This study employed microCT to investigate whether image resolution affects bone structural parameters differently in healthy normal and osteoporotic trabecular bone. With increasing image voxel size, the originally detected differences between sample groups diminished. The results suggest that structural differences may not be reliably detected with clinical scanners.
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; and
publishing date
type
Contribution to journal
publication status
published
subject
in
Osteoporosis International
volume
22
issue
1
pages
167 - 177
publisher
Springer
external identifiers
  • scopus:78651477793
  • pmid:20349043
ISSN
1433-2965
DOI
10.1007/s00198-010-1219-0
language
English
LU publication?
no
id
a86f209a-de49-4891-8b7c-180c0591a9f5 (old id 2277117)
date added to LUP
2016-04-01 11:11:02
date last changed
2023-08-31 20:26:20
@article{a86f209a-de49-4891-8b7c-180c0591a9f5,
  abstract     = {{<b>Abstract in Undetermined</b><br/><br>
This study employed microCT to investigate whether image resolution affects bone structural parameters differently in healthy normal and osteoporotic trabecular bone. With increasing image voxel size, the originally detected differences between sample groups diminished. The results suggest that structural differences may not be reliably detected with clinical scanners.}},
  author       = {{Isaksson, Hanna and Töyräs, Juha and Hakulinen, Mikko and Tamminen, Inari and Aula, Antti and Julkunen, Petro and Kröger, Heikki and Jurvelin, Jukka}},
  issn         = {{1433-2965}},
  language     = {{eng}},
  number       = {{1}},
  pages        = {{167--177}},
  publisher    = {{Springer}},
  series       = {{Osteoporosis International}},
  title        = {{Structural Parameters determined by microCT in normal and osteoporotic human trabecular Bone are Affected Differently by image resolution}},
  url          = {{http://dx.doi.org/10.1007/s00198-010-1219-0}},
  doi          = {{10.1007/s00198-010-1219-0}},
  volume       = {{22}},
  year         = {{2011}},
}