Uncompensated blood loss is not tolerated during acute normovolemic hemodilution in anesthetized pigs
(1998) In Anesthesia and Analgesia 87(4). p.786-794- Abstract
- Clinically, hemodilution to a hematocrit of 9% has been studied, but the effects of hypovolemia during this degree of hemodilution have not been elucidated. We studied the response to blood loss during extreme hemodilution and evaluated indicators of hypovolemia. Systemic and myocardial hemodynamics, oxygen transport, and blood lactate concentrations were measured in 12 anesthetized pigs exposed to a graded blood loss of 10, 20, 30, and 40 mL/kg. Six animals were hemodiluted (hematocrit 10.8% +/- 1.4%, mean +/- SD), and six animals served as controls (hematocrit 34.6% +/- 1.5%). Hemodilution decreased systemic oxygen delivery to 9.5 +/- 0.6 mL x kg(-1) x min(-1) (controls 21.7 +/- 3.9 mL x kg(-1) x min(-1)) (P < 0.01) despite a 31%... (More)
- Clinically, hemodilution to a hematocrit of 9% has been studied, but the effects of hypovolemia during this degree of hemodilution have not been elucidated. We studied the response to blood loss during extreme hemodilution and evaluated indicators of hypovolemia. Systemic and myocardial hemodynamics, oxygen transport, and blood lactate concentrations were measured in 12 anesthetized pigs exposed to a graded blood loss of 10, 20, 30, and 40 mL/kg. Six animals were hemodiluted (hematocrit 10.8% +/- 1.4%, mean +/- SD), and six animals served as controls (hematocrit 34.6% +/- 1.5%). Hemodilution decreased systemic oxygen delivery to 9.5 +/- 0.6 mL x kg(-1) x min(-1) (controls 21.7 +/- 3.9 mL x kg(-1) x min(-1)) (P < 0.01) despite a 31% increase in cardiac output. Systemic oxygen uptake was unchanged. Arterial lactate increased to 3.3 +/- 1.1 mM/L (controls 1.6 +/- 0.6 mM/L) (P < 0.05), and mixed venous oxygen saturation (SvO2) decreased to 38.2% + 4.8% (controls 68.6% +/- 2.9%) (P < 0.01). At a blood loss of 10 mL/kg, cardiac output continued to be greater in the hemodiluted animals (P < 0.01). Arterial blood pressure decreased to 61 +/- 8 mmHg (controls 84 +/- 18 mm Hg) (P < 0.05), whereas heart rate was unchanged. Systemic oxygen delivery decreased to 8.8 +/- 1.2 mL x kg(-1) x min(-1) (controls 14.1 +/- 2.5 mL x kg(-1) x min(-1)) (P < 0.01). Systemic oxygen uptake was maintained by a further increase in oxygen extraction, and SvO2 decreased to 29.7% +/- 7.3%, compared with 55.3% +/- 9.0% in controls (P < 0.01). Arterial lactate increased to 4.9 +/- 1.4 mM/L (controls 1.8 +/- 0.8 mM/L) (P < 0.01). Myocardial oxygen delivery and lactate uptake were unchanged. When the blood loss equaled 30 mL/kg, myocardial lactate production occurred, and two hemodiluted animals died of circulatory failure. Central venous and capillary wedge pressures changed minimally during the blood loss and did not differ between groups. We conclude that a decrease in arterial blood pressure and SvO2 were early signs of hypovolemia during hemodilution, whereas central venous pressure and pulmonary capillary wedge pressure were insensitive indicators. IMPLICATIONS: Anesthetized pigs with extremely low hemoglobin levels (one third of normal) showed poor tolerance to blood loss >10 mL/kg. A decreasing arterial blood pressure, a decreasing oxygen saturation in the venous blood, and an increase in arterial blood lactate concentration were useful indicators of blood loss. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1113388
- author
- Schou, Henning LU ; Kongstad, Lis LU ; Perez de Sá, Valéria LU ; Werner, Olof LU and Larsson, Anders
- organization
- publishing date
- 1998
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Anesthesia and Analgesia
- volume
- 87
- issue
- 4
- pages
- 786 - 794
- publisher
- Lippincott Williams & Wilkins
- external identifiers
-
- pmid:9768771
- scopus:0031661380
- ISSN
- 1526-7598
- language
- English
- LU publication?
- yes
- id
- ba651caf-d2f4-4c8a-8a9f-654354eebf04 (old id 1113388)
- alternative location
- http://www.anesthesia-analgesia.org/cgi/reprint/87/4/786
- date added to LUP
- 2016-04-01 15:21:42
- date last changed
- 2022-01-28 04:59:39
@article{ba651caf-d2f4-4c8a-8a9f-654354eebf04, abstract = {{Clinically, hemodilution to a hematocrit of 9% has been studied, but the effects of hypovolemia during this degree of hemodilution have not been elucidated. We studied the response to blood loss during extreme hemodilution and evaluated indicators of hypovolemia. Systemic and myocardial hemodynamics, oxygen transport, and blood lactate concentrations were measured in 12 anesthetized pigs exposed to a graded blood loss of 10, 20, 30, and 40 mL/kg. Six animals were hemodiluted (hematocrit 10.8% +/- 1.4%, mean +/- SD), and six animals served as controls (hematocrit 34.6% +/- 1.5%). Hemodilution decreased systemic oxygen delivery to 9.5 +/- 0.6 mL x kg(-1) x min(-1) (controls 21.7 +/- 3.9 mL x kg(-1) x min(-1)) (P < 0.01) despite a 31% increase in cardiac output. Systemic oxygen uptake was unchanged. Arterial lactate increased to 3.3 +/- 1.1 mM/L (controls 1.6 +/- 0.6 mM/L) (P < 0.05), and mixed venous oxygen saturation (SvO2) decreased to 38.2% + 4.8% (controls 68.6% +/- 2.9%) (P < 0.01). At a blood loss of 10 mL/kg, cardiac output continued to be greater in the hemodiluted animals (P < 0.01). Arterial blood pressure decreased to 61 +/- 8 mmHg (controls 84 +/- 18 mm Hg) (P < 0.05), whereas heart rate was unchanged. Systemic oxygen delivery decreased to 8.8 +/- 1.2 mL x kg(-1) x min(-1) (controls 14.1 +/- 2.5 mL x kg(-1) x min(-1)) (P < 0.01). Systemic oxygen uptake was maintained by a further increase in oxygen extraction, and SvO2 decreased to 29.7% +/- 7.3%, compared with 55.3% +/- 9.0% in controls (P < 0.01). Arterial lactate increased to 4.9 +/- 1.4 mM/L (controls 1.8 +/- 0.8 mM/L) (P < 0.01). Myocardial oxygen delivery and lactate uptake were unchanged. When the blood loss equaled 30 mL/kg, myocardial lactate production occurred, and two hemodiluted animals died of circulatory failure. Central venous and capillary wedge pressures changed minimally during the blood loss and did not differ between groups. We conclude that a decrease in arterial blood pressure and SvO2 were early signs of hypovolemia during hemodilution, whereas central venous pressure and pulmonary capillary wedge pressure were insensitive indicators. IMPLICATIONS: Anesthetized pigs with extremely low hemoglobin levels (one third of normal) showed poor tolerance to blood loss >10 mL/kg. A decreasing arterial blood pressure, a decreasing oxygen saturation in the venous blood, and an increase in arterial blood lactate concentration were useful indicators of blood loss.}}, author = {{Schou, Henning and Kongstad, Lis and Perez de Sá, Valéria and Werner, Olof and Larsson, Anders}}, issn = {{1526-7598}}, language = {{eng}}, number = {{4}}, pages = {{786--794}}, publisher = {{Lippincott Williams & Wilkins}}, series = {{Anesthesia and Analgesia}}, title = {{Uncompensated blood loss is not tolerated during acute normovolemic hemodilution in anesthetized pigs}}, url = {{http://www.anesthesia-analgesia.org/cgi/reprint/87/4/786}}, volume = {{87}}, year = {{1998}}, }