Dual-pump dual-broadband coherent anti-Stokes Raman scattering in reacting flows

Roy, S ; Meyer, TR ; Lucht, RP ; Afzelius, Mikael LU ; Bengtsson, Per-Erik LU orcid and Gord, JR (2004) In Optics Letters 29(16). p.1843-1845
Abstract
A dual-pump, dual-broadband coherent anti-Stokes Raman scattering system for simultaneous measurements of temperature and concentrations of N-2, O-2, and CO2 in reacting flows is demonstrated. In this system pure rotational transitions of N-2-O-2 and rovibrational transitions of N-2-CO2 are probed simultaneously with two narrowband pump beams, a broadband pump beam, and a broadband Stokes beam. The main advantage of this technique is that it permits accurate temperature measurements at both low and high temperatures as well as concentration measurements of three molecules. (C) 2004 Optical Society of America.
Please use this url to cite or link to this publication:
author
; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Optics Letters
volume
29
issue
16
pages
1843 - 1845
publisher
Optical Society of America
external identifiers
  • wos:000223074600003
  • pmid:15357334
  • scopus:4043120975
ISSN
0146-9592
language
English
LU publication?
yes
id
d71cd391-34e8-467b-89e8-2c9bec67a929 (old id 271089)
alternative location
http://www.opticsinfobase.org/abstract.cfm?URI=ol-29-16-1843
date added to LUP
2016-04-01 16:24:38
date last changed
2022-01-28 19:28:42
@article{d71cd391-34e8-467b-89e8-2c9bec67a929,
  abstract     = {{A dual-pump, dual-broadband coherent anti-Stokes Raman scattering system for simultaneous measurements of temperature and concentrations of N-2, O-2, and CO2 in reacting flows is demonstrated. In this system pure rotational transitions of N-2-O-2 and rovibrational transitions of N-2-CO2 are probed simultaneously with two narrowband pump beams, a broadband pump beam, and a broadband Stokes beam. The main advantage of this technique is that it permits accurate temperature measurements at both low and high temperatures as well as concentration measurements of three molecules. (C) 2004 Optical Society of America.}},
  author       = {{Roy, S and Meyer, TR and Lucht, RP and Afzelius, Mikael and Bengtsson, Per-Erik and Gord, JR}},
  issn         = {{0146-9592}},
  language     = {{eng}},
  number       = {{16}},
  pages        = {{1843--1845}},
  publisher    = {{Optical Society of America}},
  series       = {{Optics Letters}},
  title        = {{Dual-pump dual-broadband coherent anti-Stokes Raman scattering in reacting flows}},
  url          = {{http://www.opticsinfobase.org/abstract.cfm?URI=ol-29-16-1843}},
  volume       = {{29}},
  year         = {{2004}},
}