Measurements of cardiac output and organ blood flow in rats using 99Tcm labelled microspheres
(1979) In Acta Physiologica Scandinavica 106(2). p.123-128- Abstract
The cardiac output and regional blood flow have been simultaneously determined in the anesthetized rat by using the reference organ method. 99Tcm labelled dextran 15 μm microspheres were injected in the left ventricle while simultaneously an arterial reference sample was drawn at constant known rate. The values calculated regarding cardiac output agree well with previously recorded series. Regional organ blood flow in the rat is presented as ml. min‐1. g‐1 tissue and values do agree with those reported by others. The results indicate that the reference organ method can be used in the rat for the study of cardiac output and regional blood flow.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/e28dc324-f098-4630-b294-09748696b7c6
- author
- HAFSTRÖM, LARSOLOF ; PERSSON, BERTIL LU and SUNDQVIST, KAJ
- organization
- publishing date
- 1979-01-01
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- Technetium, blood flow, cardiac output, Microspheres
- in
- Acta Physiologica Scandinavica
- volume
- 106
- issue
- 2
- pages
- 6 pages
- publisher
- Wiley-Blackwell
- external identifiers
-
- pmid:388984
- scopus:0018645563
- ISSN
- 0001-6772
- DOI
- 10.1111/j.1748-1716.1979.tb06380.x
- language
- English
- LU publication?
- yes
- id
- e28dc324-f098-4630-b294-09748696b7c6
- date added to LUP
- 2020-08-15 17:30:20
- date last changed
- 2024-01-02 17:03:46
@article{e28dc324-f098-4630-b294-09748696b7c6, abstract = {{<p>The cardiac output and regional blood flow have been simultaneously determined in the anesthetized rat by using the reference organ method. <sup>99</sup>Tc<sup>m</sup> labelled dextran 15 μm microspheres were injected in the left ventricle while simultaneously an arterial reference sample was drawn at constant known rate. The values calculated regarding cardiac output agree well with previously recorded series. Regional organ blood flow in the rat is presented as ml. min<sup>‐1</sup>. g<sup>‐1</sup> tissue and values do agree with those reported by others. The results indicate that the reference organ method can be used in the rat for the study of cardiac output and regional blood flow.</p>}}, author = {{HAFSTRÖM, LARSOLOF and PERSSON, BERTIL and SUNDQVIST, KAJ}}, issn = {{0001-6772}}, keywords = {{Technetium; blood flow; cardiac output; Microspheres}}, language = {{eng}}, month = {{01}}, number = {{2}}, pages = {{123--128}}, publisher = {{Wiley-Blackwell}}, series = {{Acta Physiologica Scandinavica}}, title = {{Measurements of cardiac output and organ blood flow in rats using <sup>99</sup>Tc<sup>m</sup> labelled microspheres}}, url = {{http://dx.doi.org/10.1111/j.1748-1716.1979.tb06380.x}}, doi = {{10.1111/j.1748-1716.1979.tb06380.x}}, volume = {{106}}, year = {{1979}}, }