Saturated pool boiling heat transfer of acetone and HFE-7200 on modified surfaces by electrophoretic and electrochemical deposition

Wu, Zan LU ; Cao, Zhen LU and Sundén, Bengt LU (2019) In Applied Energy 249. p.286-299
Abstract

Boiling heat transfer intensification is of big relevance to energy conversion and conservation, materials and resources saving, and electronics cooling. This work aims to enhance saturated pool boiling of well-wetting liquids, i.e., acetone and HFE-7200 on nanoparticles-deposited surfaces by electrophoretic deposition and on microporous foam surfaces by electrochemical deposition. The electrophoretic-deposited surfaces enhance the heat transfer coefficient of acetone and HFE-7200 by up to 70% and 190%, respectively. However, the critical heat flux is not improved on electrophoretic-deposited surfaces. The electrochemical-deposited surfaces increase the boiling heat transfer coefficient by up to 370% and the critical heat flux by more... (More)

Boiling heat transfer intensification is of big relevance to energy conversion and conservation, materials and resources saving, and electronics cooling. This work aims to enhance saturated pool boiling of well-wetting liquids, i.e., acetone and HFE-7200 on nanoparticles-deposited surfaces by electrophoretic deposition and on microporous foam surfaces by electrochemical deposition. The electrophoretic-deposited surfaces enhance the heat transfer coefficient of acetone and HFE-7200 by up to 70% and 190%, respectively. However, the critical heat flux is not improved on electrophoretic-deposited surfaces. The electrochemical-deposited surfaces increase the boiling heat transfer coefficient by up to 370% and the critical heat flux by more than 30%. Bubble dynamics were visualized simultaneously. The bubble departure diameter from experiments can be predicted by a dynamic force balance model within a ±20% error band. A mechanistic heat transfer model was proposed for modified porous surfaces, including not only the heat fluxes from microlayer evaporation and transient conduction but also the heat flux from micro-convection due to liquid agitation and entrainment by growing and departing bubbles. The mechanistic heat transfer model can predict experimental pool boiling curves of acetone and HFE-7200 on electrophoretic-deposited and electrochemical-deposited surfaces relatively well, especially for the isolated bubble regime where most bubbles are isolated and bubble coalescence is not intensive. Besides, the critical heat flux of a modified surface can be estimated if the initial (maximum) wicked volume flux on the structured surface relative to the smooth surface is considered.

(Less)
Please use this url to cite or link to this publication:
author
; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
keywords
Critical heat flux, Heat transfer, Micro-convection, Pool boiling, Surface modification, Wickability
in
Applied Energy
volume
249
pages
14 pages
publisher
Elsevier
external identifiers
  • scopus:85065069128
ISSN
0306-2619
DOI
10.1016/j.apenergy.2019.04.160
language
English
LU publication?
yes
id
e73c046c-97e3-47cd-8b73-5bd5781ae0ce
date added to LUP
2019-05-13 09:24:34
date last changed
2023-11-18 21:22:19
@article{e73c046c-97e3-47cd-8b73-5bd5781ae0ce,
  abstract     = {{<p>Boiling heat transfer intensification is of big relevance to energy conversion and conservation, materials and resources saving, and electronics cooling. This work aims to enhance saturated pool boiling of well-wetting liquids, i.e., acetone and HFE-7200 on nanoparticles-deposited surfaces by electrophoretic deposition and on microporous foam surfaces by electrochemical deposition. The electrophoretic-deposited surfaces enhance the heat transfer coefficient of acetone and HFE-7200 by up to 70% and 190%, respectively. However, the critical heat flux is not improved on electrophoretic-deposited surfaces. The electrochemical-deposited surfaces increase the boiling heat transfer coefficient by up to 370% and the critical heat flux by more than 30%. Bubble dynamics were visualized simultaneously. The bubble departure diameter from experiments can be predicted by a dynamic force balance model within a ±20% error band. A mechanistic heat transfer model was proposed for modified porous surfaces, including not only the heat fluxes from microlayer evaporation and transient conduction but also the heat flux from micro-convection due to liquid agitation and entrainment by growing and departing bubbles. The mechanistic heat transfer model can predict experimental pool boiling curves of acetone and HFE-7200 on electrophoretic-deposited and electrochemical-deposited surfaces relatively well, especially for the isolated bubble regime where most bubbles are isolated and bubble coalescence is not intensive. Besides, the critical heat flux of a modified surface can be estimated if the initial (maximum) wicked volume flux on the structured surface relative to the smooth surface is considered.</p>}},
  author       = {{Wu, Zan and Cao, Zhen and Sundén, Bengt}},
  issn         = {{0306-2619}},
  keywords     = {{Critical heat flux; Heat transfer; Micro-convection; Pool boiling; Surface modification; Wickability}},
  language     = {{eng}},
  pages        = {{286--299}},
  publisher    = {{Elsevier}},
  series       = {{Applied Energy}},
  title        = {{Saturated pool boiling heat transfer of acetone and HFE-7200 on modified surfaces by electrophoretic and electrochemical deposition}},
  url          = {{http://dx.doi.org/10.1016/j.apenergy.2019.04.160}},
  doi          = {{10.1016/j.apenergy.2019.04.160}},
  volume       = {{249}},
  year         = {{2019}},
}