A non-affinity-dependent high-resolution mass spectrometry method for detecting and typing monoclonal free light immunoglobulin chains

Bengtson, Per LU and Förnvik Jonsson, Magnus LU orcid (2025) In Journal of Mass Spectrometry and Advances in the Clinical Lab 38. p.88-96
Abstract

Background: Detecting and monitoring monoclonal free light immunoglobulin chains in serum is important for managing patients with B-cell neoplasms. Established methods have relied on immunochemistry, with monoclonality determined through an abnormal ratio of free kappa and lambda chains and an increased concentration of the involved chain. This indirect approach has limitations. Mass spectrometric methods that directly demonstrate the monoclonal fraction have been described; however, all reported approaches so far are affinity-dependent. The aim of this study was to develop a non–affinity-dependent high-resolution mass spectrometry (HRMS) method. Methods: Samples were prepared using ultrafiltration, then separated by reversed-phase... (More)

Background: Detecting and monitoring monoclonal free light immunoglobulin chains in serum is important for managing patients with B-cell neoplasms. Established methods have relied on immunochemistry, with monoclonality determined through an abnormal ratio of free kappa and lambda chains and an increased concentration of the involved chain. This indirect approach has limitations. Mass spectrometric methods that directly demonstrate the monoclonal fraction have been described; however, all reported approaches so far are affinity-dependent. The aim of this study was to develop a non–affinity-dependent high-resolution mass spectrometry (HRMS) method. Methods: Samples were prepared using ultrafiltration, then separated by reversed-phase liquid chromatography and analyzed by HRMS. The performance of the method was evaluated, including a comparison with a nephelometric immunoassay for free light immunoglobulin chains. Results: Concordance between HRMS and the immunoassay in classifying a sample as containing a monoclonal free light chain or not was 84% (based on 100 unique patient samples). HRMS identified more samples containing a monoclonal free light chain than the immunoassay. Some monoclonal fractions were glycosylated and/or cysteinylated. Imprecision (CV) for the concentration measurements of monoclonal fractions ranged from 10 to 14%. Conclusions: The HRMS method presented can detect, isotype, and semi-quantify monoclonal monomeric and dimeric light chains in serum, as well as demonstrate post-translational modifications. It is a selective, non–affinity-dependent method with a simple workflow that has the potential to become a valuable tool in the management of B-cell diseases.

(Less)
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
DDA, Deconvolution, FLC, FLC-immunoassay, LC-HRMS, Mass spectrometry, Monoclonal immunoglobulin, MS, Ultrafiltration
in
Journal of Mass Spectrometry and Advances in the Clinical Lab
volume
38
pages
9 pages
external identifiers
  • scopus:105023394565
ISSN
2667-1468
DOI
10.1016/j.jmsacl.2025.11.004
language
English
LU publication?
yes
id
b2d770bf-6b2a-497f-8a18-16b57cc30f27
date added to LUP
2026-01-14 12:21:49
date last changed
2026-01-14 12:22:08
@article{b2d770bf-6b2a-497f-8a18-16b57cc30f27,
  abstract     = {{<p>Background: Detecting and monitoring monoclonal free light immunoglobulin chains in serum is important for managing patients with B-cell neoplasms. Established methods have relied on immunochemistry, with monoclonality determined through an abnormal ratio of free kappa and lambda chains and an increased concentration of the involved chain. This indirect approach has limitations. Mass spectrometric methods that directly demonstrate the monoclonal fraction have been described; however, all reported approaches so far are affinity-dependent. The aim of this study was to develop a non–affinity-dependent high-resolution mass spectrometry (HRMS) method. Methods: Samples were prepared using ultrafiltration, then separated by reversed-phase liquid chromatography and analyzed by HRMS. The performance of the method was evaluated, including a comparison with a nephelometric immunoassay for free light immunoglobulin chains. Results: Concordance between HRMS and the immunoassay in classifying a sample as containing a monoclonal free light chain or not was 84% (based on 100 unique patient samples). HRMS identified more samples containing a monoclonal free light chain than the immunoassay. Some monoclonal fractions were glycosylated and/or cysteinylated. Imprecision (CV) for the concentration measurements of monoclonal fractions ranged from 10 to 14%. Conclusions: The HRMS method presented can detect, isotype, and semi-quantify monoclonal monomeric and dimeric light chains in serum, as well as demonstrate post-translational modifications. It is a selective, non–affinity-dependent method with a simple workflow that has the potential to become a valuable tool in the management of B-cell diseases.</p>}},
  author       = {{Bengtson, Per and Förnvik Jonsson, Magnus}},
  issn         = {{2667-1468}},
  keywords     = {{DDA; Deconvolution; FLC; FLC-immunoassay; LC-HRMS; Mass spectrometry; Monoclonal immunoglobulin; MS; Ultrafiltration}},
  language     = {{eng}},
  pages        = {{88--96}},
  series       = {{Journal of Mass Spectrometry and Advances in the Clinical Lab}},
  title        = {{A non-affinity-dependent high-resolution mass spectrometry method for detecting and typing monoclonal free light immunoglobulin chains}},
  url          = {{http://dx.doi.org/10.1016/j.jmsacl.2025.11.004}},
  doi          = {{10.1016/j.jmsacl.2025.11.004}},
  volume       = {{38}},
  year         = {{2025}},
}