Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

SU-8 Cantilever for Bio/chemical Sensing; Fabrication, Characterisation and Development of Novel Read-out Methods

Nordström, Maria LU ; Keller, Stephan ; Lillemose, Michael ; Johansson, Alicia ; Dohn, Søren ; Haefliger, Daniel ; Blagoi, Gabriela ; Havsteen-Jakobsen, Mogens and Boisen, Anja (2008) In Sensors 8(3). p.1595-1612
Abstract
Here, we present the activities within our research group over the last five yearswith cantilevers fabricated in the polymer SU-8. We believe that SU-8 is an interestingpolymer for fabrication of cantilevers for bio/chemical sensing due to its simple processingand low Young’s modulus. We show examples of different integrated read-out methodsand their characterisation. We also show that SU-8 cantilevers have a reduced sensitivity tochanges in the environmental temperature and pH of the buffer solution. Moreover, weshow that the SU-8 cantilever surface can be functionalised directly with receptormolecules for analyte detection, thereby avoiding gold-thiol chemistry.
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; and
publishing date
type
Contribution to journal
publication status
published
subject
in
Sensors
volume
8
issue
3
pages
1595 - 1612
publisher
MDPI AG
external identifiers
  • scopus:41549120284
ISSN
1424-8220
DOI
10.3390/s8031595
language
English
LU publication?
no
additional info
Invited Review Article
id
ee9d6397-260a-4b6e-a6b2-a3bf6987f57d (old id 3130342)
date added to LUP
2016-04-01 13:57:11
date last changed
2022-04-06 07:56:10
@article{ee9d6397-260a-4b6e-a6b2-a3bf6987f57d,
  abstract     = {{Here, we present the activities within our research group over the last five yearswith cantilevers fabricated in the polymer SU-8. We believe that SU-8 is an interestingpolymer for fabrication of cantilevers for bio/chemical sensing due to its simple processingand low Young’s modulus. We show examples of different integrated read-out methodsand their characterisation. We also show that SU-8 cantilevers have a reduced sensitivity tochanges in the environmental temperature and pH of the buffer solution. Moreover, weshow that the SU-8 cantilever surface can be functionalised directly with receptormolecules for analyte detection, thereby avoiding gold-thiol chemistry.}},
  author       = {{Nordström, Maria and Keller, Stephan and Lillemose, Michael and Johansson, Alicia and Dohn, Søren and Haefliger, Daniel and Blagoi, Gabriela and Havsteen-Jakobsen, Mogens and Boisen, Anja}},
  issn         = {{1424-8220}},
  language     = {{eng}},
  number       = {{3}},
  pages        = {{1595--1612}},
  publisher    = {{MDPI AG}},
  series       = {{Sensors}},
  title        = {{SU-8 Cantilever for Bio/chemical Sensing; Fabrication, Characterisation and Development of Novel Read-out Methods}},
  url          = {{http://dx.doi.org/10.3390/s8031595}},
  doi          = {{10.3390/s8031595}},
  volume       = {{8}},