Abstract
Welding aerosols have been sampled in different size fractions using a moving stage cascade impactor. Sampling has been done for different welding methods and for varying welding parameters. The elemental composition of the different size fractions have been determined by Proton Induced X-ray Emission, PIXE, combined with a nuclear method for fluorine analysis.

Results show maximum mass of most elements to be on particles with an aerodynamic diameter in the range of 0.25-1µm.

Varying the welding parameter will affect distribution and chemical composition of the aerosols as well as the fume formation rate.
Please use this url to cite or link to this publication:
author
; and
organization
publishing date
type
Contribution to conference
publication status
unpublished
subject
keywords
PIXE, x-rays, gamma rays, welding aerosols
pages
26 pages
conference name
The American Industrial Hygiene Conference
conference location
Los Angeles, United States
conference dates
1978-05-07 - 1978-05-12
language
English
LU publication?
yes
additional info
The information about affiliations in this record was updated in December 2015. The record was previously connected to the following departments: Nuclear Physics (Faculty of Technology) (011013007), Ergonomics and Aerosol Technology (011025002), Division of Occupational and Environmental Medicine (013078001)
id
ed2f6fbe-6cd0-408c-ae29-13b178f2104e (old id 2205242)
date added to LUP
2016-04-04 14:13:04
date last changed
2018-11-21 21:19:00
@misc{ed2f6fbe-6cd0-408c-ae29-13b178f2104e,
  abstract     = {{Welding aerosols have been sampled in different size fractions using a moving stage cascade impactor. Sampling has been done for different welding methods and for varying welding parameters. The elemental composition of the different size fractions have been determined by Proton Induced X-ray Emission, PIXE, combined with a nuclear method for fluorine analysis.<br/><br>
Results show maximum mass of most elements to be on particles with an aerodynamic diameter in the range of 0.25-1µm.<br/><br>
Varying the welding parameter will affect distribution and chemical composition of the aerosols as well as the fume formation rate.}},
  author       = {{Malmqvist, Klas and Johansson, Gerd and Akselsson, Roland}},
  keywords     = {{PIXE; x-rays; gamma rays; welding aerosols}},
  language     = {{eng}},
  title        = {{Proton Induced X-rays and Gamma Rays for the Analysis of Welding Fumes}},
  url          = {{https://lup.lub.lu.se/search/files/6308388/2205243.pdf}},
  year         = {{1978}},
}