Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

New data for sandwich panels on the correlation between the SBI test method and the room corner reference scenario

Axelsson, Jesper and Van Hees, Patrick LU (2005) In Fire and Materials 29(1). p.53-59
Abstract
Assessment of the fire behaviour of sandwich panels is continuously under discussion. The fire behaviour of these panels is a combination of material characteristics such as the core material and mechanical behaviour of the panels such as joints, dilations etc. The use of small or intermediate scale tests can be questioned for such types of products.





Within the proposed European product standard for sandwich panels (prEN 14509) the intermediate scale test method SBI (EN 13823) has been suggested as the fire test method to certify panels. The standard does, however, use quite an artificial mounting procedure, which does not fully reflect the end-use conditions of the panels.





In a... (More)
Assessment of the fire behaviour of sandwich panels is continuously under discussion. The fire behaviour of these panels is a combination of material characteristics such as the core material and mechanical behaviour of the panels such as joints, dilations etc. The use of small or intermediate scale tests can be questioned for such types of products.





Within the proposed European product standard for sandwich panels (prEN 14509) the intermediate scale test method SBI (EN 13823) has been suggested as the fire test method to certify panels. The standard does, however, use quite an artificial mounting procedure, which does not fully reflect the end-use conditions of the panels.





In a previous research project conducted by Nordtest it was shown that the correlation between the SBI test method and both the ISO 9705 and ISO 13784 part 1 was insufficient. The test data produced for the SBI test method, however, did not use the above mentioned mounting technique.





In this article new data for a number of products are added to the database using the mounting procedure of the product standard. The data are compared with the previous data and show that the mounting method of the product standard results in slightly more severe conditions but that there are still discrepancies with the full-scale test results. The data also show an unacceptable level of repeatability due to the fact that small dilations result in a wide variation of classification result. The new data together with the old data show once more that it is dangerous to make a fire safety assessment of a sandwich panel based on small or intermediate scale tests. (Less)
Please use this url to cite or link to this publication:
author
and
publishing date
type
Contribution to journal
publication status
published
subject
in
Fire and Materials
volume
29
issue
1
pages
53 - 59
publisher
John Wiley & Sons Inc.
external identifiers
  • scopus:13444273261
ISSN
1099-1018
DOI
10.1002/fam.879
language
English
LU publication?
no
id
c0c8e7c3-26df-4a0e-92e1-55e3de494216 (old id 4434594)
date added to LUP
2016-04-01 16:11:06
date last changed
2022-01-28 17:55:28
@article{c0c8e7c3-26df-4a0e-92e1-55e3de494216,
  abstract     = {{Assessment of the fire behaviour of sandwich panels is continuously under discussion. The fire behaviour of these panels is a combination of material characteristics such as the core material and mechanical behaviour of the panels such as joints, dilations etc. The use of small or intermediate scale tests can be questioned for such types of products.<br/><br>
<br/><br>
<br/><br>
Within the proposed European product standard for sandwich panels (prEN 14509) the intermediate scale test method SBI (EN 13823) has been suggested as the fire test method to certify panels. The standard does, however, use quite an artificial mounting procedure, which does not fully reflect the end-use conditions of the panels.<br/><br>
<br/><br>
<br/><br>
In a previous research project conducted by Nordtest it was shown that the correlation between the SBI test method and both the ISO 9705 and ISO 13784 part 1 was insufficient. The test data produced for the SBI test method, however, did not use the above mentioned mounting technique.<br/><br>
<br/><br>
<br/><br>
In this article new data for a number of products are added to the database using the mounting procedure of the product standard. The data are compared with the previous data and show that the mounting method of the product standard results in slightly more severe conditions but that there are still discrepancies with the full-scale test results. The data also show an unacceptable level of repeatability due to the fact that small dilations result in a wide variation of classification result. The new data together with the old data show once more that it is dangerous to make a fire safety assessment of a sandwich panel based on small or intermediate scale tests.}},
  author       = {{Axelsson, Jesper and Van Hees, Patrick}},
  issn         = {{1099-1018}},
  language     = {{eng}},
  number       = {{1}},
  pages        = {{53--59}},
  publisher    = {{John Wiley & Sons Inc.}},
  series       = {{Fire and Materials}},
  title        = {{New data for sandwich panels on the correlation between the SBI test method and the room corner reference scenario}},
  url          = {{http://dx.doi.org/10.1002/fam.879}},
  doi          = {{10.1002/fam.879}},
  volume       = {{29}},
  year         = {{2005}},
}