Assesment of patient doses and possible approaches for implementation of optimization procedures in PET/CT examinations in the Russian Federation
(2017) In Medical Physics in the Baltic States p.36-40- Abstract
- A dose survey of positron emission tomography (PET) examinations was performed in 12 regions of the Russian Federation, where the effective dose values were assessed for the various types of PET examinations. The comparison to similar published data show that the patient doses in Russia are higher than in other countries. Low-dose CT protocols and justification of multiphase CT protocols should be considered for future optimization and radiation protection of patients.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/bdd2fdc6-2908-4d2b-ad49-c03cb4d36b06
- author
- Chipiga, Larisa ; Vodovatov, Aleksandr LU ; Zvonova, Irina and Bernhardsson, Christian LU
- organization
- publishing date
- 2017
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- positron emission tomography (PET), Computed tomography (CT), Nuclear Medicine
- host publication
- Medical Physics in the Baltic States : Proceedings of the 13th International Conference on Medical Physics - Proceedings of the 13th International Conference on Medical Physics
- series title
- Medical Physics in the Baltic States
- editor
- Adliene, Diana
- pages
- 4 pages
- publisher
- Kaunas University Of Technology Press
- ISSN
- 1822-5721
- project
- Radiation protection in Eastern Europe
- language
- English
- LU publication?
- yes
- id
- bdd2fdc6-2908-4d2b-ad49-c03cb4d36b06
- date added to LUP
- 2018-01-04 14:26:34
- date last changed
- 2018-11-21 21:37:04
@inproceedings{bdd2fdc6-2908-4d2b-ad49-c03cb4d36b06, abstract = {{A dose survey of positron emission tomography (PET) examinations was performed in 12 regions of the Russian Federation, where the effective dose values were assessed for the various types of PET examinations. The comparison to similar published data show that the patient doses in Russia are higher than in other countries. Low-dose CT protocols and justification of multiphase CT protocols should be considered for future optimization and radiation protection of patients.}}, author = {{Chipiga, Larisa and Vodovatov, Aleksandr and Zvonova, Irina and Bernhardsson, Christian}}, booktitle = {{Medical Physics in the Baltic States : Proceedings of the 13th International Conference on Medical Physics}}, editor = {{Adliene, Diana}}, issn = {{1822-5721}}, keywords = {{positron emission tomography (PET); Computed tomography (CT); Nuclear Medicine}}, language = {{eng}}, pages = {{36--40}}, publisher = {{Kaunas University Of Technology Press}}, series = {{Medical Physics in the Baltic States}}, title = {{Assesment of patient doses and possible approaches for implementation of optimization procedures in PET/CT examinations in the Russian Federation}}, url = {{https://lup.lub.lu.se/search/files/36215718/Chipiga_et_al_2017_Assessment_of_patient_doses_and_possible_approaches_for_implementation_of_optimization_procedures_in_PET_CT.pdf}}, year = {{2017}}, }