Technical Note: MRI only prostate radiotherapy planning using the statistical decomposition algorithm.
(2015) In Medical Physics 42(10). p.6090-6097- Abstract
- In order to enable a magnetic resonance imaging (MRI) only workflow in radiotherapy treatment planning, methods are required for generating Hounsfield unit (HU) maps (i.e., synthetic computed tomography, sCT) for dose calculations, directly from MRI. The Statistical Decomposition Algorithm (SDA) is a method for automatically generating sCT images from a single MR image volume, based on automatic tissue classification in combination with a model trained using a multimodal template material. This study compares dose calculations between sCT generated by the SDA and conventional CT in the male pelvic region.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/8159100
- author
- Siversson, Carl
LU
; Nordström, Fredrik
LU
; Nilsson, Terese
; Nyholm, Tufve
; Jonsson, Joakim
; Gunnlaugsson, Adalsteinn
LU
and Olsson, Lars E
LU
- organization
- publishing date
- 2015
- type
- Contribution to journal
- publication status
- published
- subject
- in
- Medical Physics
- volume
- 42
- issue
- 10
- pages
- 6090 - 6097
- publisher
- John Wiley & Sons Inc.
- external identifiers
-
- pmid:26429284
- wos:000362570100053
- scopus:84942893075
- pmid:26429284
- ISSN
- 0094-2405
- DOI
- 10.1118/1.4931417
- language
- English
- LU publication?
- yes
- id
- d872b093-44a1-495f-8d8b-f13e7e96728a (old id 8159100)
- alternative location
- http://www.ncbi.nlm.nih.gov/pubmed/26429284?dopt=Abstract
- date added to LUP
- 2016-04-01 14:23:45
- date last changed
- 2025-04-04 14:03:53
@article{d872b093-44a1-495f-8d8b-f13e7e96728a, abstract = {{In order to enable a magnetic resonance imaging (MRI) only workflow in radiotherapy treatment planning, methods are required for generating Hounsfield unit (HU) maps (i.e., synthetic computed tomography, sCT) for dose calculations, directly from MRI. The Statistical Decomposition Algorithm (SDA) is a method for automatically generating sCT images from a single MR image volume, based on automatic tissue classification in combination with a model trained using a multimodal template material. This study compares dose calculations between sCT generated by the SDA and conventional CT in the male pelvic region.}}, author = {{Siversson, Carl and Nordström, Fredrik and Nilsson, Terese and Nyholm, Tufve and Jonsson, Joakim and Gunnlaugsson, Adalsteinn and Olsson, Lars E}}, issn = {{0094-2405}}, language = {{eng}}, number = {{10}}, pages = {{6090--6097}}, publisher = {{John Wiley & Sons Inc.}}, series = {{Medical Physics}}, title = {{Technical Note: MRI only prostate radiotherapy planning using the statistical decomposition algorithm.}}, url = {{http://dx.doi.org/10.1118/1.4931417}}, doi = {{10.1118/1.4931417}}, volume = {{42}}, year = {{2015}}, }