Suture-Tool : A Mechanical Needle Driver for Standardized Wound Closure

Börner, Gabriel LU and Montgomery, Agneta LU (2020) In World Journal of Surgery 44(1). p.95-99
Abstract

Introduction: A laparotomy is commonly required to gain abdominal access. A safe standardized access and closure technique is warranted to minimize abdominal wall complications like wound infections, burst abdomen and incisional hernias. Stitches are recommended to be small and placed tightly, obtaining a suture length-to-incision length (SL/WL) ratio of ≥ 4:1. This can be time-consuming and difficult to achieve especially following long trying surgical procedures. The aim was to develop and evaluate a new mechanical suture device for standardized wound closure. Methods: A mechanical suture device (Suture-tool) was developed in collaboration between a medical technology engineer team with the aim to achieve a standardized suture line of... (More)

Introduction: A laparotomy is commonly required to gain abdominal access. A safe standardized access and closure technique is warranted to minimize abdominal wall complications like wound infections, burst abdomen and incisional hernias. Stitches are recommended to be small and placed tightly, obtaining a suture length-to-incision length (SL/WL) ratio of ≥ 4:1. This can be time-consuming and difficult to achieve especially following long trying surgical procedures. The aim was to develop and evaluate a new mechanical suture device for standardized wound closure. Methods: A mechanical suture device (Suture-tool) was developed in collaboration between a medical technology engineer team with the aim to achieve a standardized suture line of high quality that could be performed speedy and safe. Ten surgeons closed an incision in an animal tissue model after a standardized introduction of the instrument comparing the device to conventional needle driver suturing (NDS) using the 4:1 technique. Outcome measures were SL/WL ratio, number of stitches and suture time. Results: In total, 80 suture lines were evaluated. SL/WL ratio of ≥ 4 was achieved in 95% using the Suture-tool and 30% using NDS (p < 0,001). Number of stitches was similar. Suture time was 30% shorter using the Suture-tool compared to NDS (2 min 54 s vs. 4 min 5 s; p < 0.001). Conclusions: The mechanical needle driver seems to be a promising device to perform a speedy standardized high-quality suture line for fascial closure.

(Less)
Please use this url to cite or link to this publication:
author
and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
World Journal of Surgery
volume
44
issue
1
pages
5 pages
publisher
Springer
external identifiers
  • pmid:31549201
  • scopus:85074392526
ISSN
0364-2313
DOI
10.1007/s00268-019-05179-5
language
English
LU publication?
yes
id
140ed789-f4d8-4d02-9cd2-bf1c2471e102
date added to LUP
2019-11-21 13:56:25
date last changed
2024-04-02 21:53:02
@article{140ed789-f4d8-4d02-9cd2-bf1c2471e102,
  abstract     = {{<p>Introduction: A laparotomy is commonly required to gain abdominal access. A safe standardized access and closure technique is warranted to minimize abdominal wall complications like wound infections, burst abdomen and incisional hernias. Stitches are recommended to be small and placed tightly, obtaining a suture length-to-incision length (SL/WL) ratio of ≥ 4:1. This can be time-consuming and difficult to achieve especially following long trying surgical procedures. The aim was to develop and evaluate a new mechanical suture device for standardized wound closure. Methods: A mechanical suture device (Suture-tool) was developed in collaboration between a medical technology engineer team with the aim to achieve a standardized suture line of high quality that could be performed speedy and safe. Ten surgeons closed an incision in an animal tissue model after a standardized introduction of the instrument comparing the device to conventional needle driver suturing (NDS) using the 4:1 technique. Outcome measures were SL/WL ratio, number of stitches and suture time. Results: In total, 80 suture lines were evaluated. SL/WL ratio of ≥ 4 was achieved in 95% using the Suture-tool and 30% using NDS (p &lt; 0,001). Number of stitches was similar. Suture time was 30% shorter using the Suture-tool compared to NDS (2 min 54 s vs. 4 min 5 s; p &lt; 0.001). Conclusions: The mechanical needle driver seems to be a promising device to perform a speedy standardized high-quality suture line for fascial closure.</p>}},
  author       = {{Börner, Gabriel and Montgomery, Agneta}},
  issn         = {{0364-2313}},
  language     = {{eng}},
  number       = {{1}},
  pages        = {{95--99}},
  publisher    = {{Springer}},
  series       = {{World Journal of Surgery}},
  title        = {{Suture-Tool : A Mechanical Needle Driver for Standardized Wound Closure}},
  url          = {{http://dx.doi.org/10.1007/s00268-019-05179-5}},
  doi          = {{10.1007/s00268-019-05179-5}},
  volume       = {{44}},
  year         = {{2020}},
}