A rapid and sensitive liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method was developed and validated for the qualitative and quantitative assay of cyproheptadine (CP) in pharmaceutical samples. Diphenylpyraline hydrochloride (DPP) was used as an internal standard (IS). Two multiple reaction-monitoring (MRM) transitions for each analyte were observed: 288.1/96.1 and 288.1/191.2 for CP and 282.1/167.2 and 282.1/116.3 for DPP. The retention time of the drug was 7.29min. The analytical method was successfully validated for linearity (1-100ng/ml), intra-day precision, inter-day precision, and accuracy. The limit of detection (LOD) and limit of quantification (LOQ) were 0.86 and 0.98ng/ml, respectively. The proposed method was... (More)
A rapid and sensitive liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method was developed and validated for the qualitative and quantitative assay of cyproheptadine (CP) in pharmaceutical samples. Diphenylpyraline hydrochloride (DPP) was used as an internal standard (IS). Two multiple reaction-monitoring (MRM) transitions for each analyte were observed: 288.1/96.1 and 288.1/191.2 for CP and 282.1/167.2 and 282.1/116.3 for DPP. The retention time of the drug was 7.29min. The analytical method was successfully validated for linearity (1-100ng/ml), intra-day precision, inter-day precision, and accuracy. The limit of detection (LOD) and limit of quantification (LOQ) were 0.86 and 0.98ng/ml, respectively. The proposed method was applied to analyse the cyproheptadine content from seven different syrup formulations. (Less)
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Journal of Pharmaceutical and Biomedical Analysis
volume
50
pages
1044 - 1049
publisher
Elsevier
external identifiers
  • wos:000270759600054
  • pmid:19574011
  • scopus:70349189156
ISSN
0731-7085
DOI
10.1016/j.jpba.2009.06.006
language
English
LU publication?
yes
id
d27f7ab4-05d9-4727-a3de-86f8164a5ba1 (old id 1453442)
date added to LUP
2016-04-01 12:14:43
date last changed
2022-01-27 00:55:16
@article{d27f7ab4-05d9-4727-a3de-86f8164a5ba1,
  abstract     = {{A rapid and sensitive liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method was developed and validated for the qualitative and quantitative assay of cyproheptadine (CP) in pharmaceutical samples. Diphenylpyraline hydrochloride (DPP) was used as an internal standard (IS). Two multiple reaction-monitoring (MRM) transitions for each analyte were observed: 288.1/96.1 and 288.1/191.2 for CP and 282.1/167.2 and 282.1/116.3 for DPP. The retention time of the drug was 7.29min. The analytical method was successfully validated for linearity (1-100ng/ml), intra-day precision, inter-day precision, and accuracy. The limit of detection (LOD) and limit of quantification (LOQ) were 0.86 and 0.98ng/ml, respectively. The proposed method was applied to analyse the cyproheptadine content from seven different syrup formulations.}},
  author       = {{Feás, Xesús and Ye, Lei and Hosseini, Seyed V and Fente, Cristina A and Cepeda, Alberto}},
  issn         = {{0731-7085}},
  language     = {{eng}},
  pages        = {{1044--1049}},
  publisher    = {{Elsevier}},
  series       = {{Journal of Pharmaceutical and Biomedical Analysis}},
  title        = {{Development and validation of LC-MS/MS method for the determination of cyproheptadine in several pharmaceutical syrup formulations.}},
  url          = {{http://dx.doi.org/10.1016/j.jpba.2009.06.006}},
  doi          = {{10.1016/j.jpba.2009.06.006}},
  volume       = {{50}},
  year         = {{2009}},
}