Analysis of PAH compounds in soil with on-line coupled pressurised hot water extraction-microporous membrane liquid-liquid extraction-gas chromatography
(2003) In Analytical and Bioanalytical Chemistry 375(3). p.389-399- Abstract
- Pressurised hot water extraction (PHWE) was coupled on-line with microporous membrane liquid-liquid extraction (MMLLE) and gas chromatography (GC) in the analysis of polycyclic aromatic hydrocarbon (PAH) compounds in soil. The MMLLE serves as a trapping device after the PHWE. Water from PHWE is directed to the donor side of the membrane unit and the analytes are extracted to the acceptor solution on the other side of the membrane. The role of MMLLE is to clean and concentrate the extract, which is then transferred on-line to the GC via a sample loop and an on-column interface using partially concurrent solvent evaporation. Separate optimisation of MMLLE and simulations of the PHWE-MMLLE connection were carried out before the actual on-line... (More)
- Pressurised hot water extraction (PHWE) was coupled on-line with microporous membrane liquid-liquid extraction (MMLLE) and gas chromatography (GC) in the analysis of polycyclic aromatic hydrocarbon (PAH) compounds in soil. The MMLLE serves as a trapping device after the PHWE. Water from PHWE is directed to the donor side of the membrane unit and the analytes are extracted to the acceptor solution on the other side of the membrane. The role of MMLLE is to clean and concentrate the extract, which is then transferred on-line to the GC via a sample loop and an on-column interface using partially concurrent solvent evaporation. Separate optimisation of MMLLE and simulations of the PHWE-MMLLE connection were carried out before the actual on-line coupling. After optimisation of the whole on-line system, the efficiencies of the PHWE-MMLLE-GC and PHWE-solid-phase trap extractions were compared. The PHWE-MMLLE-GC method allowed on-line analysis of soil samples. The method was linear, with limits of detection in the range 0.05-0.13 ng and limits of quantification 0.65-1.66 wg gm1. Comparison of the results with those obtained by other techniques confirmed the good performance. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/128929
- author
- Kuosmanen, K ; Hyötyläinen, T ; Hartonen, K. ; Jönsson, Jan Åke LU and Riekkola, M-L
- organization
- publishing date
- 2003
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Analytical and Bioanalytical Chemistry
- volume
- 375
- issue
- 3
- pages
- 389 - 399
- publisher
- Springer
- external identifiers
-
- wos:000181389900010
- pmid:12589504
- scopus:0038386028
- ISSN
- 1618-2642
- DOI
- 10.1007/s00216-002-1685-0
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Analytical Chemistry (S/LTH) (011001004)
- id
- c349bacb-b2ec-4df0-adeb-4e71aad82a99 (old id 128929)
- date added to LUP
- 2016-04-01 11:36:15
- date last changed
- 2022-01-26 07:31:51
@article{c349bacb-b2ec-4df0-adeb-4e71aad82a99, abstract = {{Pressurised hot water extraction (PHWE) was coupled on-line with microporous membrane liquid-liquid extraction (MMLLE) and gas chromatography (GC) in the analysis of polycyclic aromatic hydrocarbon (PAH) compounds in soil. The MMLLE serves as a trapping device after the PHWE. Water from PHWE is directed to the donor side of the membrane unit and the analytes are extracted to the acceptor solution on the other side of the membrane. The role of MMLLE is to clean and concentrate the extract, which is then transferred on-line to the GC via a sample loop and an on-column interface using partially concurrent solvent evaporation. Separate optimisation of MMLLE and simulations of the PHWE-MMLLE connection were carried out before the actual on-line coupling. After optimisation of the whole on-line system, the efficiencies of the PHWE-MMLLE-GC and PHWE-solid-phase trap extractions were compared. The PHWE-MMLLE-GC method allowed on-line analysis of soil samples. The method was linear, with limits of detection in the range 0.05-0.13 ng and limits of quantification 0.65-1.66 wg gm1. Comparison of the results with those obtained by other techniques confirmed the good performance.}}, author = {{Kuosmanen, K and Hyötyläinen, T and Hartonen, K. and Jönsson, Jan Åke and Riekkola, M-L}}, issn = {{1618-2642}}, language = {{eng}}, number = {{3}}, pages = {{389--399}}, publisher = {{Springer}}, series = {{Analytical and Bioanalytical Chemistry}}, title = {{Analysis of PAH compounds in soil with on-line coupled pressurised hot water extraction-microporous membrane liquid-liquid extraction-gas chromatography}}, url = {{http://dx.doi.org/10.1007/s00216-002-1685-0}}, doi = {{10.1007/s00216-002-1685-0}}, volume = {{375}}, year = {{2003}}, }