Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Computerized perimetry in glaucoma management

Heijl, A LU (1989) In Acta Ophthalmologica 67(1). p.1-12
Abstract

The present article discusses the role of computerized perimetry in the management of patients with suspect and manifest glaucoma. The value of visual field examination is compared to that of inspection and photography of the optic disc and to some extent to retinal nerve fibre layer photography. Computerized perimetry is related to standard manual visual field examination. Guidelines are offered for the choice of test programs and for the interpretation of results.

Please use this url to cite or link to this publication:
author
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Computers, Glaucoma/diagnosis, Humans, Intraocular Pressure, Nerve Fibers/pathology, Optic Disk/pathology, Retina/pathology, Tonometry, Ocular, Visual Field Tests/methods, Visual Fields
in
Acta Ophthalmologica
volume
67
issue
1
pages
12 pages
publisher
Wiley-Blackwell
external identifiers
  • pmid:2672693
  • scopus:0024599051
ISSN
0001-639X
DOI
10.1111/j.1755-3768.1989.tb00716.x
language
English
LU publication?
yes
id
dff06eec-79bb-4fb2-838e-5bf7010b3516
date added to LUP
2019-06-30 16:20:08
date last changed
2024-01-01 14:44:17
@article{dff06eec-79bb-4fb2-838e-5bf7010b3516,
  abstract     = {{<p>The present article discusses the role of computerized perimetry in the management of patients with suspect and manifest glaucoma. The value of visual field examination is compared to that of inspection and photography of the optic disc and to some extent to retinal nerve fibre layer photography. Computerized perimetry is related to standard manual visual field examination. Guidelines are offered for the choice of test programs and for the interpretation of results.</p>}},
  author       = {{Heijl, A}},
  issn         = {{0001-639X}},
  keywords     = {{Computers; Glaucoma/diagnosis; Humans; Intraocular Pressure; Nerve Fibers/pathology; Optic Disk/pathology; Retina/pathology; Tonometry, Ocular; Visual Field Tests/methods; Visual Fields}},
  language     = {{eng}},
  number       = {{1}},
  pages        = {{1--12}},
  publisher    = {{Wiley-Blackwell}},
  series       = {{Acta Ophthalmologica}},
  title        = {{Computerized perimetry in glaucoma management}},
  url          = {{http://dx.doi.org/10.1111/j.1755-3768.1989.tb00716.x}},
  doi          = {{10.1111/j.1755-3768.1989.tb00716.x}},
  volume       = {{67}},
  year         = {{1989}},
}