Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Prevalence of dermatitis including allergic contact dermatitis from medical devices used by children and adults with Type 1 diabetes mellitus : A systematic review and questionnaire study

von Kobyletzki, L. B. LU ; Ulriksdotter, J. LU orcid ; Sukakul, T. LU orcid ; Aerts, O. ; Agner, T. ; Buhl, T. ; Bruze, M. LU ; Foti, C. ; Gimenez-Arnau, A. and Gonçalo, M. , et al. (2024) In Journal of the European Academy of Dermatology and Venereology
Abstract

Use of medical devices (MDs), that is, glucose sensors and insulin pumps, in patients with Type 1 diabetes mellitus (T1D) has proven an enormous advantage for disease control. Adverse skin reactions from these MDs may however hamper compliance. The objective of this study was to systematically review and analyse studies assessing the prevalence and incidence of dermatitis, including allergic contact dermatitis (ACD) related to MDs used in patients with T1D and to compare referral routes and the clinical investigation routines between clinics being part of the European Environmental and Contact Dermatitis Research Group (EECDRG). A systematic search of PubMed, EMBASE, CINAHL and Cochrane databases of full-text studies reporting incidence... (More)

Use of medical devices (MDs), that is, glucose sensors and insulin pumps, in patients with Type 1 diabetes mellitus (T1D) has proven an enormous advantage for disease control. Adverse skin reactions from these MDs may however hamper compliance. The objective of this study was to systematically review and analyse studies assessing the prevalence and incidence of dermatitis, including allergic contact dermatitis (ACD) related to MDs used in patients with T1D and to compare referral routes and the clinical investigation routines between clinics being part of the European Environmental and Contact Dermatitis Research Group (EECDRG). A systematic search of PubMed, EMBASE, CINAHL and Cochrane databases of full-text studies reporting incidence and prevalence of dermatitis in persons with T1D using MDs was conducted until December 2021. The Newcastle–Ottawa Scale was used to assess study quality. The inventory performed at EECRDG clinics focused on referral routes, patient numbers and the diagnostic process. Among the 3145 screened abstracts, 39 studies fulfilled the inclusion criteria. Sixteen studies included data on children only, 14 studies were on adults and nine studies reported data on both children and adults. Participants were exposed to a broad range of devices. Skin reactions were rarely specified. It was found that both the diagnostic process and referral routes differ in different centres. Further data on the prevalence of skin reactions related to MDs in individuals with T1D is needed and particularly studies where the skin reactions are correctly diagnosed. A correct diagnosis is delayed or hampered by the fact that, at present, the actual substances within the MDs are not declared, are changed without notice and the commercially available test materials are not adequately updated. Within Europe, routines for referral should be made more standardized to improve the diagnostic procedure when investigating patients with possible ACD from MDs.

(Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; ; and , et al. (More)
; ; ; ; ; ; ; ; ; ; ; ; ; ; and (Less)
organization
publishing date
type
Contribution to journal
publication status
epub
subject
in
Journal of the European Academy of Dermatology and Venereology
publisher
Elsevier
external identifiers
  • pmid:38400603
  • scopus:85186488031
ISSN
0926-9959
DOI
10.1111/jdv.19908
language
English
LU publication?
yes
id
e583c6d3-a288-483b-95e0-b51065c5d042
date added to LUP
2024-03-21 15:19:30
date last changed
2024-04-18 15:47:39
@article{e583c6d3-a288-483b-95e0-b51065c5d042,
  abstract     = {{<p>Use of medical devices (MDs), that is, glucose sensors and insulin pumps, in patients with Type 1 diabetes mellitus (T1D) has proven an enormous advantage for disease control. Adverse skin reactions from these MDs may however hamper compliance. The objective of this study was to systematically review and analyse studies assessing the prevalence and incidence of dermatitis, including allergic contact dermatitis (ACD) related to MDs used in patients with T1D and to compare referral routes and the clinical investigation routines between clinics being part of the European Environmental and Contact Dermatitis Research Group (EECDRG). A systematic search of PubMed, EMBASE, CINAHL and Cochrane databases of full-text studies reporting incidence and prevalence of dermatitis in persons with T1D using MDs was conducted until December 2021. The Newcastle–Ottawa Scale was used to assess study quality. The inventory performed at EECRDG clinics focused on referral routes, patient numbers and the diagnostic process. Among the 3145 screened abstracts, 39 studies fulfilled the inclusion criteria. Sixteen studies included data on children only, 14 studies were on adults and nine studies reported data on both children and adults. Participants were exposed to a broad range of devices. Skin reactions were rarely specified. It was found that both the diagnostic process and referral routes differ in different centres. Further data on the prevalence of skin reactions related to MDs in individuals with T1D is needed and particularly studies where the skin reactions are correctly diagnosed. A correct diagnosis is delayed or hampered by the fact that, at present, the actual substances within the MDs are not declared, are changed without notice and the commercially available test materials are not adequately updated. Within Europe, routines for referral should be made more standardized to improve the diagnostic procedure when investigating patients with possible ACD from MDs.</p>}},
  author       = {{von Kobyletzki, L. B. and Ulriksdotter, J. and Sukakul, T. and Aerts, O. and Agner, T. and Buhl, T. and Bruze, M. and Foti, C. and Gimenez-Arnau, A. and Gonçalo, M. and Hamnerius, N. and Johansen, J. D. and Rustemeyer, T. and Stingeni, L. and Wilkinson, M. and Svedman, C.}},
  issn         = {{0926-9959}},
  language     = {{eng}},
  publisher    = {{Elsevier}},
  series       = {{Journal of the European Academy of Dermatology and Venereology}},
  title        = {{Prevalence of dermatitis including allergic contact dermatitis from medical devices used by children and adults with Type 1 diabetes mellitus : A systematic review and questionnaire study}},
  url          = {{http://dx.doi.org/10.1111/jdv.19908}},
  doi          = {{10.1111/jdv.19908}},
  year         = {{2024}},
}