- Methods for measuring diffusion coefficients in gels are reviewed, and their capacities, limitations and requirements are briefly discussed. With four of these methods, i.e., the diaphragm cell, uptake/release from beads, holographic laser interferometry and nuclear magnetic resonance (FT-PGSE), a comparison is made with regard to accuracy and precision. The comparison is based on a number of studies in which the diffusion coefficient of ethanol in agarose gel has been measured. It is concluded that the diaphragm cell and nuclear magnetic resonance (FT-PGSE) are very accurate and precise.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/3918179
- author
- Westrin, BA ; Axelsson, Anders LU and Zacchi, Guido LU
- organization
- publishing date
- 1994
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- DIFFUSION, GEL, MEASUREMENT, ACCURACY, PRECISION
- in
- Journal of Controlled Release
- volume
- 30
- issue
- 3
- pages
- 189 - 199
- publisher
- Elsevier
- external identifiers
-
- wos:A1994NY35400001
- scopus:0028338623
- ISSN
- 1873-4995
- DOI
- 10.1016/0168-3659(94)90025-6
- language
- English
- LU publication?
- yes
- id
- cca29866-5eb3-4abd-a70c-233ec8b0e1f3 (old id 3918179)
- date added to LUP
- 2016-04-01 12:02:06
- date last changed
- 2025-10-14 09:15:35
@article{cca29866-5eb3-4abd-a70c-233ec8b0e1f3,
abstract = {{Methods for measuring diffusion coefficients in gels are reviewed, and their capacities, limitations and requirements are briefly discussed. With four of these methods, i.e., the diaphragm cell, uptake/release from beads, holographic laser interferometry and nuclear magnetic resonance (FT-PGSE), a comparison is made with regard to accuracy and precision. The comparison is based on a number of studies in which the diffusion coefficient of ethanol in agarose gel has been measured. It is concluded that the diaphragm cell and nuclear magnetic resonance (FT-PGSE) are very accurate and precise.}},
author = {{Westrin, BA and Axelsson, Anders and Zacchi, Guido}},
issn = {{1873-4995}},
keywords = {{DIFFUSION; GEL; MEASUREMENT; ACCURACY; PRECISION}},
language = {{eng}},
number = {{3}},
pages = {{189--199}},
publisher = {{Elsevier}},
series = {{Journal of Controlled Release}},
title = {{Diffusion measurement in gels}},
url = {{http://dx.doi.org/10.1016/0168-3659(94)90025-6}},
doi = {{10.1016/0168-3659(94)90025-6}},
volume = {{30}},
year = {{1994}},
}