Rapid and effective CD3 T-cell depletion with a magnetic cell sorting program to produce peripheral blood progenitor cell products for haploidentical transplantation in children and adults.

Dykes, Josefina LU ; Toporski, Jacek LU ; Juliusson, Gunnar LU ; Békássy, Albert LU ; Lenhoff, Stig ; Lindmark, Anders LU and Scheding, Stefan LU (2007) In Transfusion 47(11). p.2134-2142
Abstract
BACKGROUND: Effective T-cell depletion is a prerequisite for haploidentical peripheral blood progenitor cell (PBPC) transplantation. This study was performed to investigate the performance of magnetic cell sorting–based direct large-scale T-cell depletion, which is an attractive alternative to standard PBPC enrichment procedures.



STUDY DESIGN AND METHODS: PBPCs were harvested from 11 human leukocyte antigen (HLA)-haploidentical donors. T cells labeled with anti-CD3–coated beads were depleted with a commercially available magnetic separation unit (CliniMACS, Miltenyi Biotec) with either the Depletion 2.1 (D2.1, n = 11) or the novel Depletion 3.1 (D3.1, n = 12) program. If indicated, additional CD34+ selections were... (More)
BACKGROUND: Effective T-cell depletion is a prerequisite for haploidentical peripheral blood progenitor cell (PBPC) transplantation. This study was performed to investigate the performance of magnetic cell sorting–based direct large-scale T-cell depletion, which is an attractive alternative to standard PBPC enrichment procedures.



STUDY DESIGN AND METHODS: PBPCs were harvested from 11 human leukocyte antigen (HLA)-haploidentical donors. T cells labeled with anti-CD3–coated beads were depleted with a commercially available magnetic separation unit (CliniMACS, Miltenyi Biotec) with either the Depletion 2.1 (D2.1, n = 11) or the novel Depletion 3.1 (D3.1, n = 12) program. If indicated, additional CD34+ selections were performed (n = 6). Eleven patients received T-cell-depleted grafts after reduced-intensity conditioning.



RESULTS: The median log T-cell depletion was better with the D2.1 compared to the D3.1 (log 3.6 vs. log 2.3, p < 0.05) and was further improved by introducing an immunoglobulin G (IgG)-blocking step (log 4.5 and log 3.4, respectively). The D3.1 was superior to the D2.1 (p < 0.05) in median recovery of CD34+ cells (90% vs. 78%) and in median recovery of CD3– cells (87% vs. 76%). The median processing times per 1010 total cells were 0.90 hours (D2.1) and 0.35 hours (D3.1). The transplanted grafts (directly T-cell–depleted products with or without positively selected CD34+ cells) contained a median of 10.5 × 106 per kg CD34+, 0.93 × 105 per kg CD3+, and 11.6 × 106 per kg CD56+. Rapid engraftment was achieved in 10 patients. The incidences of acute graft-versus-host disease were less than 10 percent (Grade I/II) and 0 percent (Grade III/IV).



CONCLUSION: The novel D3.1 program with IgG blocking enables highly effective, time-saving large-scale T-cell depletion. Combining direct depletion techniques with standard CD34+ selection enables the composition of grafts optimized to the specific requirements of the patients. (Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Transfusion
volume
47
issue
11
pages
2134 - 2142
publisher
Wiley-Blackwell
external identifiers
  • wos:000250364100024
  • scopus:35448978756
  • pmid:17958543
ISSN
1537-2995
DOI
10.1111/j.1537-2995.2007.01438.x
language
English
LU publication?
yes
id
e91ed18b-d46a-4a24-aa4f-872484a30567 (old id 608360)
alternative location
http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?cmd=Retrieve&db=PubMed&list_uids=17958543&dopt=Abstract
date added to LUP
2016-04-01 15:29:51
date last changed
2022-08-14 23:36:48
@article{e91ed18b-d46a-4a24-aa4f-872484a30567,
  abstract     = {{BACKGROUND: Effective T-cell depletion is a prerequisite for haploidentical peripheral blood progenitor cell (PBPC) transplantation. This study was performed to investigate the performance of magnetic cell sorting–based direct large-scale T-cell depletion, which is an attractive alternative to standard PBPC enrichment procedures.<br/><br>
<br/><br>
STUDY DESIGN AND METHODS: PBPCs were harvested from 11 human leukocyte antigen (HLA)-haploidentical donors. T cells labeled with anti-CD3–coated beads were depleted with a commercially available magnetic separation unit (CliniMACS, Miltenyi Biotec) with either the Depletion 2.1 (D2.1, n = 11) or the novel Depletion 3.1 (D3.1, n = 12) program. If indicated, additional CD34+ selections were performed (n = 6). Eleven patients received T-cell-depleted grafts after reduced-intensity conditioning.<br/><br>
<br/><br>
RESULTS: The median log T-cell depletion was better with the D2.1 compared to the D3.1 (log 3.6 vs. log 2.3, p &lt; 0.05) and was further improved by introducing an immunoglobulin G (IgG)-blocking step (log 4.5 and log 3.4, respectively). The D3.1 was superior to the D2.1 (p &lt; 0.05) in median recovery of CD34+ cells (90% vs. 78%) and in median recovery of CD3– cells (87% vs. 76%). The median processing times per 1010 total cells were 0.90 hours (D2.1) and 0.35 hours (D3.1). The transplanted grafts (directly T-cell–depleted products with or without positively selected CD34+ cells) contained a median of 10.5 × 106 per kg CD34+, 0.93 × 105 per kg CD3+, and 11.6 × 106 per kg CD56+. Rapid engraftment was achieved in 10 patients. The incidences of acute graft-versus-host disease were less than 10 percent (Grade I/II) and 0 percent (Grade III/IV).<br/><br>
<br/><br>
CONCLUSION: The novel D3.1 program with IgG blocking enables highly effective, time-saving large-scale T-cell depletion. Combining direct depletion techniques with standard CD34+ selection enables the composition of grafts optimized to the specific requirements of the patients.}},
  author       = {{Dykes, Josefina and Toporski, Jacek and Juliusson, Gunnar and Békássy, Albert and Lenhoff, Stig and Lindmark, Anders and Scheding, Stefan}},
  issn         = {{1537-2995}},
  language     = {{eng}},
  number       = {{11}},
  pages        = {{2134--2142}},
  publisher    = {{Wiley-Blackwell}},
  series       = {{Transfusion}},
  title        = {{Rapid and effective CD3 T-cell depletion with a magnetic cell sorting program to produce peripheral blood progenitor cell products for haploidentical transplantation in children and adults.}},
  url          = {{http://dx.doi.org/10.1111/j.1537-2995.2007.01438.x}},
  doi          = {{10.1111/j.1537-2995.2007.01438.x}},
  volume       = {{47}},
  year         = {{2007}},
}