Skip to main content

Lund University Publications

LUND UNIVERSITY LIBRARIES

Endometrial Thickness Measurement for Detecting Endometrial Cancer in Women With Postmenopausal Bleeding A Systematic Review and Meta-Analysis

Timmermans, Anne ; Opmeer, Brent C. ; Khan, Khalid S. ; Bachmann, Lucas M. ; Epstein, Elisabeth LU ; Clark, T. Justin ; Gupta, Janesh K. ; Bakour, Shagaf H. ; van den Bosch, Thierry and van Doorn, Helena C. , et al. (2010) In Obstetrics and Gynecology 116(1). p.160-167
Abstract
OBJECTIVE: To estimate the accuracy of endometrial thickness measurement in the detection of endometrial cancer among women with postmenopausal bleeding with individual patient data using different meta-analytic strategies. DATA SOURCES: Original data sets of studies detected after reviewing the included studies of three previous reviews on this subject. An additional literature search of published articles using MEDLINE databases was preformed from January 2000 to December 2006 to identify articles reporting on endometrial carcinoma and sonographic endometrial thickness measurement in women with postmenopausal bleeding. METHODS OF STUDY SELECTION: We identified 90 studies reporting on endometrial thickness measurements and endometrial... (More)
OBJECTIVE: To estimate the accuracy of endometrial thickness measurement in the detection of endometrial cancer among women with postmenopausal bleeding with individual patient data using different meta-analytic strategies. DATA SOURCES: Original data sets of studies detected after reviewing the included studies of three previous reviews on this subject. An additional literature search of published articles using MEDLINE databases was preformed from January 2000 to December 2006 to identify articles reporting on endometrial carcinoma and sonographic endometrial thickness measurement in women with postmenopausal bleeding. METHODS OF STUDY SELECTION: We identified 90 studies reporting on endometrial thickness measurements and endometrial carcinoma in women with postmenopausal bleeding. TABULATION, INTEGRATION, AND RESULTS: We contacted 79 primary investigators to obtain the individual patient data of their reported studies, of which 13 could provide data. Data on 2,896 patients, of which 259 had carcinoma, were included. Several approaches were used in the analyses of the acquired data. First, we performed receiver operator characteristics (ROC) analysis per study, resulting in a summary area under the ROC curve (AUC) calculated as a weighted mean of AUCs from original studies. Second, individual patient data were pooled and analyzed with ROC analyses irrespective of study with standardization of distributional differences across studies using multiples of the median and by random effects logistic regression. Finally, we also used a two-stage procedure, calculating sensitivities and specificities for each study and using the bivariate random effects model to estimate summary estimates for diagnostic accuracy. This resulted in rather comparable ROC curves with AUCs varying between 0.82 and 0.84 and summary estimates for sensitivity and specificity located along these curves. These curves indicated a lower AUC than previously reported meta-analyses using conventional techniques. CONCLUSION: Previous meta-analyses on endometrial thickness measurement probably have overestimated its diagnostic accuracy in the detection of endometrial carcinoma. We advise the use of cutoff level of 3 mm for exclusion of endometrial carcinoma in women with postmenopausal bleeding. (Obstet Gynecol 2010;116:160-7) (Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; ; and , et al. (More)
; ; ; ; ; ; ; ; ; ; ; ; ; ; and (Less)
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Obstetrics and Gynecology
volume
116
issue
1
pages
160 - 167
publisher
Lippincott Williams & Wilkins
external identifiers
  • wos:000278998600025
  • scopus:77954060495
  • pmid:20567183
ISSN
1873-233X
DOI
10.1097/AOG.0b013e3181e3e7e8
language
English
LU publication?
yes
id
4fcf1a97-04a2-4b5b-a581-6350ec2f2da2 (old id 1629962)
date added to LUP
2016-04-01 13:23:37
date last changed
2022-04-14 00:58:01
@article{4fcf1a97-04a2-4b5b-a581-6350ec2f2da2,
  abstract     = {{OBJECTIVE: To estimate the accuracy of endometrial thickness measurement in the detection of endometrial cancer among women with postmenopausal bleeding with individual patient data using different meta-analytic strategies. DATA SOURCES: Original data sets of studies detected after reviewing the included studies of three previous reviews on this subject. An additional literature search of published articles using MEDLINE databases was preformed from January 2000 to December 2006 to identify articles reporting on endometrial carcinoma and sonographic endometrial thickness measurement in women with postmenopausal bleeding. METHODS OF STUDY SELECTION: We identified 90 studies reporting on endometrial thickness measurements and endometrial carcinoma in women with postmenopausal bleeding. TABULATION, INTEGRATION, AND RESULTS: We contacted 79 primary investigators to obtain the individual patient data of their reported studies, of which 13 could provide data. Data on 2,896 patients, of which 259 had carcinoma, were included. Several approaches were used in the analyses of the acquired data. First, we performed receiver operator characteristics (ROC) analysis per study, resulting in a summary area under the ROC curve (AUC) calculated as a weighted mean of AUCs from original studies. Second, individual patient data were pooled and analyzed with ROC analyses irrespective of study with standardization of distributional differences across studies using multiples of the median and by random effects logistic regression. Finally, we also used a two-stage procedure, calculating sensitivities and specificities for each study and using the bivariate random effects model to estimate summary estimates for diagnostic accuracy. This resulted in rather comparable ROC curves with AUCs varying between 0.82 and 0.84 and summary estimates for sensitivity and specificity located along these curves. These curves indicated a lower AUC than previously reported meta-analyses using conventional techniques. CONCLUSION: Previous meta-analyses on endometrial thickness measurement probably have overestimated its diagnostic accuracy in the detection of endometrial carcinoma. We advise the use of cutoff level of 3 mm for exclusion of endometrial carcinoma in women with postmenopausal bleeding. (Obstet Gynecol 2010;116:160-7)}},
  author       = {{Timmermans, Anne and Opmeer, Brent C. and Khan, Khalid S. and Bachmann, Lucas M. and Epstein, Elisabeth and Clark, T. Justin and Gupta, Janesh K. and Bakour, Shagaf H. and van den Bosch, Thierry and van Doorn, Helena C. and Cameron, Sharon T. and Giusa, M. Gabriella and Dessole, Stefano and Dijkhuizen, F. Paul H. L. J. and ter Riet, Gerben and Mol, Ben W. J.}},
  issn         = {{1873-233X}},
  language     = {{eng}},
  number       = {{1}},
  pages        = {{160--167}},
  publisher    = {{Lippincott Williams & Wilkins}},
  series       = {{Obstetrics and Gynecology}},
  title        = {{Endometrial Thickness Measurement for Detecting Endometrial Cancer in Women With Postmenopausal Bleeding A Systematic Review and Meta-Analysis}},
  url          = {{http://dx.doi.org/10.1097/AOG.0b013e3181e3e7e8}},
  doi          = {{10.1097/AOG.0b013e3181e3e7e8}},
  volume       = {{116}},
  year         = {{2010}},
}