Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Mechanics of a mosquito bite with applications to microneedle design

Ramasubramanian, M K ; Barham, O M and Swaminathan, V LU (2008) In Bioinspiration & Biomimetics 3(4). p.046001-046001
Abstract

The mechanics of a fascicle insertion into the skin by a mosquito of the type aedes aegypti has been studied experimentally using high-speed video (HSV) imaging, and analytically using a mathematical model. The fascicle is a polymeric microneedle composed of a ductile material, chitin. It has been proposed that the mosquito applies a non-conservative follower force component in addition to the Euler compressive load in order to prevent buckling and penetrate the skin. In addition, the protective sheath surrounding the fascicle (labium) provides lateral support during insertion. The mechanics model presented approximates the fascicle as a slender column supported on an elastic foundation (labium) subjected to non-conservative (Beck) and... (More)

The mechanics of a fascicle insertion into the skin by a mosquito of the type aedes aegypti has been studied experimentally using high-speed video (HSV) imaging, and analytically using a mathematical model. The fascicle is a polymeric microneedle composed of a ductile material, chitin. It has been proposed that the mosquito applies a non-conservative follower force component in addition to the Euler compressive load in order to prevent buckling and penetrate the skin. In addition, the protective sheath surrounding the fascicle (labium) provides lateral support during insertion. The mechanics model presented approximates the fascicle as a slender column supported on an elastic foundation (labium) subjected to non-conservative (Beck) and conservative Euler loads simultaneously at the end. Results show that the lateral support of the fascicle provided by the labium is essential for successful penetration by increasing the critical buckling load by a factor of 5. The non-conservative follower force application increases the buckling load by an additional 20% and may or may not be necessary for successful penetration. Experimental results showing the importance of the labium have been cited to validate the model predictions, in addition to the video observations presented in this work. This understanding may be useful in designing painless needle insertion systems as opposed to miniaturized hypodermic needles.

(Less)
Please use this url to cite or link to this publication:
author
; and
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Animals, Biomimetics/instrumentation, Computer Simulation, Computer-Aided Design, Culicidae/physiology, Equipment Design, Equipment Failure Analysis, Humans, Insect Bites and Stings/physiopathology, Microinjections/instrumentation, Models, Biological, Needles, Skin/injuries, Wounds, Penetrating/physiopathology
in
Bioinspiration & Biomimetics
volume
3
issue
4
pages
046001 - 046001
publisher
IOP Publishing
external identifiers
  • pmid:18779629
  • scopus:58149482569
ISSN
1748-3190
DOI
10.1088/1748-3182/3/4/046001
language
English
LU publication?
no
id
b7d2a456-21b1-4707-8fef-18e3b8dd388f
date added to LUP
2018-08-20 16:49:38
date last changed
2024-06-10 16:11:21
@article{b7d2a456-21b1-4707-8fef-18e3b8dd388f,
  abstract     = {{<p>The mechanics of a fascicle insertion into the skin by a mosquito of the type aedes aegypti has been studied experimentally using high-speed video (HSV) imaging, and analytically using a mathematical model. The fascicle is a polymeric microneedle composed of a ductile material, chitin. It has been proposed that the mosquito applies a non-conservative follower force component in addition to the Euler compressive load in order to prevent buckling and penetrate the skin. In addition, the protective sheath surrounding the fascicle (labium) provides lateral support during insertion. The mechanics model presented approximates the fascicle as a slender column supported on an elastic foundation (labium) subjected to non-conservative (Beck) and conservative Euler loads simultaneously at the end. Results show that the lateral support of the fascicle provided by the labium is essential for successful penetration by increasing the critical buckling load by a factor of 5. The non-conservative follower force application increases the buckling load by an additional 20% and may or may not be necessary for successful penetration. Experimental results showing the importance of the labium have been cited to validate the model predictions, in addition to the video observations presented in this work. This understanding may be useful in designing painless needle insertion systems as opposed to miniaturized hypodermic needles.</p>}},
  author       = {{Ramasubramanian, M K and Barham, O M and Swaminathan, V}},
  issn         = {{1748-3190}},
  keywords     = {{Animals; Biomimetics/instrumentation; Computer Simulation; Computer-Aided Design; Culicidae/physiology; Equipment Design; Equipment Failure Analysis; Humans; Insect Bites and Stings/physiopathology; Microinjections/instrumentation; Models, Biological; Needles; Skin/injuries; Wounds, Penetrating/physiopathology}},
  language     = {{eng}},
  number       = {{4}},
  pages        = {{046001--046001}},
  publisher    = {{IOP Publishing}},
  series       = {{Bioinspiration & Biomimetics}},
  title        = {{Mechanics of a mosquito bite with applications to microneedle design}},
  url          = {{http://dx.doi.org/10.1088/1748-3182/3/4/046001}},
  doi          = {{10.1088/1748-3182/3/4/046001}},
  volume       = {{3}},
  year         = {{2008}},
}