Effect of an upstream unconnected bulge on film cooling
(2017) In Chemical Engineering Transactions 61. p.223-228- Abstract
Film cooling technology is commonly used in a cooling system of gas turbines. For different upstream bulge configurations, the unconnected and connected configurations were used to investigate the film cooling effectiveness and downstream dimensionless temperature distributions in this paper. Moreover, the effect of the blowing ratio was analyzed by using the computational fluid mechanics. The results show that a bulge configuration located upstream the film hole shows more uniform film cooling effectiveness, resulting in an enhancement of the lateral cooling effectiveness. The film cooling effectiveness for the unconnected bulge configuration slightly decreases along the centerline.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/ad8393c1-5be5-4f36-8e91-111e0837a2de
- author
- Li, Qianqian ; Wang, Jin LU ; Min, Chunhua ; Tian, Ke ; Tian, Liting and Sundén, Bengt LU
- organization
- publishing date
- 2017
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Chemical Engineering Transactions
- volume
- 61
- pages
- 6 pages
- publisher
- AIDIC - associazione italiana di ingegneria chimica
- external identifiers
-
- scopus:85030749301
- ISSN
- 1974-9791
- DOI
- 10.3303/CET1761035
- language
- English
- LU publication?
- yes
- id
- ad8393c1-5be5-4f36-8e91-111e0837a2de
- date added to LUP
- 2017-10-18 09:06:28
- date last changed
- 2022-04-25 03:20:13
@article{ad8393c1-5be5-4f36-8e91-111e0837a2de, abstract = {{<p>Film cooling technology is commonly used in a cooling system of gas turbines. For different upstream bulge configurations, the unconnected and connected configurations were used to investigate the film cooling effectiveness and downstream dimensionless temperature distributions in this paper. Moreover, the effect of the blowing ratio was analyzed by using the computational fluid mechanics. The results show that a bulge configuration located upstream the film hole shows more uniform film cooling effectiveness, resulting in an enhancement of the lateral cooling effectiveness. The film cooling effectiveness for the unconnected bulge configuration slightly decreases along the centerline.</p>}}, author = {{Li, Qianqian and Wang, Jin and Min, Chunhua and Tian, Ke and Tian, Liting and Sundén, Bengt}}, issn = {{1974-9791}}, language = {{eng}}, pages = {{223--228}}, publisher = {{AIDIC - associazione italiana di ingegneria chimica}}, series = {{Chemical Engineering Transactions}}, title = {{Effect of an upstream unconnected bulge on film cooling}}, url = {{http://dx.doi.org/10.3303/CET1761035}}, doi = {{10.3303/CET1761035}}, volume = {{61}}, year = {{2017}}, }