Evaluating the Possibility and Beneficiality of Continuous Control of a Circulation Pump in an Air-to-Water Heat Pump
(2026)Department of Automatic Control
- Abstract
- This thesis investigates the possibility and potential benefit of switching from an on/off control strategy to a continuous PWM based control. The control is applied on a circulation pump driven by a BLDC motor in SoletAer AB’s air-to-water heat pump, which today uses an on/off control strategy. The current control strategy is investigated and a PWM based control is implemented using a Raspberry Pi.
The project aims to compare the efficiency of the two control strategies and to minimize the sound effect produced when the pump switches off, which appears every 1.1 to 2.9 seconds in the current implementation. Based on measurements of e.g. flow rate and voltage over the motor, the response characteristics of the pump are presented, and the... (More) - This thesis investigates the possibility and potential benefit of switching from an on/off control strategy to a continuous PWM based control. The control is applied on a circulation pump driven by a BLDC motor in SoletAer AB’s air-to-water heat pump, which today uses an on/off control strategy. The current control strategy is investigated and a PWM based control is implemented using a Raspberry Pi.
The project aims to compare the efficiency of the two control strategies and to minimize the sound effect produced when the pump switches off, which appears every 1.1 to 2.9 seconds in the current implementation. Based on measurements of e.g. flow rate and voltage over the motor, the response characteristics of the pump are presented, and the effects of hysteresis, friction and saturation in the motor are visualized and discussed.
The output of the current control is recreated using the PWMbased control to mimic the result while having the control continuous rather than discrete. The efficiency of the two cases, respectively, is compared to evaluate whether changing control approach is beneficial. The comparison results in an efficiency increase of 34.4%.
It is concluded that switching to continuous control is possible and beneficial. The sound effect is believed to be minimized in intensity using this approach, but cannot be recreated in the test setup. It is, however, reduced in periodicity as the continuous control does not require the pump to turn completely off to the same extent. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/student-papers/record/9251221
- author
- Astgård, Alva
- supervisor
- organization
- year
- 2026
- type
- H3 - Professional qualifications (4 Years - )
- subject
- report number
- TFRT-6322
- other publication id
- 0280-5316
- language
- English
- id
- 9251221
- date added to LUP
- 2026-09-18 11:39:51
- date last changed
- 2026-09-18 11:39:51
@misc{9251221,
abstract = {{This thesis investigates the possibility and potential benefit of switching from an on/off control strategy to a continuous PWM based control. The control is applied on a circulation pump driven by a BLDC motor in SoletAer AB’s air-to-water heat pump, which today uses an on/off control strategy. The current control strategy is investigated and a PWM based control is implemented using a Raspberry Pi.
The project aims to compare the efficiency of the two control strategies and to minimize the sound effect produced when the pump switches off, which appears every 1.1 to 2.9 seconds in the current implementation. Based on measurements of e.g. flow rate and voltage over the motor, the response characteristics of the pump are presented, and the effects of hysteresis, friction and saturation in the motor are visualized and discussed.
The output of the current control is recreated using the PWMbased control to mimic the result while having the control continuous rather than discrete. The efficiency of the two cases, respectively, is compared to evaluate whether changing control approach is beneficial. The comparison results in an efficiency increase of 34.4%.
It is concluded that switching to continuous control is possible and beneficial. The sound effect is believed to be minimized in intensity using this approach, but cannot be recreated in the test setup. It is, however, reduced in periodicity as the continuous control does not require the pump to turn completely off to the same extent.}},
author = {{Astgård, Alva}},
language = {{eng}},
note = {{Student Paper}},
title = {{Evaluating the Possibility and Beneficiality of Continuous Control of a Circulation Pump in an Air-to-Water Heat Pump}},
year = {{2026}},
}