On-line Heart Rate Monitoring Using the Extra-corporeal Pressure Sensors of a Dialysis Machine
(2012) Biomedical engineering – 2012- Abstract
- Heart rate can be extracted from the extracorporeal venous pressure signal of a dialysis machine. The results are of comparable accuracy and reliability to the ones obtained by the PPG reference signal from a pulse oximeter. Difficulties that occur during heart rate estimation were determined, and some can be overcome by a slight adjustment of blood flow rate. The described techniques, after being implemented into the dialysis machines, would help to improve current hemodialysis safety throughout the treatment by on-line monitoring of the cardiac activity.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/4622356
- author
- Holmer, Mattias LU ; Grigonyte, Egle LU ; Olde, Bo ; Sternby, Jan ; Segelmark, Mårten LU ; Solem, Kristian LU and Sörnmo, Leif LU
- organization
- publishing date
- 2012
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- host publication
- Biomedical engineering – 2012 : proceedings of international conference
- conference name
- Biomedical engineering – 2012
- conference location
- Kaunas, Lithuania
- conference dates
- 2012-10-25 - 2012-10-26
- ISSN
- 2029-3380
- language
- English
- LU publication?
- yes
- id
- afdbd495-0f3f-4908-983c-c73fe9882e99 (old id 4622356)
- date added to LUP
- 2016-04-04 09:29:28
- date last changed
- 2018-11-21 20:53:28
@inproceedings{afdbd495-0f3f-4908-983c-c73fe9882e99, abstract = {{Heart rate can be extracted from the extracorporeal venous pressure signal of a dialysis machine. The results are of comparable accuracy and reliability to the ones obtained by the PPG reference signal from a pulse oximeter. Difficulties that occur during heart rate estimation were determined, and some can be overcome by a slight adjustment of blood flow rate. The described techniques, after being implemented into the dialysis machines, would help to improve current hemodialysis safety throughout the treatment by on-line monitoring of the cardiac activity.}}, author = {{Holmer, Mattias and Grigonyte, Egle and Olde, Bo and Sternby, Jan and Segelmark, Mårten and Solem, Kristian and Sörnmo, Leif}}, booktitle = {{Biomedical engineering – 2012 : proceedings of international conference}}, issn = {{2029-3380}}, language = {{eng}}, title = {{On-line Heart Rate Monitoring Using the Extra-corporeal Pressure Sensors of a Dialysis Machine}}, year = {{2012}}, }