Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Biotechnological treatment of chlorophenol-contaminated water

Zilouei, Hamid LU (2007)
Abstract
Widespread presence of toxic and persistent pollutants in the environment, even at low concentrations, causes risks of adverse effects to human health and the ecosystem. Biological methods for treatment of water streams and removal of persistent pollutants are of great interest due to their simplicity, low cost, and mild operational conditions without harmful by-products. The purpose of this research was to improve high-performance bioprocesses for treatment of water streams contaminated with toxic organic pollutants. Chlorophenols were chosen as model toxic organic pollutants to degrade.



Biological treatment processes are usually inhibited by the presence of toxic pollutants. Photolysis pretreatment was successfully... (More)
Widespread presence of toxic and persistent pollutants in the environment, even at low concentrations, causes risks of adverse effects to human health and the ecosystem. Biological methods for treatment of water streams and removal of persistent pollutants are of great interest due to their simplicity, low cost, and mild operational conditions without harmful by-products. The purpose of this research was to improve high-performance bioprocesses for treatment of water streams contaminated with toxic organic pollutants. Chlorophenols were chosen as model toxic organic pollutants to degrade.



Biological treatment processes are usually inhibited by the presence of toxic pollutants. Photolysis pretreatment was successfully used to detoxify the chlorophenols-contaminated water followed by mineralization in biological step, which was not observed using individual biological treatment. Two-liquid phase partitioning bioreactor was also used for mineralization of pentachlorophenol, at high concentrations, without accumulation of metabolites. Biphasic system was optimized by investigating the influence of type of the solvent, phase ratio, agitation speed, and substrate concentration. Integrated physicochemical-biological processes presented high potential for treatment of toxic pollutants by providing the potential to prevent accumulation of hazardous by-products in chemical treatment, reduce the toxicity of effluent for biological processes, and control the delivery of pollutants to the microorganisms.



Fixed-biofilm reactors were used for degradation of chlorophenols under different operational conditions including suboptimal environment. These reactors were studied under different organic and hydraulic loading rates, temperatures, and substrate feedings. High removal efficiencies were obtained even at low temperatures down to 4?C. However, different patterns and removal efficiencies were observed for different chlorophenols fed to the reactors. The performance of fixed-biofilm reactors was limited neither by the bacterial activity nor by the inhibition effect of substrate at high loading rates, but by the limited solubility of oxygen in water to provide dissolved oxygen for the microorganisms.



An essential issue for improvement of biological processes is in situ monitoring of the hydrodynamic and biological parameters in relating to operational conditions and process efficiency. The biological treatment processes were investigated in situ by monitoring the bacterial community profile using fluorescence in situ hybridization technique and the concentration of toxic pollutants using a cell-based biosensor. Biofilms from different reactors were dominated by ?- and then ?-proteobacteria. Bacterial community of biofilm was not influenced by organic loading rate. However, reduction of the working temperature caused significant increase in the population of ?-proteobacteria and Pseudomonas based on total community. Two bacteria were isolated from biofilms and identified as Ralstonia basilensis and Alcaligenes sp. able to degrade 50 mg chlorophenol l-1 under a wide range of temperature 5-30?C. Beside to this, a cell-based biosensor was developed able to detect and monitor the concentration of dichlorophenol. The performance of biosensor was improved by integrating within a flow injection system for continuous analysis of target pollutant. (Less)
Please use this url to cite or link to this publication:
author
supervisor
opponent
  • Prof. Dr. Margesin, Rosa, Institute of Microbiology, Leopold-Franzens University of Innsbruck, Austria
organization
publishing date
type
Thesis
publication status
published
subject
keywords
Biotechnology, Bioteknik, kontroll av utsläpp, Miljöteknik, pollution control, Environmental technology, Cell-based biosensor, Fluorescence in situ hybridization, Bacterial community, Two-liquid phase partitioning bioreactor, Photolysis pretreatment, Biomonitoring, Fixed-biofilm reactors, Toxic organic pollutant, Biodegradation
pages
102 pages
publisher
Biotechnology, Lund University
defense location
Lecture hall B, Center for Chemistry and Chemical Engineering, Getingevägen 60, Lunds Tekniska Högskola
defense date
2007-02-20 10:30:00
external identifiers
  • other:ISRN: LUTKDH/TKBT--07/1106--SE
ISBN
978-91-89627-53-6
language
English
LU publication?
yes
id
faa964c1-effb-4762-8ece-8ad86620f154 (old id 548024)
date added to LUP
2016-04-04 10:26:35
date last changed
2018-11-21 20:58:46
@phdthesis{faa964c1-effb-4762-8ece-8ad86620f154,
  abstract     = {{Widespread presence of toxic and persistent pollutants in the environment, even at low concentrations, causes risks of adverse effects to human health and the ecosystem. Biological methods for treatment of water streams and removal of persistent pollutants are of great interest due to their simplicity, low cost, and mild operational conditions without harmful by-products. The purpose of this research was to improve high-performance bioprocesses for treatment of water streams contaminated with toxic organic pollutants. Chlorophenols were chosen as model toxic organic pollutants to degrade.<br/><br>
<br/><br>
Biological treatment processes are usually inhibited by the presence of toxic pollutants. Photolysis pretreatment was successfully used to detoxify the chlorophenols-contaminated water followed by mineralization in biological step, which was not observed using individual biological treatment. Two-liquid phase partitioning bioreactor was also used for mineralization of pentachlorophenol, at high concentrations, without accumulation of metabolites. Biphasic system was optimized by investigating the influence of type of the solvent, phase ratio, agitation speed, and substrate concentration. Integrated physicochemical-biological processes presented high potential for treatment of toxic pollutants by providing the potential to prevent accumulation of hazardous by-products in chemical treatment, reduce the toxicity of effluent for biological processes, and control the delivery of pollutants to the microorganisms.<br/><br>
<br/><br>
Fixed-biofilm reactors were used for degradation of chlorophenols under different operational conditions including suboptimal environment. These reactors were studied under different organic and hydraulic loading rates, temperatures, and substrate feedings. High removal efficiencies were obtained even at low temperatures down to 4?C. However, different patterns and removal efficiencies were observed for different chlorophenols fed to the reactors. The performance of fixed-biofilm reactors was limited neither by the bacterial activity nor by the inhibition effect of substrate at high loading rates, but by the limited solubility of oxygen in water to provide dissolved oxygen for the microorganisms.<br/><br>
<br/><br>
An essential issue for improvement of biological processes is in situ monitoring of the hydrodynamic and biological parameters in relating to operational conditions and process efficiency. The biological treatment processes were investigated in situ by monitoring the bacterial community profile using fluorescence in situ hybridization technique and the concentration of toxic pollutants using a cell-based biosensor. Biofilms from different reactors were dominated by ?- and then ?-proteobacteria. Bacterial community of biofilm was not influenced by organic loading rate. However, reduction of the working temperature caused significant increase in the population of ?-proteobacteria and Pseudomonas based on total community. Two bacteria were isolated from biofilms and identified as Ralstonia basilensis and Alcaligenes sp. able to degrade 50 mg chlorophenol l-1 under a wide range of temperature 5-30?C. Beside to this, a cell-based biosensor was developed able to detect and monitor the concentration of dichlorophenol. The performance of biosensor was improved by integrating within a flow injection system for continuous analysis of target pollutant.}},
  author       = {{Zilouei, Hamid}},
  isbn         = {{978-91-89627-53-6}},
  keywords     = {{Biotechnology; Bioteknik; kontroll av utsläpp; Miljöteknik; pollution control; Environmental technology; Cell-based biosensor; Fluorescence in situ hybridization; Bacterial community; Two-liquid phase partitioning bioreactor; Photolysis pretreatment; Biomonitoring; Fixed-biofilm reactors; Toxic organic pollutant; Biodegradation}},
  language     = {{eng}},
  publisher    = {{Biotechnology, Lund University}},
  school       = {{Lund University}},
  title        = {{Biotechnological treatment of chlorophenol-contaminated water}},
  year         = {{2007}},
}