Computational analysis of an O2separating membrane for a CO2-emission-free power process

Selimovic, Faruk LU ; Sundén, Bengt LU ; Assadi, Mohsen LU and Selimovic, Azra LU (2004) ASME International Mechanical Engineering Congress and Exposition, 2004 375(2). p.9-18
Abstract
The increased demand for clean power in recent years has led to the development of various processes that include different types of CO2 capture. Several options are possible: pre-combustion concepts (fuel de-carbonization and subsequent combustion of H2), post-combustion concepts (tail-end CO2 capture solutions, such as amine scrubbing), and integrated concepts in which combustion is carried out in pure a O2 or oxygen-enriched environment instead of air. The integrated concepts involve the use of oxygen-, hydrogen-, or CO2- separating membranes resulting in exhaust gas containing CO2 and water, from which CO2 can easily be separated. In contrast to traditional oxygen pumps, where a solid oxide electrolyte is sandwiched between two... (More)
The increased demand for clean power in recent years has led to the development of various processes that include different types of CO2 capture. Several options are possible: pre-combustion concepts (fuel de-carbonization and subsequent combustion of H2), post-combustion concepts (tail-end CO2 capture solutions, such as amine scrubbing), and integrated concepts in which combustion is carried out in pure a O2 or oxygen-enriched environment instead of air. The integrated concepts involve the use of oxygen-, hydrogen-, or CO2- separating membranes resulting in exhaust gas containing CO2 and water, from which CO2 can easily be separated. In contrast to traditional oxygen pumps, where a solid oxide electrolyte is sandwiched between two gas-permeable electrodes, a dense, mixed ionic-electronic conducting membrane (MIECM) shows high potential for oxygen separation without external electrodes attached to the oxide surface. Models for oxygen transport through dense membranes have been reported in numerous recent studies. In this study, an equation for oxygen separation has been integrated into a steady-state heat and mass transfer membrane model. Oxygen transfer through a porous supporting layer of membrane is also taken into account. The developed FORTRAN code has been used for numerical investigation and performance analysis of the MIECM and the oxygen transport potential over a range of operating conditions. Preliminary results indicate that a non-uniform temperature distribution, for a given set of oxygen inlet boundary conditions has considerable impact on the oxygen flux and membrane efficiency. Since the implementation of detailed membrane models in heat and mass balance calculations for system studies would result in excessive calculation time, results from this study will be utilized for the generation of correlations describing the oxygen transfer as a function of operating parameters such as temperature and partial pressure. This modeling approach is expected to improve the accuracy of system studies. (Less)
Please use this url to cite or link to this publication:
author
; ; and
organization
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
keywords
Oxygen Transfer Membranes (OTM), Advanced Zero Emission Power Plant (AZEP), High Temperature Heat Exchanger (HTHEX), Mixed Ionic-Electronic Conducting Membrane (MIEC), Oxygen transfer, Gas-permeable electrodes, Emission-free power process, Computational analysis, Monolithic Heat Exchanger
host publication
American Society of Mechanical Engineers, Heat Transfer Division, (Publication) HTD
volume
375
issue
2
pages
9 - 18
publisher
American Society Of Mechanical Engineers (ASME)
conference name
ASME International Mechanical Engineering Congress and Exposition, 2004
conference location
Anaheim, CA, United States
conference dates
2004-11-13 - 2004-11-19
ISSN
0272-5673
language
English
LU publication?
yes
id
fa88bab0-fdd5-43cc-af8f-8f4cb4698a2c (old id 602575)
date added to LUP
2016-04-01 16:39:41
date last changed
2020-06-16 13:55:15
@inproceedings{fa88bab0-fdd5-43cc-af8f-8f4cb4698a2c,
  abstract     = {{The increased demand for clean power in recent years has led to the development of various processes that include different types of CO2 capture. Several options are possible: pre-combustion concepts (fuel de-carbonization and subsequent combustion of H2), post-combustion concepts (tail-end CO2 capture solutions, such as amine scrubbing), and integrated concepts in which combustion is carried out in pure a O2 or oxygen-enriched environment instead of air. The integrated concepts involve the use of oxygen-, hydrogen-, or CO2- separating membranes resulting in exhaust gas containing CO2 and water, from which CO2 can easily be separated. In contrast to traditional oxygen pumps, where a solid oxide electrolyte is sandwiched between two gas-permeable electrodes, a dense, mixed ionic-electronic conducting membrane (MIECM) shows high potential for oxygen separation without external electrodes attached to the oxide surface. Models for oxygen transport through dense membranes have been reported in numerous recent studies. In this study, an equation for oxygen separation has been integrated into a steady-state heat and mass transfer membrane model. Oxygen transfer through a porous supporting layer of membrane is also taken into account. The developed FORTRAN code has been used for numerical investigation and performance analysis of the MIECM and the oxygen transport potential over a range of operating conditions. Preliminary results indicate that a non-uniform temperature distribution, for a given set of oxygen inlet boundary conditions has considerable impact on the oxygen flux and membrane efficiency. Since the implementation of detailed membrane models in heat and mass balance calculations for system studies would result in excessive calculation time, results from this study will be utilized for the generation of correlations describing the oxygen transfer as a function of operating parameters such as temperature and partial pressure. This modeling approach is expected to improve the accuracy of system studies.}},
  author       = {{Selimovic, Faruk and Sundén, Bengt and Assadi, Mohsen and Selimovic, Azra}},
  booktitle    = {{American Society of Mechanical Engineers, Heat Transfer Division, (Publication) HTD}},
  issn         = {{0272-5673}},
  keywords     = {{Oxygen Transfer Membranes (OTM); Advanced Zero Emission Power Plant (AZEP); High Temperature Heat Exchanger (HTHEX); Mixed Ionic-Electronic Conducting Membrane (MIEC); Oxygen transfer; Gas-permeable electrodes; Emission-free power process; Computational analysis; Monolithic Heat Exchanger}},
  language     = {{eng}},
  number       = {{2}},
  pages        = {{9--18}},
  publisher    = {{American Society Of Mechanical Engineers (ASME)}},
  title        = {{Computational analysis of an O<sub>2</sub>separating membrane for a CO<sub>2</sub>-emission-free power process}},
  url          = {{https://lup.lub.lu.se/search/files/4738728/602640.pdf}},
  volume       = {{375}},
  year         = {{2004}},
}