Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Effect of femoral head size on polyethylene wear and synovitis after total hip arthroplasty - A sonographic and radiographic study of 39 patients

Tarasevicius, Sarunas ; Robertsson, Otto LU ; Kesteris, Uldis LU ; Kalesinskas, Romas Jonas and Wingstrand, Hans LU (2008) In Acta Orthopaedica 79(4). p.489-493
Abstract
Background and purpose The role of synovitis and high fluid pressure in the loosening process after total hip arthroplasty has gained increasing attention. We investigated the correlation between head size, polyethylene wear, and capsular distention. Patients and methods We analyzed 39 unrevised, radiographically stable hips that had been operated with 28 or 32 mm femoral heads 10 years earlier because of osteoarthritis. We evaluated radiographic signs of loosening, linear and volumetric polyethylene wear, body mass index, activity level, and age. Sonographic examination was performed to measure capsular distance i.e. the distance between the prosthetic femoral neck and the anterior capsule. Results Linear wear was 0.09 mm/year and 0.18... (More)
Background and purpose The role of synovitis and high fluid pressure in the loosening process after total hip arthroplasty has gained increasing attention. We investigated the correlation between head size, polyethylene wear, and capsular distention. Patients and methods We analyzed 39 unrevised, radiographically stable hips that had been operated with 28 or 32 mm femoral heads 10 years earlier because of osteoarthritis. We evaluated radiographic signs of loosening, linear and volumetric polyethylene wear, body mass index, activity level, and age. Sonographic examination was performed to measure capsular distance i.e. the distance between the prosthetic femoral neck and the anterior capsule. Results Linear wear was 0.09 mm/year and 0.18 mm/year in the 28 mm and 32 mm groups, respectively (p 0.001). The volumetric wear was 51 mm3/year and 136 mm3/year (p < 0.001) and the capsular distance was 13 mm and 17 mm, respectively (p < 0.001). There was a correlation between linear wear (r = 0.54), volumetric wear (r = 0.62), and capsular distance (p < 0.001). Interpretation Wear was greater for the larger femoral head and was correlated to capsular distension. (Less)
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Acta Orthopaedica
volume
79
issue
4
pages
489 - 493
publisher
Taylor & Francis
external identifiers
  • wos:000258922600006
  • scopus:51049108385
  • pmid:18766481
ISSN
1745-3682
DOI
10.1080/17453670710015472
language
English
LU publication?
yes
id
d0569695-db30-4f56-905c-7d2a4ea86b09 (old id 1247343)
date added to LUP
2016-04-01 13:49:47
date last changed
2022-03-14 02:10:38
@article{d0569695-db30-4f56-905c-7d2a4ea86b09,
  abstract     = {{Background and purpose The role of synovitis and high fluid pressure in the loosening process after total hip arthroplasty has gained increasing attention. We investigated the correlation between head size, polyethylene wear, and capsular distention. Patients and methods We analyzed 39 unrevised, radiographically stable hips that had been operated with 28 or 32 mm femoral heads 10 years earlier because of osteoarthritis. We evaluated radiographic signs of loosening, linear and volumetric polyethylene wear, body mass index, activity level, and age. Sonographic examination was performed to measure capsular distance i.e. the distance between the prosthetic femoral neck and the anterior capsule. Results Linear wear was 0.09 mm/year and 0.18 mm/year in the 28 mm and 32 mm groups, respectively (p 0.001). The volumetric wear was 51 mm3/year and 136 mm3/year (p &lt; 0.001) and the capsular distance was 13 mm and 17 mm, respectively (p &lt; 0.001). There was a correlation between linear wear (r = 0.54), volumetric wear (r = 0.62), and capsular distance (p &lt; 0.001). Interpretation Wear was greater for the larger femoral head and was correlated to capsular distension.}},
  author       = {{Tarasevicius, Sarunas and Robertsson, Otto and Kesteris, Uldis and Kalesinskas, Romas Jonas and Wingstrand, Hans}},
  issn         = {{1745-3682}},
  language     = {{eng}},
  number       = {{4}},
  pages        = {{489--493}},
  publisher    = {{Taylor & Francis}},
  series       = {{Acta Orthopaedica}},
  title        = {{Effect of femoral head size on polyethylene wear and synovitis after total hip arthroplasty - A sonographic and radiographic study of 39 patients}},
  url          = {{http://dx.doi.org/10.1080/17453670710015472}},
  doi          = {{10.1080/17453670710015472}},
  volume       = {{79}},
  year         = {{2008}},
}