Measurement of blood flow in rat liver with Xenon-133.

Bolmsjö, M. ; Hafström, L. ; Hugander, A. and Persson, B. LU orcid (1983) In International journal of microcirculation, clinical and experimental / sponsored by the European Society for Microcirculation 2(1). p.27-37
Abstract

The blood flow in rat liver was measured with Xe-133. Three techniques for administering the activity to the liver were employed: injection via the portal vein, via the hepatic artery, and directly into the liver parenchyma. Use of intraparenchymal injection of Xe-133 gave 60% higher flow values than by portal or arterial injection techniques. Mean flow index (k1) was for portal injection 0.52, for arterial injection 0.51 and for intraparenchymal injection 0.80. These variations may be explained by the microcirculatory anatomy of the rat liver. The data presented have a high degree of variance between repeated experiments on the same animal. During an experimental procedure, only larger changes in the liver blood flow pattern can be... (More)

The blood flow in rat liver was measured with Xe-133. Three techniques for administering the activity to the liver were employed: injection via the portal vein, via the hepatic artery, and directly into the liver parenchyma. Use of intraparenchymal injection of Xe-133 gave 60% higher flow values than by portal or arterial injection techniques. Mean flow index (k1) was for portal injection 0.52, for arterial injection 0.51 and for intraparenchymal injection 0.80. These variations may be explained by the microcirculatory anatomy of the rat liver. The data presented have a high degree of variance between repeated experiments on the same animal. During an experimental procedure, only larger changes in the liver blood flow pattern can be detected with sufficient accuracy. For this purpose, the method is applicable since repeated and regional studies on the same organ can easily be performed.

(Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Contribution to journal
publication status
published
in
International journal of microcirculation, clinical and experimental / sponsored by the European Society for Microcirculation
volume
2
issue
1
pages
11 pages
publisher
Karger
external identifiers
  • pmid:6678837
  • scopus:0020900379
ISSN
0167-6865
language
English
LU publication?
yes
id
f1aef9bf-902a-4837-bb56-fec7e3b26377
date added to LUP
2020-05-07 21:27:16
date last changed
2024-01-02 10:54:52
@article{f1aef9bf-902a-4837-bb56-fec7e3b26377,
  abstract     = {{<p>The blood flow in rat liver was measured with Xe-133. Three techniques for administering the activity to the liver were employed: injection via the portal vein, via the hepatic artery, and directly into the liver parenchyma. Use of intraparenchymal injection of Xe-133 gave 60% higher flow values than by portal or arterial injection techniques. Mean flow index (k1) was for portal injection 0.52, for arterial injection 0.51 and for intraparenchymal injection 0.80. These variations may be explained by the microcirculatory anatomy of the rat liver. The data presented have a high degree of variance between repeated experiments on the same animal. During an experimental procedure, only larger changes in the liver blood flow pattern can be detected with sufficient accuracy. For this purpose, the method is applicable since repeated and regional studies on the same organ can easily be performed.</p>}},
  author       = {{Bolmsjö, M. and Hafström, L. and Hugander, A. and Persson, B.}},
  issn         = {{0167-6865}},
  language     = {{eng}},
  month        = {{12}},
  number       = {{1}},
  pages        = {{27--37}},
  publisher    = {{Karger}},
  series       = {{International journal of microcirculation, clinical and experimental / sponsored by the European Society for Microcirculation}},
  title        = {{Measurement of blood flow in rat liver with Xenon-133.}},
  volume       = {{2}},
  year         = {{1983}},
}