BIPV-based Microgrids for Residential Energy Resilience: A Cross-Climate BIM-to-BEM Assessment
(2026) MVKM05 20261Department of Energy Sciences
- Abstract
- Residential buildings that deploy photovoltaics do not always utilise the total amount of energy they produce. This is because there is a mismatch between PV production and the requirements of the building. This mismatch can sometimes be addressed by deploying a battery storage system. But once storage capacity is exceeded, any remaining surplus is exported to the grid rather than used on site. This study investigates a method to better utilise the surplus locally before any grid export. This is done by connecting a small cluster of residential and commercial buildings to exchange electricity directly with one another. This approach is referred to as peer-to-peer (P2P) energy exchange, wherein the surplus from one building is directed to a... (More)
- Residential buildings that deploy photovoltaics do not always utilise the total amount of energy they produce. This is because there is a mismatch between PV production and the requirements of the building. This mismatch can sometimes be addressed by deploying a battery storage system. But once storage capacity is exceeded, any remaining surplus is exported to the grid rather than used on site. This study investigates a method to better utilise the surplus locally before any grid export. This is done by connecting a small cluster of residential and commercial buildings to exchange electricity directly with one another. This approach is referred to as peer-to-peer (P2P) energy exchange, wherein the surplus from one building is directed to a neighbouring building with unmet demand. The exchanged energy, when later returned to the originating building during its own deficit hours, counts as self-consumed rather than grid-imported, raising that building's self-consumption ratio (SCR).
This study assesses P2P microgrid design strategies across two contrasting climates: Malmö, a high-latitude location with low irradiance, and Dubai, a high-irradiance location with cooling-dominated demand. Six building types, including four residential typologies (Trad-Villa, Mod-Villa, MHP, and MTA) and two commercial typologies (a small retail Shoebox and a larger commercial ARK), are modelled using the BIM-to-BEM framework and simulated in IDA ICE. The hourly load profiles derived from the BEM simulation are used to simulate 104 different microgrid combinations, each assessed for the extent to which P2P exchange improves the residential SCR.
It is found that P2P exchange improved residential SCR in every configuration tested, without any exception. The magnitude of improvement depends on the microgrid composition. Scaling commercial units consistently in a microgrid combination produced the strongest residential SCR gains, ahead of residential scaling. The caveat, however, is the choice of commercial partner. The determining factor was not whether a commercial building was retail or office by function, but how low its demand sat relative to its own production. Low-demand, high-surplus buildings like the Shoebox consistently outperformed demand-heavy buildings like the ARK. Among the residential typologies, the Trad-Villa benefited most from aggregation by a clear margin, gaining close to 8 percentage points in Malmö and nearly 14 in Dubai. Taken together, these findings point to a practical design principle: P2P aggregation delivers its biggest gains when residential buildings carrying genuine unmet demand are paired with commercial partners that have genuine surplus to give during those unmet hours. Once that pairing is identified, the grid’s production-to-demand ratio (PDR) becomes a useful design reference for sizing the grid itself. This settles into a fairly tight band in both climates, roughly 0.30 to 0.34 in Malmö and roughly 0.14 to 0.15 in Dubai. (Less) - Popular Abstract
- Solar panels often make more power than a home needs at noon, and too little at night. This study asked a simple question: what if the house next door could just borrow the leftovers?
Picture a house with solar panels. Around midday, when the sun is strongest, the house barely uses any electricity, everyone is out, and the panels are quietly making far more power than anyone inside needs. That extra power usually gets sent off to the public grid, often for very little in return. Then evening comes, the family is home, the kettle goes on, and the house has to buy electricity back from the grid because its own panels have gone quiet for the day.
Now picture that same house sitting next to a small shop. The shop is busiest exactly when... (More) - Solar panels often make more power than a home needs at noon, and too little at night. This study asked a simple question: what if the house next door could just borrow the leftovers?
Picture a house with solar panels. Around midday, when the sun is strongest, the house barely uses any electricity, everyone is out, and the panels are quietly making far more power than anyone inside needs. That extra power usually gets sent off to the public grid, often for very little in return. Then evening comes, the family is home, the kettle goes on, and the house has to buy electricity back from the grid because its own panels have gone quiet for the day.
Now picture that same house sitting next to a small shop. The shop is busiest exactly when the house is emptiest, so it has plenty of appetite for that midday solar surplus. Instead of shipping the extra power off to the grid, the house could hand it straight to its neighbour. Multiply that by a whole street of houses and shops, and you have a microgrid, a small cluster of buildings trading solar power among themselves before any of it touches the public grid.
This project tested exactly that idea, using computer models of four house types and two kinds of commercial buildings, a small shop and a large office, in two very different climates: sunny, scorching Dubai and cold, cloudy Malmo. The results were clear. Every single combination of buildings tested got more use out of its own solar power locally once trading was switched on, with no exceptions.
The gains were not evenly spread, though, and this is where it gets interesting. Houses that already produced roughly as much power as they needed, but at the wrong times of day, benefited the most from having a neighbour to trade with. One house type in particular saw its self-sufficiency jump by nearly 8 percentage points in Malmo and by almost 14 percentage points in Dubai simply by pairing with the right commercial neighbour. The small shop turned out to be a far better partner than the large office, because it had real surplus appetite to offer, while the office mostly kept its own solar power for itself.
Climate mattered too, but less for which pairing worked best and more for how big the payoff was. Dubai, with its intense year-round sun, consistently delivered bigger gains than Malmo. The study also points to a practical target for anyone sizing solar panels for a cluster of buildings like this: in Dubai, the local panels should be sized to cover only around 15% of the cluster's total electricity use, while in Malmo, with its weaker winter sun, that number is closer to 30%. Go bigger than that and the extra panels mostly just export power nobody nearby needs.
The takeaway is simple. Solar panels do not need a battery in every basement to be useful around the clock, sometimes a good neighbour does the job just as well. (Less)
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/student-papers/record/9251450
- author
- Zaman, Adnan LU
- supervisor
-
- Pieter de Wilde LU
- Pouria Elahi LU
- organization
- course
- MVKM05 20261
- year
- 2026
- type
- H2 - Master's Degree (Two Years)
- subject
- keywords
- Building-Integrated Photovoltaics (BIPV), Microgrid Aggregation, Peer-to-Peer Energy Exchange, BIM-to-BEM, Climate-Specific Microgrid Design
- report number
- LUTMDN/TMHP-26/5713-SE
- ISSN
- 0282-1990
- language
- English
- id
- 9251450
- date added to LUP
- 2026-09-23 12:23:27
- date last changed
- 2026-09-23 12:23:27
@misc{9251450,
abstract = {{Residential buildings that deploy photovoltaics do not always utilise the total amount of energy they produce. This is because there is a mismatch between PV production and the requirements of the building. This mismatch can sometimes be addressed by deploying a battery storage system. But once storage capacity is exceeded, any remaining surplus is exported to the grid rather than used on site. This study investigates a method to better utilise the surplus locally before any grid export. This is done by connecting a small cluster of residential and commercial buildings to exchange electricity directly with one another. This approach is referred to as peer-to-peer (P2P) energy exchange, wherein the surplus from one building is directed to a neighbouring building with unmet demand. The exchanged energy, when later returned to the originating building during its own deficit hours, counts as self-consumed rather than grid-imported, raising that building's self-consumption ratio (SCR).
This study assesses P2P microgrid design strategies across two contrasting climates: Malmö, a high-latitude location with low irradiance, and Dubai, a high-irradiance location with cooling-dominated demand. Six building types, including four residential typologies (Trad-Villa, Mod-Villa, MHP, and MTA) and two commercial typologies (a small retail Shoebox and a larger commercial ARK), are modelled using the BIM-to-BEM framework and simulated in IDA ICE. The hourly load profiles derived from the BEM simulation are used to simulate 104 different microgrid combinations, each assessed for the extent to which P2P exchange improves the residential SCR.
It is found that P2P exchange improved residential SCR in every configuration tested, without any exception. The magnitude of improvement depends on the microgrid composition. Scaling commercial units consistently in a microgrid combination produced the strongest residential SCR gains, ahead of residential scaling. The caveat, however, is the choice of commercial partner. The determining factor was not whether a commercial building was retail or office by function, but how low its demand sat relative to its own production. Low-demand, high-surplus buildings like the Shoebox consistently outperformed demand-heavy buildings like the ARK. Among the residential typologies, the Trad-Villa benefited most from aggregation by a clear margin, gaining close to 8 percentage points in Malmö and nearly 14 in Dubai. Taken together, these findings point to a practical design principle: P2P aggregation delivers its biggest gains when residential buildings carrying genuine unmet demand are paired with commercial partners that have genuine surplus to give during those unmet hours. Once that pairing is identified, the grid’s production-to-demand ratio (PDR) becomes a useful design reference for sizing the grid itself. This settles into a fairly tight band in both climates, roughly 0.30 to 0.34 in Malmö and roughly 0.14 to 0.15 in Dubai.}},
author = {{Zaman, Adnan}},
issn = {{0282-1990}},
language = {{eng}},
note = {{Student Paper}},
title = {{BIPV-based Microgrids for Residential Energy Resilience: A Cross-Climate BIM-to-BEM Assessment}},
year = {{2026}},
}