Neutron reflectometry with the Multi-Blade 10B-based detector
(2018) In Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences 474(2216).- Abstract
The Multi-Blade is a boron-10-based gaseous detector developed for neutron reflectometry instruments at the European Spallation Source in Sweden. The main challenges for neutron reflectometry detectors are the instantaneous counting rate and spatial resolution. The Multi-Blade has been tested on the CRISP reflectometer at the ISIS Neutron and Muon Source in the UK. A campaign of scientific measurements has been performed to study the Multi-Blade response in real instrumental conditions. The results of these tests are discussed in this paper.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/9a9ae19b-c05e-4e56-9d51-9034c6c7ae4d
- author
- organization
- publishing date
- 2018-08-22
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- Boron-10, Gaseous detectors, Neutron detectors (cold and thermal neutrons), Neutron reflectometry, Neutron scattering
- in
- Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences
- volume
- 474
- issue
- 2216
- article number
- 20180266
- publisher
- Royal Society Publishing
- external identifiers
-
- scopus:85053128607
- pmid:30220868
- ISSN
- 1364-5021
- DOI
- 10.1098/rspa.2018.0266
- project
- H2020: BrightnESS - Building a research infrastructure and synergies for highest scientific impact on ESS
- Multi-Blade: the Boron-10-based neutron detector for high intensity neutron reflectometry at ESS
- language
- English
- LU publication?
- yes
- id
- 9a9ae19b-c05e-4e56-9d51-9034c6c7ae4d
- alternative location
- https://arxiv.org/pdf/1804.03962.pdf
- date added to LUP
- 2018-04-19 10:14:07
- date last changed
- 2023-04-08 11:05:30
@article{9a9ae19b-c05e-4e56-9d51-9034c6c7ae4d, abstract = {{<p>The Multi-Blade is a boron-10-based gaseous detector developed for neutron reflectometry instruments at the European Spallation Source in Sweden. The main challenges for neutron reflectometry detectors are the instantaneous counting rate and spatial resolution. The Multi-Blade has been tested on the CRISP reflectometer at the ISIS Neutron and Muon Source in the UK. A campaign of scientific measurements has been performed to study the Multi-Blade response in real instrumental conditions. The results of these tests are discussed in this paper.</p>}}, author = {{Mauri, G. and Messi, F. and Anastasopoulos, M. and Arnold, T. and Glavic, A. and Höglund, C. and Ilves, T. and Lopez Higuera, I. and Pazmandi, P. and Raspino, D. and Robinson, L. and Schmidt, S. and Svensson, P. and Varga, D. and Hall-Wilton, R. and Piscitelli, F.}}, issn = {{1364-5021}}, keywords = {{Boron-10; Gaseous detectors; Neutron detectors (cold and thermal neutrons); Neutron reflectometry; Neutron scattering}}, language = {{eng}}, month = {{08}}, number = {{2216}}, publisher = {{Royal Society Publishing}}, series = {{Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences}}, title = {{Neutron reflectometry with the Multi-Blade 10B-based detector}}, url = {{http://dx.doi.org/10.1098/rspa.2018.0266}}, doi = {{10.1098/rspa.2018.0266}}, volume = {{474}}, year = {{2018}}, }