Ultrasound measurements of subcutaneous adipose tissue in infants are reproducible

Flygare, Annika ; Valentin, Lil LU orcid ; Karlsland Åkeson, Pia LU ; Flodmark, Carl-Erik LU ; Ivarsson, S.A. and Axelsson, Irene LU (1999) In Journal of Pediatric Gastroenterology and Nutrition - Jpgn 28(5). p.492-494
Abstract
BACKGROUND: The purpose of this study was to evaluate the ultrasound technique for measuring subcutaneous adipose tissue in infants. METHODS: Twenty infants were investigated at 3, 6, and 12 months of age. All measurements were made by the same investigator in triplicate on the left side of the body at the triceps and subscapular anatomic landmarks and at the abdomen and thigh. An ultrasound system equipped with a linear 7.0-MHz transducer was used. RESULTS: The intraclass correlation coefficients were 0.88 to 0.99. Random errors ranged from 0.01 to 0.19 mm. For log-transformed values, the random error ranged from 2.4% to 5.7%. CONCLUSIONS: Measurements of subcutaneous fat in infants using ultrasound are reproducible when performed by the... (More)
BACKGROUND: The purpose of this study was to evaluate the ultrasound technique for measuring subcutaneous adipose tissue in infants. METHODS: Twenty infants were investigated at 3, 6, and 12 months of age. All measurements were made by the same investigator in triplicate on the left side of the body at the triceps and subscapular anatomic landmarks and at the abdomen and thigh. An ultrasound system equipped with a linear 7.0-MHz transducer was used. RESULTS: The intraclass correlation coefficients were 0.88 to 0.99. Random errors ranged from 0.01 to 0.19 mm. For log-transformed values, the random error ranged from 2.4% to 5.7%. CONCLUSIONS: Measurements of subcutaneous fat in infants using ultrasound are reproducible when performed by the same observer. (Less)
Please use this url to cite or link to this publication:
author
; ; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Journal of Pediatric Gastroenterology and Nutrition - Jpgn
volume
28
issue
5
pages
492 - 494
publisher
Lippincott Williams & Wilkins
external identifiers
  • scopus:0033512121
ISSN
1536-4801
language
English
LU publication?
yes
id
ea9e2746-6512-4b30-9940-b5438b3195f0 (old id 1115542)
date added to LUP
2016-04-01 12:18:11
date last changed
2022-01-27 01:45:09
@article{ea9e2746-6512-4b30-9940-b5438b3195f0,
  abstract     = {{BACKGROUND: The purpose of this study was to evaluate the ultrasound technique for measuring subcutaneous adipose tissue in infants. METHODS: Twenty infants were investigated at 3, 6, and 12 months of age. All measurements were made by the same investigator in triplicate on the left side of the body at the triceps and subscapular anatomic landmarks and at the abdomen and thigh. An ultrasound system equipped with a linear 7.0-MHz transducer was used. RESULTS: The intraclass correlation coefficients were 0.88 to 0.99. Random errors ranged from 0.01 to 0.19 mm. For log-transformed values, the random error ranged from 2.4% to 5.7%. CONCLUSIONS: Measurements of subcutaneous fat in infants using ultrasound are reproducible when performed by the same observer.}},
  author       = {{Flygare, Annika and Valentin, Lil and Karlsland Åkeson, Pia and Flodmark, Carl-Erik and Ivarsson, S.A. and Axelsson, Irene}},
  issn         = {{1536-4801}},
  language     = {{eng}},
  number       = {{5}},
  pages        = {{492--494}},
  publisher    = {{Lippincott Williams & Wilkins}},
  series       = {{Journal of Pediatric Gastroenterology and Nutrition - Jpgn}},
  title        = {{Ultrasound measurements of subcutaneous adipose tissue in infants are reproducible}},
  volume       = {{28}},
  year         = {{1999}},
}