Average force along unbonded tendons: a field study at nuclear reactor containments in Sweden

Anderson, Patrick LU ; Berglund, LE and Gustavsson, J (2005) In Nuclear Engineering and Design 235(1). p.91-100
Abstract
The tightness and integrity of all Swedish reactor containments depend directly and indirectly on the function of the post-tensioned system. The tendon force in containments with unbonded tendons is followed up at regular in-service inspections (ISI) to ensure that the remaining force is sufficient. At the inspections, the tendon force is measured with so-called lift-off technique, where a jack is used to lift the end anchor. The interpretation of the measuring results is not obvious. One difficulty, which affects all tendons to different extents, is the influence of friction between the tendon and duct. This influence can cause a redistribution of force along the tendons after the original tensioning. The ordinary lift-off method only... (More)
The tightness and integrity of all Swedish reactor containments depend directly and indirectly on the function of the post-tensioned system. The tendon force in containments with unbonded tendons is followed up at regular in-service inspections (ISI) to ensure that the remaining force is sufficient. At the inspections, the tendon force is measured with so-called lift-off technique, where a jack is used to lift the end anchor. The interpretation of the measuring results is not obvious. One difficulty, which affects all tendons to different extents, is the influence of friction between the tendon and duct. This influence can cause a redistribution of force along the tendons after the original tensioning. The ordinary lift-off method only measures the force at the end of the tendon, which not always represents the change of force in the rest of the tendon. A method for measuring average force along a tendon is presented in this article. In this method, the elongation of the tendon is measured when the jack force is increased to a reference level with known force distribution. Measuring results from the latest ISI in Sweden show that the end force has decreased more than the average force, especially for long tendons with high influence of friction. (Less)
Please use this url to cite or link to this publication:
author
; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Nuclear Engineering and Design
volume
235
issue
1
pages
91 - 100
publisher
Elsevier
external identifiers
  • wos:000226452200007
  • scopus:11144232040
ISSN
1872-759X
DOI
10.1016/j.nucengdes.2004.08.037
language
English
LU publication?
yes
id
9c7c8d64-ae3e-4ab3-80de-940cfaf47274 (old id 255145)
date added to LUP
2016-04-01 12:37:21
date last changed
2022-01-27 07:34:00
@article{9c7c8d64-ae3e-4ab3-80de-940cfaf47274,
  abstract     = {{The tightness and integrity of all Swedish reactor containments depend directly and indirectly on the function of the post-tensioned system. The tendon force in containments with unbonded tendons is followed up at regular in-service inspections (ISI) to ensure that the remaining force is sufficient. At the inspections, the tendon force is measured with so-called lift-off technique, where a jack is used to lift the end anchor. The interpretation of the measuring results is not obvious. One difficulty, which affects all tendons to different extents, is the influence of friction between the tendon and duct. This influence can cause a redistribution of force along the tendons after the original tensioning. The ordinary lift-off method only measures the force at the end of the tendon, which not always represents the change of force in the rest of the tendon. A method for measuring average force along a tendon is presented in this article. In this method, the elongation of the tendon is measured when the jack force is increased to a reference level with known force distribution. Measuring results from the latest ISI in Sweden show that the end force has decreased more than the average force, especially for long tendons with high influence of friction.}},
  author       = {{Anderson, Patrick and Berglund, LE and Gustavsson, J}},
  issn         = {{1872-759X}},
  language     = {{eng}},
  number       = {{1}},
  pages        = {{91--100}},
  publisher    = {{Elsevier}},
  series       = {{Nuclear Engineering and Design}},
  title        = {{Average force along unbonded tendons: a field study at nuclear reactor containments in Sweden}},
  url          = {{http://dx.doi.org/10.1016/j.nucengdes.2004.08.037}},
  doi          = {{10.1016/j.nucengdes.2004.08.037}},
  volume       = {{235}},
  year         = {{2005}},
}