Simple ultrasound rules to distinguish between benign and malignant adnexal masses before surgery: prospective validation by IOTA group

Timmerman, Dirk ; Ameye, Lieveke ; Fischerova, Daniela ; Epstein, Elisabeth ; Melis, Gian Benedetto ; Guerriero, Stefano ; Van Holsbeke, Caroline ; Savelli, Luca ; Fruscio, Robert and Lissoni, Andrea Alberto , et al. (2010) In BMJ: British Medical Journal 341. p.6839-6839
Abstract
Objectives To prospectively assess the diagnostic performance of simple ultrasound rules to predict benignity/malignancy in an adnexal mass and to test the performance of the risk of malignancy index, two logistic regression models, and subjective assessment of ultrasonic findings by an experienced ultrasound examiner in adnexal masses for which the simple rules yield an inconclusive result. Design Prospective temporal and external validation of simple ultrasound rules to distinguish benign from malignant adnexal masses. The rules comprised five ultrasonic features (including shape, size, solidity, and results of colour Doppler examination) to predict a malignant tumour (M features) and five to predict a benign tumour (B features). If one... (More)
Objectives To prospectively assess the diagnostic performance of simple ultrasound rules to predict benignity/malignancy in an adnexal mass and to test the performance of the risk of malignancy index, two logistic regression models, and subjective assessment of ultrasonic findings by an experienced ultrasound examiner in adnexal masses for which the simple rules yield an inconclusive result. Design Prospective temporal and external validation of simple ultrasound rules to distinguish benign from malignant adnexal masses. The rules comprised five ultrasonic features (including shape, size, solidity, and results of colour Doppler examination) to predict a malignant tumour (M features) and five to predict a benign tumour (B features). If one or more M features were present in the absence of a B feature, the mass was classified as malignant. If one or more B features were present in the absence of an M feature, it was classified as benign. If both M features and B features were present, or if none of the features was present, the simple rules were inconclusive. Setting 19 ultrasound centres in eight countries. Participants 1938 women with an adnexal mass examined with ultrasound by the principal investigator at each centre with a standardised research protocol. Reference standard Histological classification of the excised adnexal mass as benign or malignant. Main outcome measures Diagnostic sensitivity and specificity. Results Of the 1938 patients with an adnexal mass, 1396 (72%) had benign tumours, 373 (19.2%) had primary invasive tumours, 111 (5.7%) had borderline malignant tumours, and 58 (3%) had metastatic tumours in the ovary. The simple rules yielded a conclusive result in 1501 (77%) masses, for which they resulted in a sensitivity of 92% (95% confidence interval 89% to 94%) and a specificity of 96% (94% to 97%). The corresponding sensitivity and specificity of subjective assessment were 91% (88% to 94%) and 96% (94% to 97%). In the 357 masses for which the simple rules yielded an inconclusive result and with available results of CA-125 measurements, the sensitivities were 89% (83% to 93%) for subjective assessment, 50% (42% to 58%) for the risk of malignancy index, 89% (83% to 93%) for logistic regression model 1, and 82% (75% to 87%) for logistic regression model 2; the corresponding specificities were 78% (72% to 83%), 84% (78% to 88%), 44% (38% to 51%), and 48% (42% to 55%). Use of the simple rules as a triage test and subjective assessment for those masses for which the simple rules yielded an inconclusive result gave a sensitivity of 91% (88% to 93%) and a specificity of 93% (91% to 94%), compared with a sensitivity of 90% (88% to 93%) and a specificity of 93% (91% to 94%) when subjective assessment was used in all masses. Conclusions The use of the simple rules has the potential to improve the management of women with adnexal masses. In adnexal masses for which the rules yielded an inconclusive result, subjective assessment of ultrasonic findings by an experienced ultrasound examiner was the most accurate diagnostic test; the risk of malignancy index and the two regression models were not useful. (Less)
Please use this url to cite or link to this publication:
author
; ; ; ; ; ; ; ; and , et al. (More)
; ; ; ; ; ; ; ; ; ; ; ; ; ; and (Less)
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
BMJ: British Medical Journal
volume
341
pages
6839 - 6839
publisher
BMJ Publishing Group
external identifiers
  • wos:000285552200013
  • scopus:78651401034
ISSN
1756-1833
DOI
10.1136/bmj.c6839
language
English
LU publication?
yes
id
c5ecc74c-3a3a-4cbb-94bd-da42f3a9dfc1 (old id 1773784)
date added to LUP
2016-04-01 09:49:31
date last changed
2022-01-25 17:01:31
@article{c5ecc74c-3a3a-4cbb-94bd-da42f3a9dfc1,
  abstract     = {{Objectives To prospectively assess the diagnostic performance of simple ultrasound rules to predict benignity/malignancy in an adnexal mass and to test the performance of the risk of malignancy index, two logistic regression models, and subjective assessment of ultrasonic findings by an experienced ultrasound examiner in adnexal masses for which the simple rules yield an inconclusive result. Design Prospective temporal and external validation of simple ultrasound rules to distinguish benign from malignant adnexal masses. The rules comprised five ultrasonic features (including shape, size, solidity, and results of colour Doppler examination) to predict a malignant tumour (M features) and five to predict a benign tumour (B features). If one or more M features were present in the absence of a B feature, the mass was classified as malignant. If one or more B features were present in the absence of an M feature, it was classified as benign. If both M features and B features were present, or if none of the features was present, the simple rules were inconclusive. Setting 19 ultrasound centres in eight countries. Participants 1938 women with an adnexal mass examined with ultrasound by the principal investigator at each centre with a standardised research protocol. Reference standard Histological classification of the excised adnexal mass as benign or malignant. Main outcome measures Diagnostic sensitivity and specificity. Results Of the 1938 patients with an adnexal mass, 1396 (72%) had benign tumours, 373 (19.2%) had primary invasive tumours, 111 (5.7%) had borderline malignant tumours, and 58 (3%) had metastatic tumours in the ovary. The simple rules yielded a conclusive result in 1501 (77%) masses, for which they resulted in a sensitivity of 92% (95% confidence interval 89% to 94%) and a specificity of 96% (94% to 97%). The corresponding sensitivity and specificity of subjective assessment were 91% (88% to 94%) and 96% (94% to 97%). In the 357 masses for which the simple rules yielded an inconclusive result and with available results of CA-125 measurements, the sensitivities were 89% (83% to 93%) for subjective assessment, 50% (42% to 58%) for the risk of malignancy index, 89% (83% to 93%) for logistic regression model 1, and 82% (75% to 87%) for logistic regression model 2; the corresponding specificities were 78% (72% to 83%), 84% (78% to 88%), 44% (38% to 51%), and 48% (42% to 55%). Use of the simple rules as a triage test and subjective assessment for those masses for which the simple rules yielded an inconclusive result gave a sensitivity of 91% (88% to 93%) and a specificity of 93% (91% to 94%), compared with a sensitivity of 90% (88% to 93%) and a specificity of 93% (91% to 94%) when subjective assessment was used in all masses. Conclusions The use of the simple rules has the potential to improve the management of women with adnexal masses. In adnexal masses for which the rules yielded an inconclusive result, subjective assessment of ultrasonic findings by an experienced ultrasound examiner was the most accurate diagnostic test; the risk of malignancy index and the two regression models were not useful.}},
  author       = {{Timmerman, Dirk and Ameye, Lieveke and Fischerova, Daniela and Epstein, Elisabeth and Melis, Gian Benedetto and Guerriero, Stefano and Van Holsbeke, Caroline and Savelli, Luca and Fruscio, Robert and Lissoni, Andrea Alberto and Testa, Antonia Carla and Veldman, Joan and Vergote, Ignace and Van Huffel, Sabine and Bourne, Tom and Valentin, Lil}},
  issn         = {{1756-1833}},
  language     = {{eng}},
  pages        = {{6839--6839}},
  publisher    = {{BMJ Publishing Group}},
  series       = {{BMJ: British Medical Journal}},
  title        = {{Simple ultrasound rules to distinguish between benign and malignant adnexal masses before surgery: prospective validation by IOTA group}},
  url          = {{http://dx.doi.org/10.1136/bmj.c6839}},
  doi          = {{10.1136/bmj.c6839}},
  volume       = {{341}},
  year         = {{2010}},
}