(1981) In Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment 181(1-3). p.221-226- Abstract
- By combining suitable water preconcentration techniques and Particle-Induced X-ray Emission analysis (PIXE), we have developed a procedure for multielemental sub-ppb water analysis. The preconcentration step consists of adsorbing the metals in the form of organic chelates onto activated carbon, which is pressed to a tablet and then analysed by PIXE. For very low concentrations and small volumes of water, a “mini-tablet” technique of sample preparation is employed. The versatility of the chelating-adsorption-PIXE procedure is demonstrated for several different kinds of water.
Please use this url to cite or link to this publication:
https://lup.lub.lu.se/record/1745060
- author
- Johansson, Eva-Marta and Akselsson, Roland LU
- organization
- publishing date
- 1981
- type
- Contribution to journal
- publication status
- published
- subject
- keywords
- PIXE, trace element analysis, water
- in
- Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
- volume
- 181
- issue
- 1-3
- pages
- 221 - 226
- publisher
- Elsevier
- external identifiers
-
- scopus:0018995801
- ISSN
- 0167-5087
- DOI
- 10.1016/0029-554X(81)90610-8
- language
- English
- LU publication?
- yes
- additional info
- The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Ergonomics and Aerosol Technology (011025002), Nuclear Physics (Faculty of Technology) (011013007)
- id
- 15c3abcd-0cf5-4ca4-be0a-2d7a431dfa40 (old id 1745060)
- date added to LUP
- 2016-04-01 17:04:37
- date last changed
- 2021-12-27 06:59:35
@article{15c3abcd-0cf5-4ca4-be0a-2d7a431dfa40, abstract = {{By combining suitable water preconcentration techniques and Particle-Induced X-ray Emission analysis (PIXE), we have developed a procedure for multielemental sub-ppb water analysis. The preconcentration step consists of adsorbing the metals in the form of organic chelates onto activated carbon, which is pressed to a tablet and then analysed by PIXE. For very low concentrations and small volumes of water, a “mini-tablet” technique of sample preparation is employed. The versatility of the chelating-adsorption-PIXE procedure is demonstrated for several different kinds of water.}}, author = {{Johansson, Eva-Marta and Akselsson, Roland}}, issn = {{0167-5087}}, keywords = {{PIXE; trace element analysis; water}}, language = {{eng}}, number = {{1-3}}, pages = {{221--226}}, publisher = {{Elsevier}}, series = {{Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment}}, title = {{A Chelating Agent - Activated Carbon - PIXE Procedure for Sub-ppb Analysis of Trace Elements in Water}}, url = {{http://dx.doi.org/10.1016/0029-554X(81)90610-8}}, doi = {{10.1016/0029-554X(81)90610-8}}, volume = {{181}}, year = {{1981}}, }