A pre-sample charge measurement system for quantitative NMP-analysis
(2010) 19th International Conference on Ion Beam Analysis 268(11-12). p.1727-1730- Abstract
- In many IBA applications the main aim is to obtain quantitative figures characterizing the sample. Normally charge, i.e. number of probe particles, is used for normalization and is measured either by collecting the charge deposited in the sample or by collecting the particle in a post-sample Faraday cup or in combination. Both these techniques have drawbacks and results can be difficult to compare for samples with different matrix composition. In this work, we present an upgraded design and test results from the Lund NMP pre-sample charge measurement system. The system presented is based on a pre-sample beam deflection controlled by the beam scanning system for the nuclear microprobe. It can be operated in different modes, but during... (More)
- In many IBA applications the main aim is to obtain quantitative figures characterizing the sample. Normally charge, i.e. number of probe particles, is used for normalization and is measured either by collecting the charge deposited in the sample or by collecting the particle in a post-sample Faraday cup or in combination. Both these techniques have drawbacks and results can be difficult to compare for samples with different matrix composition. In this work, we present an upgraded design and test results from the Lund NMP pre-sample charge measurement system. The system presented is based on a pre-sample beam deflection controlled by the beam scanning system for the nuclear microprobe. It can be operated in different modes, but during normal operation the beam is blanked once per pixel and the corresponding charge is collected during the beam-off period. The system does not only measure an average of the beam current during data collection, but actually a pixel-by-pixel normalization is possible. Data of the system performance are presented and in addition illustrations of how quantitative measurements both for PIXE and elastic scattering can be made more reliable. (C) 2010 Elsevier B.V. All rights reserved. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1630875
- author
- Kristiansson, Per LU ; Borysiuk, Maciek LU ; Arteaga, Natalia LU ; Elfman, Mikael LU ; Fors, Erik LU ; Nilsson, Charlotta LU and Pallon, Jan LU
- organization
- publishing date
- 2010
- type
- Chapter in Book/Report/Conference proceeding
- publication status
- published
- subject
- keywords
- Faraday cup, Charge measurement, Nuclear microprobe, Quantitative, Beam blanker, analysis
- host publication
- Nuclear Instruments & Methods in Physics Research Section B-Beam Interactions with Materials and Atoms
- volume
- 268
- issue
- 11-12
- pages
- 1727 - 1730
- publisher
- Elsevier
- conference name
- 19th International Conference on Ion Beam Analysis
- conference dates
- 2009-09-07 - 2009-09-11
- external identifiers
-
- wos:000278702300007
- scopus:77953137444
- ISSN
- 0168-583X
- DOI
- 10.1016/j.nimb.2010.02.119
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Nuclear Physics (Faculty of Technology) (011013007)
- id
- d794a332-e477-40dc-924b-03b24cbc0a46 (old id 1630875)
- date added to LUP
- 2016-04-01 15:00:16
- date last changed
- 2022-01-28 03:32:13
@inproceedings{d794a332-e477-40dc-924b-03b24cbc0a46, abstract = {{In many IBA applications the main aim is to obtain quantitative figures characterizing the sample. Normally charge, i.e. number of probe particles, is used for normalization and is measured either by collecting the charge deposited in the sample or by collecting the particle in a post-sample Faraday cup or in combination. Both these techniques have drawbacks and results can be difficult to compare for samples with different matrix composition. In this work, we present an upgraded design and test results from the Lund NMP pre-sample charge measurement system. The system presented is based on a pre-sample beam deflection controlled by the beam scanning system for the nuclear microprobe. It can be operated in different modes, but during normal operation the beam is blanked once per pixel and the corresponding charge is collected during the beam-off period. The system does not only measure an average of the beam current during data collection, but actually a pixel-by-pixel normalization is possible. Data of the system performance are presented and in addition illustrations of how quantitative measurements both for PIXE and elastic scattering can be made more reliable. (C) 2010 Elsevier B.V. All rights reserved.}}, author = {{Kristiansson, Per and Borysiuk, Maciek and Arteaga, Natalia and Elfman, Mikael and Fors, Erik and Nilsson, Charlotta and Pallon, Jan}}, booktitle = {{Nuclear Instruments & Methods in Physics Research Section B-Beam Interactions with Materials and Atoms}}, issn = {{0168-583X}}, keywords = {{Faraday cup; Charge measurement; Nuclear microprobe; Quantitative; Beam blanker; analysis}}, language = {{eng}}, number = {{11-12}}, pages = {{1727--1730}}, publisher = {{Elsevier}}, title = {{A pre-sample charge measurement system for quantitative NMP-analysis}}, url = {{http://dx.doi.org/10.1016/j.nimb.2010.02.119}}, doi = {{10.1016/j.nimb.2010.02.119}}, volume = {{268}}, year = {{2010}}, }