Effect of interfering substances on current response of recombinant peroxidase and glucose oxidase-recombinant peroxidase modified graphite electrodes

Dock, Eva LU ; Lindgren, A ; Ruzgas, Tautgirdas LU and Gorton, Lo LU (2001) In Analyst 126(11). p.35-1929
Abstract
Graphite electrodes have been modified with different forms of horseradish peroxidase (HRP). These included native HRP, wild-type recombinant HRP, and two single-point recombinant HRP mutants, N70V and N70D. The mediator-less response of these electrodes to H2O2 was studied indicating that electrodes modified with recombinant HRP forms are more stable than those modified with native HRP. Various interfering compounds were investigated for their effect on the current response to H2O2. It was found that interferences such as acetaminophen and dopamine affected the response by mediating the electron transfer (ET) between graphite and peroxidases. The mediating behaviour manifested itself as an increased current of the electrode to H2O2. The... (More)
Graphite electrodes have been modified with different forms of horseradish peroxidase (HRP). These included native HRP, wild-type recombinant HRP, and two single-point recombinant HRP mutants, N70V and N70D. The mediator-less response of these electrodes to H2O2 was studied indicating that electrodes modified with recombinant HRP forms are more stable than those modified with native HRP. Various interfering compounds were investigated for their effect on the current response to H2O2. It was found that interferences such as acetaminophen and dopamine affected the response by mediating the electron transfer (ET) between graphite and peroxidases. The mediating behaviour manifested itself as an increased current of the electrode to H2O2. The interfering effect was less pronounced for the electrodes modified with recombinant HRPs possessing better electronic coupling with the graphite surface. The interfering behaviour of acetaminophen on the response for glucose with the bienzyme electrode containing co-immobilised glucose oxidase and HRP was mainly ascribed to mediation of ET between graphite and HRP. It was experimentally proven that a high efficiency of direct ET between graphite and recombinant HRP substantially reduces the interfering effect of acetaminophen. (Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Analyst
volume
126
issue
11
pages
35 - 1929
publisher
Royal Society of Chemistry
external identifiers
  • scopus:0035191024
ISSN
1364-5528
language
English
LU publication?
yes
additional info
The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Analytical Chemistry (S/LTH) (011001004)
id
b7092d1f-33f5-490b-84e5-95add388a48c (old id 107096)
alternative location
http://www.ncbi.nlm.nih.gov:80/entrez/query.fcgi?cmd=Retrieve&db=PubMed&list_uids=11763069&dopt=Abstract
date added to LUP
2016-04-01 16:56:39
date last changed
2022-01-28 23:12:08
@article{b7092d1f-33f5-490b-84e5-95add388a48c,
  abstract     = {{Graphite electrodes have been modified with different forms of horseradish peroxidase (HRP). These included native HRP, wild-type recombinant HRP, and two single-point recombinant HRP mutants, N70V and N70D. The mediator-less response of these electrodes to H2O2 was studied indicating that electrodes modified with recombinant HRP forms are more stable than those modified with native HRP. Various interfering compounds were investigated for their effect on the current response to H2O2. It was found that interferences such as acetaminophen and dopamine affected the response by mediating the electron transfer (ET) between graphite and peroxidases. The mediating behaviour manifested itself as an increased current of the electrode to H2O2. The interfering effect was less pronounced for the electrodes modified with recombinant HRPs possessing better electronic coupling with the graphite surface. The interfering behaviour of acetaminophen on the response for glucose with the bienzyme electrode containing co-immobilised glucose oxidase and HRP was mainly ascribed to mediation of ET between graphite and HRP. It was experimentally proven that a high efficiency of direct ET between graphite and recombinant HRP substantially reduces the interfering effect of acetaminophen.}},
  author       = {{Dock, Eva and Lindgren, A and Ruzgas, Tautgirdas and Gorton, Lo}},
  issn         = {{1364-5528}},
  language     = {{eng}},
  number       = {{11}},
  pages        = {{35--1929}},
  publisher    = {{Royal Society of Chemistry}},
  series       = {{Analyst}},
  title        = {{Effect of interfering substances on current response of recombinant peroxidase and glucose oxidase-recombinant peroxidase modified graphite electrodes}},
  url          = {{http://www.ncbi.nlm.nih.gov:80/entrez/query.fcgi?cmd=Retrieve&db=PubMed&list_uids=11763069&dopt=Abstract}},
  volume       = {{126}},
  year         = {{2001}},
}