Influence of the cavity field flatness and effect of the phase reference line errorson the beam dynamics of the ESS LINAC

De Prisco, R. LU ; Zeng, R. LU ; Czuba, K. ; Leśniak, T. ; Papis, R. ; Sikora, D. and Zukociński, M. (2018) 61st ICFA Advanced Beam Dynamics Workshop on High-Intensity and High-Brightness Hadron Beams, HB2018 p.377-382
Abstract

The particle longitudinal dynamics is affected by errors on the phase and amplitude of the electro-magnetic field in each cavity that cause emittance growth, beam degradation and losses. One of the causes of the phase error is the change of the ambience temperature in the LINAC tunnel, in the stub and in the klystron gallery that induces a phase drift of the signal travelling through the cables and radio frequency components. The field flatness error of each multiple cell cavity is caused by volume perturbation, cell to cell coupling, tuner penetration, etc. In this paper the influences of these two types of errors on the beam dynamics are studied and tolerances for keeping beam quality within acceptable limits are determined.

Please use this url to cite or link to this publication:
author
; ; ; ; ; and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
host publication
HB2018 : Proceedings of the 61st ICFA Advanced Beam Dynamics Workshop on High-Intensity and High-Brightness Hadron Beams - Proceedings of the 61st ICFA Advanced Beam Dynamics Workshop on High-Intensity and High-Brightness Hadron Beams
editor
RW Schaa, Volker
pages
6 pages
publisher
JACoW Publishing
conference name
61st ICFA Advanced Beam Dynamics Workshop on High-Intensity and High-Brightness Hadron Beams, HB2018
conference location
Daejeon, Korea, Republic of
conference dates
2018-06-17 - 2018-06-22
external identifiers
  • scopus:85081066792
ISBN
9783954502028
DOI
10.18429/JACoW-HB2018-THP2WB03
language
English
LU publication?
yes
id
dff26c3a-db5a-4dbf-b87b-eedda2e92368
date added to LUP
2020-03-26 14:51:30
date last changed
2022-02-01 05:15:19
@inproceedings{dff26c3a-db5a-4dbf-b87b-eedda2e92368,
  abstract     = {{<p>The particle longitudinal dynamics is affected by errors on the phase and amplitude of the electro-magnetic field in each cavity that cause emittance growth, beam degradation and losses. One of the causes of the phase error is the change of the ambience temperature in the LINAC tunnel, in the stub and in the klystron gallery that induces a phase drift of the signal travelling through the cables and radio frequency components. The field flatness error of each multiple cell cavity is caused by volume perturbation, cell to cell coupling, tuner penetration, etc. In this paper the influences of these two types of errors on the beam dynamics are studied and tolerances for keeping beam quality within acceptable limits are determined.</p>}},
  author       = {{De Prisco, R. and Zeng, R. and Czuba, K. and Leśniak, T. and Papis, R. and Sikora, D. and Zukociński, M.}},
  booktitle    = {{HB2018 : Proceedings of the 61st ICFA Advanced Beam Dynamics Workshop on High-Intensity and High-Brightness Hadron Beams}},
  editor       = {{RW Schaa, Volker}},
  isbn         = {{9783954502028}},
  language     = {{eng}},
  pages        = {{377--382}},
  publisher    = {{JACoW Publishing}},
  title        = {{Influence of the cavity field flatness and effect of the phase reference line errorson the beam dynamics of the ESS LINAC}},
  url          = {{http://dx.doi.org/10.18429/JACoW-HB2018-THP2WB03}},
  doi          = {{10.18429/JACoW-HB2018-THP2WB03}},