Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Kaonic-Atom X-ray Spectroscopy with Superconducting Microcalorimeters

Hashimoto, T. ; Bazzi, M. ; Bennett, D. A. ; Berucci, C. ; Bosnar, D. ; Curceanu, C. ; Doriese, W. B. ; Fowler, J. W. ; Fujioka, H. and Guaraldo, C. , et al. (2017) 17.
Abstract
We will measure kaonic helium X-rays using transition-edge-sensor microcalorimeters, TES, in the J-PARC hadron experimental facility. To demonstrate the feasibility of the experiment, we performed a measurement of pionic carbon X-rays at PSI, where an excellent FWHM energy resolution of 7 eV at 6.4 keV was achieved. We also evaluated the expected TES performance in the kaon beam at J-PARC. The simulation results show that the TES spectrometer would work with a good energy resolution, and clear peaks of kaonic helium X-rays would be observed on a reasonably suppressed background.
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; ; and , et al. (More)
; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; and (Less)
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
host publication
Proceedings of the 12th International Conference on Hypernuclear and Strange Particle Physics (HYP2015)
editor
Tamura, Hirokazu
volume
17
pages
4 pages
ISBN
978-4-89027-122-1
DOI
10.7566/JPSCP.17.072001
language
English
LU publication?
yes
id
b1a81cd2-1481-46a6-8c1f-3c03182139a3
date added to LUP
2018-08-01 14:23:54
date last changed
2019-02-11 17:48:30
@inproceedings{b1a81cd2-1481-46a6-8c1f-3c03182139a3,
  abstract     = {{We will measure kaonic helium X-rays using transition-edge-sensor microcalorimeters, TES, in the J-PARC hadron experimental facility. To demonstrate the feasibility of the experiment, we performed a measurement of pionic carbon X-rays at PSI, where an excellent FWHM energy resolution of 7 eV at 6.4 keV was achieved. We also evaluated the expected TES performance in the kaon beam at J-PARC. The simulation results show that the TES spectrometer would work with a good energy resolution, and clear peaks of kaonic helium X-rays would be observed on a reasonably suppressed background.}},
  author       = {{Hashimoto, T. and Bazzi, M. and Bennett, D. A. and Berucci, C. and Bosnar, D. and Curceanu, C. and Doriese, W. B. and Fowler, J. W. and Fujioka, H. and Guaraldo, C. and Gustafsson, F. Parnefjord and Hayano, R. S. and Hays-wehle, J. P. and Hilton, G. C. and Hiraiwa, T. and Iio, M. and Iliescu, M. and Ishimoto, S. and Itahashi, K. and Iwasaki, M. and Ma, Y. and Noumi, H. and O’neil, G. C. and Ohnishi, H. and Okada, S. and Outa, H. and Piscicchia, K. and Reintsema, C. D. and Sada, Y. and Sakuma, F. and Sato, M. and Schmidt, D. R. and Scordo, A. and Sekimoto, M. and Shi, H. and Sirghi, D. and Sirghi, F. and Suzuki, K. and Swetz, D. S. and Tanida, K. and Tatsuno, H. and Tokuda, M. and Uhlig, J. and Ullom, J. N. and Yamada, S. and Yamazaki, T. and Zmeskal, J.}},
  booktitle    = {{Proceedings of the 12th International Conference on Hypernuclear and Strange Particle Physics (HYP2015)}},
  editor       = {{Tamura, Hirokazu}},
  isbn         = {{978-4-89027-122-1}},
  language     = {{eng}},
  month        = {{07}},
  title        = {{Kaonic-Atom X-ray Spectroscopy with Superconducting Microcalorimeters}},
  url          = {{http://dx.doi.org/10.7566/JPSCP.17.072001}},
  doi          = {{10.7566/JPSCP.17.072001}},
  volume       = {{17}},
  year         = {{2017}},
}