermato-Venereologica
volume
80
issue
6
pages
435 - 437
publisher
Medical Journals Limited
external identifiers
  • pmid:11243638
  • scopus:0034486916
ISSN
1651-2057
DOI
10.1080/000155500300012891
language
English
LU publication?
yes
additional info
The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Occupational and Environmental Dermatology Unit (013241310), Pediatrics/Urology/Gynecology/Endocrinology (013240400)
id
99eb1cc8-6d5e-4d05-aed1-6571c5867f4a (old id 1117472)
date added to LUP
2016-04-01 15:39:18
date last changed
2022-04-30 08:03:47
@article{99eb1cc8-6d5e-4d05-aed1-6571c5867f4a,
  abstract     = {{In dentistry, allergic contact dermatitis to acrylates and allergic contact urticaria to latex are important occupational hazards. There is a need to identify non-latex gloves which are suitable for dental work but at the same time provide adequate protection against acrylate monomers. In a previous study, a new open-chamber system was used for testing the in vivo protection of 6 different gloves against an acrylate-containing ethanol-based dental adhesive. A nitrile glove gave the best protection among the gloves suitable for dental work. In the present study, the test model was used to investigate the in vivo protection of 7 non-latex gloves against a dental bonding product containing 2-hydroxyethyl methacrylate (2-HEMA) in an acetone/water vehicle. Eight 2-HEMA-allergic patients participated. Two neoprene gloves gave the best protection. The protection of the poorest glove was comparable to that of the positive control (no glove). The study produced in vivo data useful in the implementation of individual preventative measures against contact allergy to acrylates.}},
  author       = {{Andersson, T and Bruze, Magnus and Gruvberger, Birgitta and Björkner, Bert}},
  issn         = {{1651-2057}},
  language     = {{eng}},
  number       = {{6}},
  pages        = {{435--437}},
  publisher    = {{Medical Journals Limited}},
  series       = {{Acta Dermato-Venereologica}},
  title        = {{In vivo testing of the protection provided by non-latex gloves against a 2-hydroxyethyl methacrylate-containing acetone-based dentin-bonding product}},
  url          = {{http://dx.doi.org/10.1080/000155500300012891}},
  doi          = {{10.1080/000155500300012891}},
  volume       = {{80}},
  year         = {{2000}},
}