Phosphatidylethanol in blood (B-PEth): A marker for alcohol use and abuse.

Isaksson, Anders LU ; Walther, Lisa ; Hansson, Therese LU ; Andersson, Anders S LU and Alling, Christer LU (2011) In Drug Testing and Analysis 3. p.195-200
Abstract
Phosphatidylethanol (PEth) represents a group of glycerophospholipid homologues where ethanol by phospholipase D has been bound at the position that normally contains an amino-alcohol. Since the formation of PEth is specifically dependent on ethanol, the diagnostic specificity of PEth as an alcohol biomarker is theoretically 100%. The half-life of PEth in blood is approximately 4 days. The amount of alcohol consumed correlates to blood concentration of PEth and PEth has been shown to be a more sensitive indicator of alcohol consumption than traditional alcohol markers, such as CDT (carbohydrate-deficient transferrin), GGT (γ-glutamyl transferase), and MCV (mean corpuscular volume) or a combination of these. Almost all clinical data so far... (More)
Phosphatidylethanol (PEth) represents a group of glycerophospholipid homologues where ethanol by phospholipase D has been bound at the position that normally contains an amino-alcohol. Since the formation of PEth is specifically dependent on ethanol, the diagnostic specificity of PEth as an alcohol biomarker is theoretically 100%. The half-life of PEth in blood is approximately 4 days. The amount of alcohol consumed correlates to blood concentration of PEth and PEth has been shown to be a more sensitive indicator of alcohol consumption than traditional alcohol markers, such as CDT (carbohydrate-deficient transferrin), GGT (γ-glutamyl transferase), and MCV (mean corpuscular volume) or a combination of these. Almost all clinical data so far available are based on a high performance liquid chromatography (HPLC) method with limited analytical sensitivity. With the advent of methods with considerably higher analytical sensitivity (e.g. mass spectrometric methods), clinical sensitivity will increase correspondingly. The possibility of determining very low concentrations of PEth by new sensitive analytical techniques may, however, have both ethical and legal consequences that have to be considered. Copyright © 2011 John Wiley & Sons, Ltd. (Less)
Please use this url to cite or link to this publication:
author
; ; ; and
organization
publishing date
type
Contribution to journal
publication status
published
subject
in
Drug Testing and Analysis
volume
3
pages
195 - 200
publisher
Wiley-Blackwell
external identifiers
  • wos:000289639200001
  • pmid:21438164
  • scopus:79954792504
  • pmid:21438164
ISSN
1942-7611
DOI
10.1002/dta.278
language
English
LU publication?
yes
id
91f3d15b-d968-416b-9820-f78105660a1c (old id 1883442)
alternative location
http://www.ncbi.nlm.nih.gov/pubmed/21438164?dopt=Abstract
date added to LUP
2016-04-04 07:19:07
date last changed
2022-04-15 18:53:26
@article{91f3d15b-d968-416b-9820-f78105660a1c,
  abstract     = {{Phosphatidylethanol (PEth) represents a group of glycerophospholipid homologues where ethanol by phospholipase D has been bound at the position that normally contains an amino-alcohol. Since the formation of PEth is specifically dependent on ethanol, the diagnostic specificity of PEth as an alcohol biomarker is theoretically 100%. The half-life of PEth in blood is approximately 4 days. The amount of alcohol consumed correlates to blood concentration of PEth and PEth has been shown to be a more sensitive indicator of alcohol consumption than traditional alcohol markers, such as CDT (carbohydrate-deficient transferrin), GGT (γ-glutamyl transferase), and MCV (mean corpuscular volume) or a combination of these. Almost all clinical data so far available are based on a high performance liquid chromatography (HPLC) method with limited analytical sensitivity. With the advent of methods with considerably higher analytical sensitivity (e.g. mass spectrometric methods), clinical sensitivity will increase correspondingly. The possibility of determining very low concentrations of PEth by new sensitive analytical techniques may, however, have both ethical and legal consequences that have to be considered. Copyright © 2011 John Wiley & Sons, Ltd.}},
  author       = {{Isaksson, Anders and Walther, Lisa and Hansson, Therese and Andersson, Anders S and Alling, Christer}},
  issn         = {{1942-7611}},
  language     = {{eng}},
  pages        = {{195--200}},
  publisher    = {{Wiley-Blackwell}},
  series       = {{Drug Testing and Analysis}},
  title        = {{Phosphatidylethanol in blood (B-PEth): A marker for alcohol use and abuse.}},
  url          = {{http://dx.doi.org/10.1002/dta.278}},
  doi          = {{10.1002/dta.278}},
  volume       = {{3}},
  year         = {{2011}},
}