Data quality quantification for time domain IP data acquired at a former waste deposit in Lund
(2012) 18th European Meeting of Environmental and Engineering Geophysics of the Near Surface Geoscience Division of EAGE, Near Surface Geoscience 2012- Abstract
Tests were done measuring resistivity and time domain induced polarisation using standard multi-core cable spreads and a special layout with separate cable spreads for transmitting current and measuring potentials. For both types of cables spreads both normal and reciprocal measurements were done in order to estimate the measurement errors. The tests were done on a former landfill in Lund in Sweden. The electrode contact was favourable with resistances of some hundred ohm. The results gave low average error levels for both types of cable spreads, but the single cable spread showed a larger variation with more scatter in the IP data. Data for both types of spreads gave very consistent models that delineate the lateral distribution of... (More)
Tests were done measuring resistivity and time domain induced polarisation using standard multi-core cable spreads and a special layout with separate cable spreads for transmitting current and measuring potentials. For both types of cables spreads both normal and reciprocal measurements were done in order to estimate the measurement errors. The tests were done on a former landfill in Lund in Sweden. The electrode contact was favourable with resistances of some hundred ohm. The results gave low average error levels for both types of cable spreads, but the single cable spread showed a larger variation with more scatter in the IP data. Data for both types of spreads gave very consistent models that delineate the lateral distribution of waste as well as the contaminant leachate flow path. The results agree well with observations of contaminant outflow and test pit results. It is concluded that the standard approach with a single cable spread is adequate for a site with favourable characteristics as the one studied here.
(Less)
- author
- Dahlin, T. LU and Sandström, T.
- organization
- publishing date
- 2012-01-01
- type
- Contribution to conference
- publication status
- published
- subject
- conference name
- 18th European Meeting of Environmental and Engineering Geophysics of the Near Surface Geoscience Division of EAGE, Near Surface Geoscience 2012
- conference location
- Paris, France
- conference dates
- 2012-09-03 - 2012-09-05
- external identifiers
-
- scopus:85085778833
- language
- English
- LU publication?
- yes
- id
- c8fbc3b7-353f-4ede-b7d8-c9db3b74f92b
- date added to LUP
- 2018-11-06 10:09:45
- date last changed
- 2022-01-31 06:46:05
@misc{c8fbc3b7-353f-4ede-b7d8-c9db3b74f92b, abstract = {{<p>Tests were done measuring resistivity and time domain induced polarisation using standard multi-core cable spreads and a special layout with separate cable spreads for transmitting current and measuring potentials. For both types of cables spreads both normal and reciprocal measurements were done in order to estimate the measurement errors. The tests were done on a former landfill in Lund in Sweden. The electrode contact was favourable with resistances of some hundred ohm. The results gave low average error levels for both types of cable spreads, but the single cable spread showed a larger variation with more scatter in the IP data. Data for both types of spreads gave very consistent models that delineate the lateral distribution of waste as well as the contaminant leachate flow path. The results agree well with observations of contaminant outflow and test pit results. It is concluded that the standard approach with a single cable spread is adequate for a site with favourable characteristics as the one studied here.</p>}}, author = {{Dahlin, T. and Sandström, T.}}, language = {{eng}}, month = {{01}}, title = {{Data quality quantification for time domain IP data acquired at a former waste deposit in Lund}}, year = {{2012}}, }