Nonlinear Finite Element Analysis of Pull-Out Test

Ottosen, Niels Saabye LU (1981) In Journal of the Structural Division, ASCE 107(4). p.591-603
Abstract
A specific pull-out test used to determine in-situ concrete compressive strength is analyzed. This test consists of a steel disc that is extracted from the structure. The finite element analysis considers cracking as well as strain hardening and softening in the pre- and post-failure region, respectively. The aim is to attain a clear insight into structural behavior. Special attention is given to the failure mode. Severe cracking occurs and the stress distribution is very inhomogeneous. However, large compressive forces run from the disc in a rather narrow band towards the support and this constitutes the load-carrying mechanism. The failure is caused by the crushing of the concrete in this region, and not by cracking.
Please use this url to cite or link to this publication:
author
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Journal of the Structural Division, ASCE
volume
107
issue
4
pages
591 - 603
publisher
American Society of Civil Engineers (ASCE)
external identifiers
  • scopus:0019552232
language
English
LU publication?
yes
id
51ef0a48-ed3f-4799-b0ca-407666ce590c (old id 1370238)
alternative location
http://www.asce.org/
date added to LUP
2016-04-04 11:50:44
date last changed
2021-10-10 03:43:08
@article{51ef0a48-ed3f-4799-b0ca-407666ce590c,
  abstract     = {{A specific pull-out test used to determine in-situ concrete compressive strength is analyzed. This test consists of a steel disc that is extracted from the structure. The finite element analysis considers cracking as well as strain hardening and softening in the pre- and post-failure region, respectively. The aim is to attain a clear insight into structural behavior. Special attention is given to the failure mode. Severe cracking occurs and the stress distribution is very inhomogeneous. However, large compressive forces run from the disc in a rather narrow band towards the support and this constitutes the load-carrying mechanism. The failure is caused by the crushing of the concrete in this region, and not by cracking.}},
  author       = {{Ottosen, Niels Saabye}},
  language     = {{eng}},
  number       = {{4}},
  pages        = {{591--603}},
  publisher    = {{American Society of Civil Engineers (ASCE)}},
  series       = {{Journal of the Structural Division, ASCE}},
  title        = {{Nonlinear Finite Element Analysis of Pull-Out Test}},
  url          = {{http://www.asce.org/}},
  volume       = {{107}},
  year         = {{1981}},
}