Design, development, construction and installation of a ceramic chamber for a pulsed kicker at LNLS storage ring

Ferreira, M. J. LU ; Bagnato, O. R. ; Arroyo, F. C. ; Ferraz, O. R. ; Francisco, F. R. ; Gobbi, A. L. ; Seraphim, R. M. and Silva, M. B. (2005) Particle Accelerator Conference, PAC 2005 In Proceedings of the IEEE Particle Accelerator Conference 2005. p.689-691
Abstract

Following the upgrade of the LNLS injector system with the addition of a 500 MeV booster synchrotron, the storage ring in vacuum ferrite injection kicker magnets started to show overheating due the interaction with high frequency electromagnetic fields induced by the electron beam in large currents. In this paper, we describe the design of a new ceramic chamber for the kickers, which minimize this effect by decreasing the coupling impedance of the kickers and their interaction with the electron beam.

Please use this url to cite or link to this publication:
author
; ; ; ; ; ; and
publishing date
type
Chapter in Book/Report/Conference proceeding
publication status
published
subject
host publication
Proceedings of the Particle Accelerator Conference, PAC 2005
series title
Proceedings of the IEEE Particle Accelerator Conference
volume
2005
pages
3 pages
publisher
IEEE Press
conference name
Particle Accelerator Conference, PAC 2005
conference location
Knoxville, TN, United States
conference dates
2005-05-16 - 2005-05-20
external identifiers
  • scopus:33847092071
ISBN
0780388593
9780780388598
DOI
10.1109/PAC.2005.1590529
language
English
LU publication?
no
id
fe301b53-7943-4fa4-b822-9ced1f290c65
date added to LUP
2025-01-26 11:47:27
date last changed
2025-04-04 14:24:27
@inproceedings{fe301b53-7943-4fa4-b822-9ced1f290c65,
  abstract     = {{<p>Following the upgrade of the LNLS injector system with the addition of a 500 MeV booster synchrotron, the storage ring in vacuum ferrite injection kicker magnets started to show overheating due the interaction with high frequency electromagnetic fields induced by the electron beam in large currents. In this paper, we describe the design of a new ceramic chamber for the kickers, which minimize this effect by decreasing the coupling impedance of the kickers and their interaction with the electron beam.</p>}},
  author       = {{Ferreira, M. J. and Bagnato, O. R. and Arroyo, F. C. and Ferraz, O. R. and Francisco, F. R. and Gobbi, A. L. and Seraphim, R. M. and Silva, M. B.}},
  booktitle    = {{Proceedings of the Particle Accelerator Conference, PAC 2005}},
  isbn         = {{0780388593}},
  language     = {{eng}},
  pages        = {{689--691}},
  publisher    = {{IEEE Press}},
  series       = {{Proceedings of the IEEE Particle Accelerator Conference}},
  title        = {{Design, development, construction and installation of a ceramic chamber for a pulsed kicker at LNLS storage ring}},
  url          = {{http://dx.doi.org/10.1109/PAC.2005.1590529}},
  doi          = {{10.1109/PAC.2005.1590529}},
  volume       = {{2005}},
  year         = {{2005}},
}