Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Gadolinium neutron capture brachytherapy (GdNCB), a new treatment method for intravascular brachytherapy

Enger, Shirin A. ; Rezaei, Arash ; Munck Af Rosenschöld, Per LU orcid and Lundqvist, Hans (2006) In Medical Physics 33(1). p.46-51
Abstract

Restenosis is a major problem after balloon angioplasty and stent implantation. The aim of this study is to introduce gadolinium neutron capture brachytherapy (GdNCB) as a suitable modality for treatment of stenosis. The utility of GdNCB in intravascular brachytherapy (IVBT) of stent stenosis is investigated by using the GEANT4 and MCNP4B Monte Carlo radiation transport codes. To study capture rate, Kerma, absorbed dose and absorbed dose rate around a Gd-containing stent activated with neutrons, a 30 mm long, 5 mm diameter gadolinium foil is chosen. The input data is a neutron spectrum used for clinical neutron capture therapy in Studsvik, Sweden. Thermal neutron capture in gadolinium yields a spectrum of high-energy gamma photons,... (More)

Restenosis is a major problem after balloon angioplasty and stent implantation. The aim of this study is to introduce gadolinium neutron capture brachytherapy (GdNCB) as a suitable modality for treatment of stenosis. The utility of GdNCB in intravascular brachytherapy (IVBT) of stent stenosis is investigated by using the GEANT4 and MCNP4B Monte Carlo radiation transport codes. To study capture rate, Kerma, absorbed dose and absorbed dose rate around a Gd-containing stent activated with neutrons, a 30 mm long, 5 mm diameter gadolinium foil is chosen. The input data is a neutron spectrum used for clinical neutron capture therapy in Studsvik, Sweden. Thermal neutron capture in gadolinium yields a spectrum of high-energy gamma photons, which due to the build-up effect gives an almost flat dose delivery pattern to the first 4 mm around the stent. The absorbed dose rate is 1.33 Gy/min, 0.25 mm from the stent surface while the dose to normal tissue is in order of 0.22 Gy/min, i.e., a factor of 6 lower. To spare normal tissue further fractionation of the dose is also possible. The capture rate is relatively high at both ends of the foil. The dose distribution from gamma and charge particle radiation at the edges and inside the stent contributes to a nonuniform dose distribution. This will lead to higher doses to the surrounding tissue and may prevent stent edge and in-stent restenosis. The position of the stent can be verified and corrected by the treatment plan prior to activation. Activation of the stent by an external neutron field can be performed days after catherization when the target cells start to proliferate and can be expected to be more radiation sensitive. Another advantage of the nonradioactive gadolinium stent is the possibility to avoid radiation hazard to personnel.

(Less)
Please use this url to cite or link to this publication:
author
; ; and
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Gadolinium neutron capture brachytherapy, Intravascular brachytherapy, Radioactive stent, Restenosis
in
Medical Physics
volume
33
issue
1
pages
46 - 51
publisher
American Association of Physicists in Medicine
external identifiers
  • wos:000234772100007
  • pmid:16485408
  • scopus:31044447772
  • pmid:16485408
ISSN
0094-2405
DOI
10.1118/1.2146050
language
English
LU publication?
no
id
b02090a0-8a91-450f-8d6d-19c06dd52486 (old id 419713)
date added to LUP
2016-04-01 16:28:48
date last changed
2024-01-11 08:50:47
@article{b02090a0-8a91-450f-8d6d-19c06dd52486,
  abstract     = {{<p>Restenosis is a major problem after balloon angioplasty and stent implantation. The aim of this study is to introduce gadolinium neutron capture brachytherapy (GdNCB) as a suitable modality for treatment of stenosis. The utility of GdNCB in intravascular brachytherapy (IVBT) of stent stenosis is investigated by using the GEANT4 and MCNP4B Monte Carlo radiation transport codes. To study capture rate, Kerma, absorbed dose and absorbed dose rate around a Gd-containing stent activated with neutrons, a 30 mm long, 5 mm diameter gadolinium foil is chosen. The input data is a neutron spectrum used for clinical neutron capture therapy in Studsvik, Sweden. Thermal neutron capture in gadolinium yields a spectrum of high-energy gamma photons, which due to the build-up effect gives an almost flat dose delivery pattern to the first 4 mm around the stent. The absorbed dose rate is 1.33 Gy/min, 0.25 mm from the stent surface while the dose to normal tissue is in order of 0.22 Gy/min, i.e., a factor of 6 lower. To spare normal tissue further fractionation of the dose is also possible. The capture rate is relatively high at both ends of the foil. The dose distribution from gamma and charge particle radiation at the edges and inside the stent contributes to a nonuniform dose distribution. This will lead to higher doses to the surrounding tissue and may prevent stent edge and in-stent restenosis. The position of the stent can be verified and corrected by the treatment plan prior to activation. Activation of the stent by an external neutron field can be performed days after catherization when the target cells start to proliferate and can be expected to be more radiation sensitive. Another advantage of the nonradioactive gadolinium stent is the possibility to avoid radiation hazard to personnel.</p>}},
  author       = {{Enger, Shirin A. and Rezaei, Arash and Munck Af Rosenschöld, Per and Lundqvist, Hans}},
  issn         = {{0094-2405}},
  keywords     = {{Gadolinium neutron capture brachytherapy; Intravascular brachytherapy; Radioactive stent; Restenosis}},
  language     = {{eng}},
  number       = {{1}},
  pages        = {{46--51}},
  publisher    = {{American Association of Physicists in Medicine}},
  series       = {{Medical Physics}},
  title        = {{Gadolinium neutron capture brachytherapy (GdNCB), a new treatment method for intravascular brachytherapy}},
  url          = {{http://dx.doi.org/10.1118/1.2146050}},
  doi          = {{10.1118/1.2146050}},
  volume       = {{33}},
  year         = {{2006}},
}