Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Tracking of geological structures and detection of hydrothermal intrusion by geo-electrical methods in the highlands of Bolivia

Gómez, Etzar LU ; Svensson, Emil ; Dahlin, Torleif LU ; Barmen, Gerhard LU and Rosberg, Jan Erik LU (2019) In Journal of South American Earth Sciences 91. p.214-226
Abstract

Oruro city in the Bolivian highlands depends solely on groundwater to supply domestic consumption and irrigation. The top porous aquifer currently exploited is not fully understood in aspects like geometry, hydrogeological properties and interaction with other aquifers in the region. Recent studies detected traces of fractures in the bedrock beneath the porous aquifer; these geological structures seem to be part of a fractured aquifer in contact with thermal sources. The present study aims to fill the gap between those recently detected fractures and the well-mapped fault system to the east of the study area and identify hydrothermal flows by using geo-electrical methods like Electrical Resistivity Tomography and Transient... (More)

Oruro city in the Bolivian highlands depends solely on groundwater to supply domestic consumption and irrigation. The top porous aquifer currently exploited is not fully understood in aspects like geometry, hydrogeological properties and interaction with other aquifers in the region. Recent studies detected traces of fractures in the bedrock beneath the porous aquifer; these geological structures seem to be part of a fractured aquifer in contact with thermal sources. The present study aims to fill the gap between those recently detected fractures and the well-mapped fault system to the east of the study area and identify hydrothermal flows by using geo-electrical methods like Electrical Resistivity Tomography and Transient Electromagnetic soundings. Thirteen tomographic lines, placed transversely to the direction of three main faults, were meant to identify prolongations of those structures by tracking distinctive low resistivity in sectors where saline water saturates the subsoil. This type of water is also present in some hot springs near Capachos, where hydrothermal flows discharge under artesian conditions. Two of the investigated faults seem extending to the northwest, in agreement with the expected linkage towards the recently detected fractures. These two faults appear to reach a volcanic formation since the hydrothermal flows, going mainly upwards, align with their strikes. The remaining fault seems not to be connected to any hydrothermal source. The study presents new information, data and interpretations intending to improve the knowledge about the geological structures in a sensitive part of the local aquifer system.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Altiplano, Bolivia, Electrical resistivity tomography, Faults, Transient electromagnetic sounding
in
Journal of South American Earth Sciences
volume
91
pages
13 pages
publisher
Elsevier
external identifiers
  • scopus:85061995083
ISSN
0895-9811
DOI
10.1016/j.jsames.2019.02.002
language
English
LU publication?
yes
id
a64dfff3-a449-44dd-8e11-75ffe9b8716d
date added to LUP
2019-03-05 14:33:26
date last changed
2022-04-10 06:33:46
@article{a64dfff3-a449-44dd-8e11-75ffe9b8716d,
  abstract     = {{<p>Oruro city in the Bolivian highlands depends solely on groundwater to supply domestic consumption and irrigation. The top porous aquifer currently exploited is not fully understood in aspects like geometry, hydrogeological properties and interaction with other aquifers in the region. Recent studies detected traces of fractures in the bedrock beneath the porous aquifer; these geological structures seem to be part of a fractured aquifer in contact with thermal sources. The present study aims to fill the gap between those recently detected fractures and the well-mapped fault system to the east of the study area and identify hydrothermal flows by using geo-electrical methods like Electrical Resistivity Tomography and Transient Electromagnetic soundings. Thirteen tomographic lines, placed transversely to the direction of three main faults, were meant to identify prolongations of those structures by tracking distinctive low resistivity in sectors where saline water saturates the subsoil. This type of water is also present in some hot springs near Capachos, where hydrothermal flows discharge under artesian conditions. Two of the investigated faults seem extending to the northwest, in agreement with the expected linkage towards the recently detected fractures. These two faults appear to reach a volcanic formation since the hydrothermal flows, going mainly upwards, align with their strikes. The remaining fault seems not to be connected to any hydrothermal source. The study presents new information, data and interpretations intending to improve the knowledge about the geological structures in a sensitive part of the local aquifer system.</p>}},
  author       = {{Gómez, Etzar and Svensson, Emil and Dahlin, Torleif and Barmen, Gerhard and Rosberg, Jan Erik}},
  issn         = {{0895-9811}},
  keywords     = {{Altiplano; Bolivia; Electrical resistivity tomography; Faults; Transient electromagnetic sounding}},
  language     = {{eng}},
  pages        = {{214--226}},
  publisher    = {{Elsevier}},
  series       = {{Journal of South American Earth Sciences}},
  title        = {{Tracking of geological structures and detection of hydrothermal intrusion by geo-electrical methods in the highlands of Bolivia}},
  url          = {{http://dx.doi.org/10.1016/j.jsames.2019.02.002}},
  doi          = {{10.1016/j.jsames.2019.02.002}},
  volume       = {{91}},
  year         = {{2019}},
}