Design, construction and commissionig of a NEG coated wiggler vacuum chamber for the LNLS storage ring

Ferreira, M. J. LU ; Ferraz, O. R. ; Filho, H. G. and Silva, M. B. (2005) Particle Accelerator Conference, PAC 2005 In Proceedings of the IEEE Particle Accelerator Conference 2005. p.2807-2808
Abstract

We present the design of the vacuum chamber for the LNLS 2T Hybrid Wiggler. The chamber is a 3m long, 1.2mm thick 316L SS tube, which was mechanically pressed into an elliptical shape from an originally round tube. In order to provide the necessary mechanical tolerances, the rather flexible tube is welded to lateral supports that run the complete length of the chamber. Special care has been given to the mechanical and magnetic characterization of the chamber and the inner surface of the chamber was NEG-coated at the ESRF. We present the installation procedure as well the vacuum conditioning charge evolution.

Please use this url to cite or link to this publication:
author
; ; and
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
host publication
Proceedings of the Particle Accelerator Conference, PAC 2005
series title
Proceedings of the IEEE Particle Accelerator Conference
volume
2005
pages
2 pages
publisher
IEEE Press
conference name
Particle Accelerator Conference, PAC 2005
conference location
Knoxville, TN, United States
conference dates
2005-05-16 - 2005-05-20
external identifiers
  • scopus:33847171996
ISBN
0780388593
9780780388598
DOI
10.1109/PAC.2005.1591276
language
English
LU publication?
no
id
e991edff-14b6-46bb-991f-5ed789dfd93f
date added to LUP
2025-01-26 11:47:45
date last changed
2025-04-04 14:07:16
@inproceedings{e991edff-14b6-46bb-991f-5ed789dfd93f,
  abstract     = {{<p>We present the design of the vacuum chamber for the LNLS 2T Hybrid Wiggler. The chamber is a 3m long, 1.2mm thick 316L SS tube, which was mechanically pressed into an elliptical shape from an originally round tube. In order to provide the necessary mechanical tolerances, the rather flexible tube is welded to lateral supports that run the complete length of the chamber. Special care has been given to the mechanical and magnetic characterization of the chamber and the inner surface of the chamber was NEG-coated at the ESRF. We present the installation procedure as well the vacuum conditioning charge evolution.</p>}},
  author       = {{Ferreira, M. J. and Ferraz, O. R. and Filho, H. G. and Silva, M. B.}},
  booktitle    = {{Proceedings of the Particle Accelerator Conference, PAC 2005}},
  isbn         = {{0780388593}},
  language     = {{eng}},
  pages        = {{2807--2808}},
  publisher    = {{IEEE Press}},
  series       = {{Proceedings of the IEEE Particle Accelerator Conference}},
  title        = {{Design, construction and commissionig of a NEG coated wiggler vacuum chamber for the LNLS storage ring}},
  url          = {{http://dx.doi.org/10.1109/PAC.2005.1591276}},
  doi          = {{10.1109/PAC.2005.1591276}},
  volume       = {{2005}},
  year         = {{2005}},
}