Adjustable ECR Ion Source Control System: Ion Source Hydrogen Positive Project
(2015) In IEEE Transactions on Nuclear Science 62(3). p.903-910- Abstract
- ISHP (Ion Source Hydrogen Positive) project consists of a highly versatile ECR type ion source. It has been built for several purposes, on the one hand, to serve as a workbench to test accelerator related technologies and validate in-house made developments, at the first stages. On the other hand, to design an ion source valid as the first step in an actual LINAC. Since this paper is focused on the control system of ISHP, besides the ion source, all the hardware and its control architecture is presented. Nowadays the ion source is able to generate a pulse of positive ions of Hydrogen from 2 mu s to a few range with a repetition rate ranging from 1 Hz to 50 Hz with a maximum of 45 mA of current. Furthermore, the first experiments with White... (More)
- ISHP (Ion Source Hydrogen Positive) project consists of a highly versatile ECR type ion source. It has been built for several purposes, on the one hand, to serve as a workbench to test accelerator related technologies and validate in-house made developments, at the first stages. On the other hand, to design an ion source valid as the first step in an actual LINAC. Since this paper is focused on the control system of ISHP, besides the ion source, all the hardware and its control architecture is presented. Nowadays the ion source is able to generate a pulse of positive ions of Hydrogen from 2 mu s to a few range with a repetition rate ranging from 1 Hz to 50 Hz with a maximum of 45 mA of current. Furthermore, the first experiments with White Rabbit (WR) synchronization system are presented. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/7601753
- author
- organization
- publishing date
- 2015
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- Decentralized control, ion sources
- in
- IEEE Transactions on Nuclear Science
- volume
- 62
- issue
- 3
- pages
- 903 - 910
- publisher
- IEEE - Institute of Electrical and Electronics Engineers Inc.
- external identifiers
-
- wos:000356458000006
- scopus:85028216274
- ISSN
- 0018-9499
- DOI
- 10.1109/TNS.2015.2432036
- language
- English
- LU publication?
- yes
- id
- b5d2fee2-fa9f-4419-95b7-4a6eaf7934d9 (old id 7601753)
- date added to LUP
- 2016-04-01 13:45:50
- date last changed
- 2022-01-27 20:59:25
@article{b5d2fee2-fa9f-4419-95b7-4a6eaf7934d9, abstract = {{ISHP (Ion Source Hydrogen Positive) project consists of a highly versatile ECR type ion source. It has been built for several purposes, on the one hand, to serve as a workbench to test accelerator related technologies and validate in-house made developments, at the first stages. On the other hand, to design an ion source valid as the first step in an actual LINAC. Since this paper is focused on the control system of ISHP, besides the ion source, all the hardware and its control architecture is presented. Nowadays the ion source is able to generate a pulse of positive ions of Hydrogen from 2 mu s to a few range with a repetition rate ranging from 1 Hz to 50 Hz with a maximum of 45 mA of current. Furthermore, the first experiments with White Rabbit (WR) synchronization system are presented.}}, author = {{Arredondo, I. and Eguiraun, M. and Jugo, J. and Piso Fernandez, Daniel and del Campo, M. and Poggi, T. and Varnasseri, S. and Feuchtwanger, J. and Bilbao, J. and Gonzalez, X. and Harper, G. and Muguira, L. and Miracoli, R. and Corres, J. and Belver, D. and Echevarria, P. and Garmendia, N. and Gonzalez, P. and Etxebarria, V.}}, issn = {{0018-9499}}, keywords = {{Decentralized control; ion sources}}, language = {{eng}}, number = {{3}}, pages = {{903--910}}, publisher = {{IEEE - Institute of Electrical and Electronics Engineers Inc.}}, series = {{IEEE Transactions on Nuclear Science}}, title = {{Adjustable ECR Ion Source Control System: Ion Source Hydrogen Positive Project}}, url = {{http://dx.doi.org/10.1109/TNS.2015.2432036}}, doi = {{10.1109/TNS.2015.2432036}}, volume = {{62}}, year = {{2015}}, }