Results from the first preclinical CT scanner with grating based phase contrast and a rotating gantry
(2012) International Workshop on X-Ray and Neutron Phase Imaging with Gratings, XNPIG 2012 In AIP Conference Proceedings 1466. p.130-136- Abstract
After successful demonstrations of soft-tissue phase-contrast imaging with grating interferometers at synchrotron radiation sources and at laboratory based x-ray tubes, a first preclinical CT scanner with grating based phase contrast imaging modality has been constructed. The rotating gantry is equipped with a three-grating interferometer, a 50 watt tungsten anode source and a Hamamatsu flat panel detector. The total length of the interferometer is 45 cm, and the bed of the scanner is optimized for mice, with a scanning diameter of 35 mm. From one single scan both phase-contrast and standard attenuation based tomography can be attained, providing an overall gain in image contrast.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/bce55ca7-2c6b-4476-ba2d-a6991604ff21
- author
- organization
- publishing date
- 2012
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- Preclinical, Tomography, X-ray Phase-contrast
- host publication
- International Workshop on X-Ray and Neutron Phase Imaging with Gratings
- series title
- AIP Conference Proceedings
- editor
- Momose, Atsushi and Yashiro, Wataru
- volume
- 1466
- pages
- 7 pages
- publisher
- American Institute of Physics (AIP)
- conference name
- International Workshop on X-Ray and Neutron Phase Imaging with Gratings, XNPIG 2012
- conference location
- Tokyo, Japan
- conference dates
- 2012-03-05 - 2012-03-07
- external identifiers
-
- scopus:84873257872
- ISSN
- 1551-7616
- 0094-243X
- ISBN
- 9780735410725
- DOI
- 10.1063/1.4742281
- language
- English
- LU publication?
- yes
- id
- bce55ca7-2c6b-4476-ba2d-a6991604ff21
- date added to LUP
- 2022-04-07 11:17:53
- date last changed
- 2025-04-04 15:00:01
@inproceedings{bce55ca7-2c6b-4476-ba2d-a6991604ff21, abstract = {{<p>After successful demonstrations of soft-tissue phase-contrast imaging with grating interferometers at synchrotron radiation sources and at laboratory based x-ray tubes, a first preclinical CT scanner with grating based phase contrast imaging modality has been constructed. The rotating gantry is equipped with a three-grating interferometer, a 50 watt tungsten anode source and a Hamamatsu flat panel detector. The total length of the interferometer is 45 cm, and the bed of the scanner is optimized for mice, with a scanning diameter of 35 mm. From one single scan both phase-contrast and standard attenuation based tomography can be attained, providing an overall gain in image contrast.</p>}}, author = {{Bech, Martin and Tapfer, Arne and Velroyen, Astrid and Yaroshenko, Andre and Pauwels, Bart and Bruyndonckx, Peter and Liu, Xuan and Sasov, Alexander and Mohr, Jürgen and Walter, Marco and Pfeiffer, Franz}}, booktitle = {{International Workshop on X-Ray and Neutron Phase Imaging with Gratings}}, editor = {{Momose, Atsushi and Yashiro, Wataru}}, isbn = {{9780735410725}}, issn = {{1551-7616}}, keywords = {{Preclinical; Tomography; X-ray Phase-contrast}}, language = {{eng}}, pages = {{130--136}}, publisher = {{American Institute of Physics (AIP)}}, series = {{AIP Conference Proceedings}}, title = {{Results from the first preclinical CT scanner with grating based phase contrast and a rotating gantry}}, url = {{http://dx.doi.org/10.1063/1.4742281}}, doi = {{10.1063/1.4742281}}, volume = {{1466}}, year = {{2012}}, }