Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Pulmonary embolism: detection with MR perfusion imaging of lung--a feasibility study

Amundsen, Tore ; Kvaerness, Jörn ; Jones, Richard A ; Waage, Anders ; Bjermer, Leif LU ; Nilsen, Gunnar and Haraldseth, Olav (1997) In Radiology 203(1). p.181-185
Abstract
PURPOSE: To evaluate the feasibility of magnetic resonance (MR) perfusion imaging in the human lung to help detect perfusion defects distal to suspected pulmonary embolism. MATERIALS AND METHODS: Seven patients suspected of having pulmonary embolism first underwent ventilation-perfusion lung scintigraphy followed by MR perfusion imaging with rapid acquisition of two sets of dynamic images in the coronal and transaxial planes. A bolus of 0.05 mmol per kilogram of body weight gadopentetate dimeglumine or gadodiamide was administered. Single images obtained in each section that showed peak signal intensity from the first passage of contrast material were evaluated visually. An analysis of change in signal intensity over time was performed... (More)
PURPOSE: To evaluate the feasibility of magnetic resonance (MR) perfusion imaging in the human lung to help detect perfusion defects distal to suspected pulmonary embolism. MATERIALS AND METHODS: Seven patients suspected of having pulmonary embolism first underwent ventilation-perfusion lung scintigraphy followed by MR perfusion imaging with rapid acquisition of two sets of dynamic images in the coronal and transaxial planes. A bolus of 0.05 mmol per kilogram of body weight gadopentetate dimeglumine or gadodiamide was administered. Single images obtained in each section that showed peak signal intensity from the first passage of contrast material were evaluated visually. An analysis of change in signal intensity over time was performed both on a pixel-by-pixel basis and in selected regions of interest. RESULTS: In the seven patients, a total of 18 regions of lung tissue with perfusion defects were shown on the ventilation-perfusion scans. In 16 of these regions, MR perfusion images showed a reduced peak signal intensity during first passage of the contrast agent. Perfusion defects could be detected in both the coronal and the transaxial planes on MR perfusion images. CONCLUSION: MR perfusion imaging was feasible for detection of perfusion defects distal to a pulmonary embolism. (Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; and
publishing date
type
Contribution to journal
publication status
published
subject
in
Radiology
volume
203
issue
1
pages
181 - 185
publisher
Radiological Society of North America
external identifiers
  • pmid:9122390
  • scopus:0030934861
ISSN
1527-1315
language
English
LU publication?
no
id
b0bae995-7c6f-484e-a1e4-76fa3471a9ba (old id 1111419)
alternative location
http://radiology.rsnajnls.org/cgi/reprint/203/1/181
date added to LUP
2016-04-01 15:33:55
date last changed
2022-01-28 05:59:58
@article{b0bae995-7c6f-484e-a1e4-76fa3471a9ba,
  abstract     = {{PURPOSE: To evaluate the feasibility of magnetic resonance (MR) perfusion imaging in the human lung to help detect perfusion defects distal to suspected pulmonary embolism. MATERIALS AND METHODS: Seven patients suspected of having pulmonary embolism first underwent ventilation-perfusion lung scintigraphy followed by MR perfusion imaging with rapid acquisition of two sets of dynamic images in the coronal and transaxial planes. A bolus of 0.05 mmol per kilogram of body weight gadopentetate dimeglumine or gadodiamide was administered. Single images obtained in each section that showed peak signal intensity from the first passage of contrast material were evaluated visually. An analysis of change in signal intensity over time was performed both on a pixel-by-pixel basis and in selected regions of interest. RESULTS: In the seven patients, a total of 18 regions of lung tissue with perfusion defects were shown on the ventilation-perfusion scans. In 16 of these regions, MR perfusion images showed a reduced peak signal intensity during first passage of the contrast agent. Perfusion defects could be detected in both the coronal and the transaxial planes on MR perfusion images. CONCLUSION: MR perfusion imaging was feasible for detection of perfusion defects distal to a pulmonary embolism.}},
  author       = {{Amundsen, Tore and Kvaerness, Jörn and Jones, Richard A and Waage, Anders and Bjermer, Leif and Nilsen, Gunnar and Haraldseth, Olav}},
  issn         = {{1527-1315}},
  language     = {{eng}},
  number       = {{1}},
  pages        = {{181--185}},
  publisher    = {{Radiological Society of North America}},
  series       = {{Radiology}},
  title        = {{Pulmonary embolism: detection with MR perfusion imaging of lung--a feasibility study}},
  url          = {{http://radiology.rsnajnls.org/cgi/reprint/203/1/181}},
  volume       = {{203}},
  year         = {{1997}},
}